ABAP Select data from SAP table BICS_PROV_RFC_ADD_STRU_MEM_E into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BICS_PROV_RFC_ADD_STRU_MEM_E table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BICS_PROV_RFC_ADD_STRU_MEM_E. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BICS_PROV_RFC_ADD_STRU_MEM_E table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BICS_PROV_RFC_ADD_STRU_MEM_E TYPE STANDARD TABLE OF BICS_PROV_RFC_ADD_STRU_MEM_E,
      WA_BICS_PROV_RFC_ADD_STRU_MEM_E TYPE BICS_PROV_RFC_ADD_STRU_MEM_E,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BICS_PROV_RFC_ADD_STRU_MEM_E> TYPE BICS_PROV_RFC_ADD_STRU_MEM_E.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BICS_PROV_RFC_ADD_STRU_MEM_E.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BICS_PROV_RFC_ADD_STRU_MEM_E
  INTO TABLE IT_BICS_PROV_RFC_ADD_STRU_MEM_E.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BICS_PROV_RFC_ADD_STRU_MEM_E
*  INTO TABLE @DATA(IT_BICS_PROV_RFC_ADD_STRU_MEM_E2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BICS_PROV_RFC_ADD_STRU_MEM_E INDEX 1 INTO DATA(WA_BICS_PROV_RFC_ADD_STRU_MEM_E2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BICS_PROV_RFC_ADD_STRU_MEM_E ASSIGNING <BICS_PROV_RFC_ADD_STRU_MEM_E>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BICS_PROV_RFC_ADD_STRU_MEM_E>-E_MAX_MESSAGE_TYPE = 1.
<BICS_PROV_RFC_ADD_STRU_MEM_E>-E_MEMBER_ID = 1.
<BICS_PROV_RFC_ADD_STRU_MEM_E>-E_FORMULA_OK = 1.
<BICS_PROV_RFC_ADD_STRU_MEM_E>-E_T_DYN_KF = 1.
<BICS_PROV_RFC_ADD_STRU_MEM_E>-E_ELTUID = 1.
ENDLOOP.

LOOP AT IT_BICS_PROV_RFC_ADD_STRU_MEM_E INTO WA_BICS_PROV_RFC_ADD_STRU_MEM_E.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BICS_PROV_RFC_ADD_STRU_MEM_E-E_T_DATA_CELLS, sy-vline,
WA_BICS_PROV_RFC_ADD_STRU_MEM_E-ID, sy-vline,
WA_BICS_PROV_RFC_ADD_STRU_MEM_E-STRUCTURE_MEMBER_ID_1, sy-vline,
WA_BICS_PROV_RFC_ADD_STRU_MEM_E-STRUCTURE_MEMBER_ID_2, sy-vline,
WA_BICS_PROV_RFC_ADD_STRU_MEM_E-STRUCTURE_MEMBER_NAME_1, sy-vline,
WA_BICS_PROV_RFC_ADD_STRU_MEM_E-STRUCTURE_MEMBER_NAME_2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BICS_PROV_RFC_ADD_STRU_MEM_E you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BICS_PROV_RFC_ADD_STRU_MEM_E TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BICS_PROV_RFC_ADD_STRU_MEM_E INTO WA_BICS_PROV_RFC_ADD_STRU_MEM_E. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BICS_PROV_RFC_ADD_STRU_MEM_E_STR,
E_MAX_MESSAGE_TYPE TYPE STRING,
E_MEMBER_ID TYPE STRING,
E_FORMULA_OK TYPE STRING,
E_T_DYN_KF TYPE STRING,
E_ELTUID TYPE STRING,
E_T_DATA_CELLS TYPE STRING,
ID TYPE STRING,
STRUCTURE_MEMBER_ID_1 TYPE STRING,
STRUCTURE_MEMBER_ID_2 TYPE STRING,
STRUCTURE_MEMBER_NAME_1 TYPE STRING,
STRUCTURE_MEMBER_NAME_2 TYPE STRING,
STRUCTURE_MEMBER_ALT_NAME_1 TYPE STRING,
STRUCTURE_MEMBER_ALT_NAME_2 TYPE STRING,
STATIC TYPE STRING,
DFLT_PREC TYPE STRING,
DFLT_SCALE TYPE STRING,
SIGNINV TYPE STRING,
TCUR TYPE STRING,
SUMABLE TYPE STRING,
INPUT_ENABLED TYPE STRING,
MWKZ TYPE STRING,
AGGREGATION TYPE STRING,
EMPHASIZED TYPE STRING,
DISAGGR_KID TYPE STRING,
DISAGGR_MODE TYPE STRING,
BASED_ON_CHANMID TYPE STRING,
BASED_ON_CHANM TYPE STRING,
BASED_ON_CHA_F4_SUPPORT TYPE STRING,
WITH_CALCULATION TYPE STRING,
RESULT_CALCULATION TYPE STRING,
SINGLE_VALUE_CALCULATION TYPE STRING,
CUMULATION TYPE STRING,
HIDDEN TYPE STRING,
LOCAL_FORMULA TYPE STRING,
HAS_NO_CHECK_TABLE TYPE STRING,
SEMANTIC_OBJECT TYPE STRING,
E_FORMULA_NAME TYPE STRING,
E_T_DATA_FORMULA_CELLS TYPE STRING,
E_T_BW_OBJ TYPE STRING,END OF T_EKKO_STR. DATA: WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-E_MAX_MESSAGE_TYPE sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-E_MEMBER_ID sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-E_FORMULA_OK sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-E_T_DYN_KF sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-E_ELTUID sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-E_T_DATA_CELLS sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-ID sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-STRUCTURE_MEMBER_ID_1 sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-STRUCTURE_MEMBER_ID_2 sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-STRUCTURE_MEMBER_NAME_1 sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-STRUCTURE_MEMBER_NAME_2 sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-STRUCTURE_MEMBER_ALT_NAME_1 sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-STRUCTURE_MEMBER_ALT_NAME_2 sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-STATIC sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-DFLT_PREC sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-DFLT_SCALE sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-SIGNINV sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-TCUR sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-SUMABLE sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-INPUT_ENABLED sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-MWKZ sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-AGGREGATION sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-EMPHASIZED sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-DISAGGR_KID sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-DISAGGR_MODE sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-BASED_ON_CHANMID sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-BASED_ON_CHANM sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-BASED_ON_CHA_F4_SUPPORT sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-WITH_CALCULATION sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-RESULT_CALCULATION sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-SINGLE_VALUE_CALCULATION sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-CUMULATION sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-HIDDEN sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-LOCAL_FORMULA sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-HAS_NO_CHECK_TABLE sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-SEMANTIC_OBJECT sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-E_FORMULA_NAME sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-E_T_DATA_FORMULA_CELLS sy-vline
WA_BICS_PROV_RFC_ADD_STRU_MEM_E_STR-E_T_BW_OBJ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.