ABAP Select data from SAP table BGCHK_K into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BGCHK_K table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BGCHK_K. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BGCHK_K table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BGCHK_K TYPE STANDARD TABLE OF BGCHK_K,
      WA_BGCHK_K TYPE BGCHK_K,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BGCHK_K> TYPE BGCHK_K.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BGCHK_K.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BGCHK_K
  INTO TABLE IT_BGCHK_K.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BGCHK_K
*  INTO TABLE @DATA(IT_BGCHK_K2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BGCHK_K INDEX 1 INTO DATA(WA_BGCHK_K2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BGCHK_K ASSIGNING <BGCHK_K>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BGCHK_K>-OBJNR_GAR = 1.
<BGCHK_K>-OBJKT = 1.
<BGCHK_K>-OBJTX = 1.
<BGCHK_K>-RES_OBJEKT = 1.
<BGCHK_K>-AENKZ = 1.
ENDLOOP.

LOOP AT IT_BGCHK_K INTO WA_BGCHK_K.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BGCHK_K-PRTKZ, sy-vline,
WA_BGCHK_K-GAKTX, sy-vline,
WA_BGCHK_K-KZLTX, sy-vline,
WA_BGCHK_K-SPRAS, sy-vline,
WA_BGCHK_K-KZMLA, sy-vline,
WA_BGCHK_K-MANDT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BGCHK_K you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BGCHK_K TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BGCHK_K INTO WA_BGCHK_K. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_BGCHK_K-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BGCHK_K-SPRAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MGANR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BGCHK_K-MGANR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BGCHK_K-MGANR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_BGCHK_K-LANGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BGCHK_K-LANGE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BGCHK_K_STR,
OBJNR_GAR TYPE STRING,
OBJKT TYPE STRING,
OBJTX TYPE STRING,
RES_OBJEKT TYPE STRING,
AENKZ TYPE STRING,
PRTKZ TYPE STRING,
GAKTX TYPE STRING,
KZLTX TYPE STRING,
SPRAS TYPE STRING,
KZMLA TYPE STRING,
MANDT TYPE STRING,
MGANR TYPE STRING,
DATAB TYPE STRING,
DATBI TYPE STRING,
EXGAR TYPE STRING,
GASOR TYPE STRING,
GAGRP TYPE STRING,
ERDAT TYPE STRING,
ERZEI TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AEZEI TYPE STRING,
AENAM TYPE STRING,
BEGRU TYPE STRING,
LVORM TYPE STRING,
OBJNR TYPE STRING,
PARGR TYPE STRING,
GAART TYPE STRING,
LANGE TYPE STRING,
GAERB TYPE STRING,
VGLPA TYPE STRING,
RES_COUNT TYPE STRING,
RES_POS TYPE STRING,
RES_HEADR TYPE STRING,
RES_OBJECT TYPE STRING,END OF T_EKKO_STR. DATA: WA_BGCHK_K_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BGCHK_K_STR-OBJNR_GAR sy-vline
WA_BGCHK_K_STR-OBJKT sy-vline
WA_BGCHK_K_STR-OBJTX sy-vline
WA_BGCHK_K_STR-RES_OBJEKT sy-vline
WA_BGCHK_K_STR-AENKZ sy-vline
WA_BGCHK_K_STR-PRTKZ sy-vline
WA_BGCHK_K_STR-GAKTX sy-vline
WA_BGCHK_K_STR-KZLTX sy-vline
WA_BGCHK_K_STR-SPRAS sy-vline
WA_BGCHK_K_STR-KZMLA sy-vline
WA_BGCHK_K_STR-MANDT sy-vline
WA_BGCHK_K_STR-MGANR sy-vline
WA_BGCHK_K_STR-DATAB sy-vline
WA_BGCHK_K_STR-DATBI sy-vline
WA_BGCHK_K_STR-EXGAR sy-vline
WA_BGCHK_K_STR-GASOR sy-vline
WA_BGCHK_K_STR-GAGRP sy-vline
WA_BGCHK_K_STR-ERDAT sy-vline
WA_BGCHK_K_STR-ERZEI sy-vline
WA_BGCHK_K_STR-ERNAM sy-vline
WA_BGCHK_K_STR-AEDAT sy-vline
WA_BGCHK_K_STR-AEZEI sy-vline
WA_BGCHK_K_STR-AENAM sy-vline
WA_BGCHK_K_STR-BEGRU sy-vline
WA_BGCHK_K_STR-LVORM sy-vline
WA_BGCHK_K_STR-OBJNR sy-vline
WA_BGCHK_K_STR-PARGR sy-vline
WA_BGCHK_K_STR-GAART sy-vline
WA_BGCHK_K_STR-LANGE sy-vline
WA_BGCHK_K_STR-GAERB sy-vline
WA_BGCHK_K_STR-VGLPA sy-vline
WA_BGCHK_K_STR-RES_COUNT sy-vline
WA_BGCHK_K_STR-RES_POS sy-vline
WA_BGCHK_K_STR-RES_HEADR sy-vline
WA_BGCHK_K_STR-RES_OBJECT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.