ABAP Select data from SAP table BDLWLUSTCX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BDLWLUSTCX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BDLWLUSTCX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BDLWLUSTCX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BDLWLUSTCX TYPE STANDARD TABLE OF BDLWLUSTCX,
      WA_BDLWLUSTCX TYPE BDLWLUSTCX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BDLWLUSTCX> TYPE BDLWLUSTCX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BDLWLUSTCX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BDLWLUSTCX
  INTO TABLE IT_BDLWLUSTCX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BDLWLUSTCX
*  INTO TABLE @DATA(IT_BDLWLUSTCX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BDLWLUSTCX INDEX 1 INTO DATA(WA_BDLWLUSTCX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BDLWLUSTCX ASSIGNING <BDLWLUSTCX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BDLWLUSTCX>-DATE = 1.
<BDLWLUSTCX>-HOSTID = 1.
<BDLWLUSTCX>-TTYPE = 1.
<BDLWLUSTCX>-ACCOUNT = 1.
<BDLWLUSTCX>-ENTRY_ID = 1.
ENDLOOP.

LOOP AT IT_BDLWLUSTCX INTO WA_BDLWLUSTCX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BDLWLUSTCX-COUNT, sy-vline,
WA_BDLWLUSTCX-DCOUNT, sy-vline,
WA_BDLWLUSTCX-UCOUNT, sy-vline,
WA_BDLWLUSTCX-BCOUNT, sy-vline,
WA_BDLWLUSTCX-ECOUNT, sy-vline,
WA_BDLWLUSTCX-SCOUNT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BDLWLUSTCX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BDLWLUSTCX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BDLWLUSTCX INTO WA_BDLWLUSTCX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BDLWLUSTCX_STR,
DATE TYPE STRING,
HOSTID TYPE STRING,
TTYPE TYPE STRING,
ACCOUNT TYPE STRING,
ENTRY_ID TYPE STRING,
COUNT TYPE STRING,
DCOUNT TYPE STRING,
UCOUNT TYPE STRING,
BCOUNT TYPE STRING,
ECOUNT TYPE STRING,
SCOUNT TYPE STRING,
RESPTI TYPE STRING,
CPUTI TYPE STRING,
QUEUETI TYPE STRING,
READDIRCNT TYPE STRING,
READDIRTI TYPE STRING,
READDIRBUF TYPE STRING,
READSEQCNT TYPE STRING,
READSEQTI TYPE STRING,
PHYREADCNT TYPE STRING,
CHNGCNT TYPE STRING,
CHNGTI TYPE STRING,
PHYCHNGREC TYPE STRING,
DSQLCNT TYPE STRING,
QUECNT TYPE STRING,
CPICCNT TYPE STRING,
SLI_CNT TYPE STRING,
GUITIME TYPE STRING,
GUICNT TYPE STRING,
GUINETTIME TYPE STRING,
DBP_COUNT TYPE STRING,
DBP_TIME TYPE STRING,
LUW_COUNT TYPE STRING,
TMBYTESIN TYPE STRING,
TMBYTESOUT TYPE STRING,END OF T_EKKO_STR. DATA: WA_BDLWLUSTCX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BDLWLUSTCX_STR-DATE sy-vline
WA_BDLWLUSTCX_STR-HOSTID sy-vline
WA_BDLWLUSTCX_STR-TTYPE sy-vline
WA_BDLWLUSTCX_STR-ACCOUNT sy-vline
WA_BDLWLUSTCX_STR-ENTRY_ID sy-vline
WA_BDLWLUSTCX_STR-COUNT sy-vline
WA_BDLWLUSTCX_STR-DCOUNT sy-vline
WA_BDLWLUSTCX_STR-UCOUNT sy-vline
WA_BDLWLUSTCX_STR-BCOUNT sy-vline
WA_BDLWLUSTCX_STR-ECOUNT sy-vline
WA_BDLWLUSTCX_STR-SCOUNT sy-vline
WA_BDLWLUSTCX_STR-RESPTI sy-vline
WA_BDLWLUSTCX_STR-CPUTI sy-vline
WA_BDLWLUSTCX_STR-QUEUETI sy-vline
WA_BDLWLUSTCX_STR-READDIRCNT sy-vline
WA_BDLWLUSTCX_STR-READDIRTI sy-vline
WA_BDLWLUSTCX_STR-READDIRBUF sy-vline
WA_BDLWLUSTCX_STR-READSEQCNT sy-vline
WA_BDLWLUSTCX_STR-READSEQTI sy-vline
WA_BDLWLUSTCX_STR-PHYREADCNT sy-vline
WA_BDLWLUSTCX_STR-CHNGCNT sy-vline
WA_BDLWLUSTCX_STR-CHNGTI sy-vline
WA_BDLWLUSTCX_STR-PHYCHNGREC sy-vline
WA_BDLWLUSTCX_STR-DSQLCNT sy-vline
WA_BDLWLUSTCX_STR-QUECNT sy-vline
WA_BDLWLUSTCX_STR-CPICCNT sy-vline
WA_BDLWLUSTCX_STR-SLI_CNT sy-vline
WA_BDLWLUSTCX_STR-GUITIME sy-vline
WA_BDLWLUSTCX_STR-GUICNT sy-vline
WA_BDLWLUSTCX_STR-GUINETTIME sy-vline
WA_BDLWLUSTCX_STR-DBP_COUNT sy-vline
WA_BDLWLUSTCX_STR-DBP_TIME sy-vline
WA_BDLWLUSTCX_STR-LUW_COUNT sy-vline
WA_BDLWLUSTCX_STR-TMBYTESIN sy-vline
WA_BDLWLUSTCX_STR-TMBYTESOUT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.