ABAP Select data from SAP table BBP_PDS_BUP_ICOM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BBP_PDS_BUP_ICOM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BBP_PDS_BUP_ICOM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BBP_PDS_BUP_ICOM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BBP_PDS_BUP_ICOM TYPE STANDARD TABLE OF BBP_PDS_BUP_ICOM,
      WA_BBP_PDS_BUP_ICOM TYPE BBP_PDS_BUP_ICOM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BBP_PDS_BUP_ICOM> TYPE BBP_PDS_BUP_ICOM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BBP_PDS_BUP_ICOM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BBP_PDS_BUP_ICOM
  INTO TABLE IT_BBP_PDS_BUP_ICOM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BBP_PDS_BUP_ICOM
*  INTO TABLE @DATA(IT_BBP_PDS_BUP_ICOM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BBP_PDS_BUP_ICOM INDEX 1 INTO DATA(WA_BBP_PDS_BUP_ICOM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BBP_PDS_BUP_ICOM ASSIGNING <BBP_PDS_BUP_ICOM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BBP_PDS_BUP_ICOM>-OBJECT_TYPE = 1.
<BBP_PDS_BUP_ICOM>-PROC_ORG_OT = 1.
<BBP_PDS_BUP_ICOM>-PROC_ORG_ID = 1.
<BBP_PDS_BUP_ICOM>-EV_ORG_CHANGED = 1.
<BBP_PDS_BUP_ICOM>-BE_LOG_SYSTEM = 1.
ENDLOOP.

LOOP AT IT_BBP_PDS_BUP_ICOM INTO WA_BBP_PDS_BUP_ICOM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BBP_PDS_BUP_ICOM-BE_PUR_ORG, sy-vline,
WA_BBP_PDS_BUP_ICOM-PROC_TYPE, sy-vline,
WA_BBP_PDS_BUP_ICOM-SUBTYPE, sy-vline,
WA_BBP_PDS_BUP_ICOM-SUBTYPE_I, sy-vline,
WA_BBP_PDS_BUP_ICOM-TEMPLATE_TYPE, sy-vline,
WA_BBP_PDS_BUP_ICOM-LOGSYS_FI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BBP_PDS_BUP_ICOM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BBP_PDS_BUP_ICOM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BBP_PDS_BUP_ICOM INTO WA_BBP_PDS_BUP_ICOM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BE_LOG_SYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BBP_PDS_BUP_ICOM-BE_LOG_SYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BBP_PDS_BUP_ICOM-BE_LOG_SYSTEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS_FI CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BBP_PDS_BUP_ICOM-LOGSYS_FI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BBP_PDS_BUP_ICOM-LOGSYS_FI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COMPANY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BBP_PDS_BUP_ICOM-COMPANY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BBP_PDS_BUP_ICOM-COMPANY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BBP_PDS_BUP_ICOM_STR,
OBJECT_TYPE TYPE STRING,
PROC_ORG_OT TYPE STRING,
PROC_ORG_ID TYPE STRING,
EV_ORG_CHANGED TYPE STRING,
BE_LOG_SYSTEM TYPE STRING,
BE_PUR_ORG TYPE STRING,
PROC_TYPE TYPE STRING,
SUBTYPE TYPE STRING,
SUBTYPE_I TYPE STRING,
TEMPLATE_TYPE TYPE STRING,
LOGSYS_FI TYPE STRING,
INV_KIND TYPE STRING,
COMPANY TYPE STRING,
VENDOR TYPE STRING,
EV_DEL_SOS TYPE STRING,
EV_RECIPIENT_CHANGED TYPE STRING,
EV_REQUESTOR_CHANGED TYPE STRING,
EV_SHIP_TO_CHANGED TYPE STRING,
EV_SHIP_FROM_CHANGED TYPE STRING,
EV_CONTACT_CHANGED TYPE STRING,
EV_LOCATION_CHANGED TYPE STRING,
EV_SERVICE_PROVIDER_CHANGED TYPE STRING,
EV_BILL_FROM_CONT_CHANGED TYPE STRING,
EV_CALL_OFF_CHANGED TYPE STRING,
EV_CUST_PARTNER1_CHANGED TYPE STRING,
EV_CUST_PARTNER2_CHANGED TYPE STRING,
EV_CUST_PARTNER3_CHANGED TYPE STRING,
EV_CUST_PARTNER_EMPL_CHANGED TYPE STRING,
EV_CUST_PART_CONT_CHANGED TYPE STRING,
ITM_TYPE TYPE STRING,
HEADER_GUID TYPE STRING,
BID_TYPE TYPE STRING,
RFQ_IND TYPE STRING,
BASIC_CHECK_ONLY TYPE STRING,
LUMP_SUM_IND TYPE STRING,
PS_CTRL_KEY TYPE STRING,
PS_IPT TYPE STRING,
PS_IDC_TYPE TYPE STRING,
OPT_IND TYPE STRING,
OPT_STATUS TYPE STRING,
PS_GUARANT_MIN TYPE STRING,
PS_PA_NSP_IND TYPE STRING,
PS_GM_NO_EMF TYPE STRING,END OF T_EKKO_STR. DATA: WA_BBP_PDS_BUP_ICOM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BBP_PDS_BUP_ICOM_STR-OBJECT_TYPE sy-vline
WA_BBP_PDS_BUP_ICOM_STR-PROC_ORG_OT sy-vline
WA_BBP_PDS_BUP_ICOM_STR-PROC_ORG_ID sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_ORG_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-BE_LOG_SYSTEM sy-vline
WA_BBP_PDS_BUP_ICOM_STR-BE_PUR_ORG sy-vline
WA_BBP_PDS_BUP_ICOM_STR-PROC_TYPE sy-vline
WA_BBP_PDS_BUP_ICOM_STR-SUBTYPE sy-vline
WA_BBP_PDS_BUP_ICOM_STR-SUBTYPE_I sy-vline
WA_BBP_PDS_BUP_ICOM_STR-TEMPLATE_TYPE sy-vline
WA_BBP_PDS_BUP_ICOM_STR-LOGSYS_FI sy-vline
WA_BBP_PDS_BUP_ICOM_STR-INV_KIND sy-vline
WA_BBP_PDS_BUP_ICOM_STR-COMPANY sy-vline
WA_BBP_PDS_BUP_ICOM_STR-VENDOR sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_DEL_SOS sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_RECIPIENT_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_REQUESTOR_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_SHIP_TO_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_SHIP_FROM_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_CONTACT_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_LOCATION_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_SERVICE_PROVIDER_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_BILL_FROM_CONT_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_CALL_OFF_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_CUST_PARTNER1_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_CUST_PARTNER2_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_CUST_PARTNER3_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_CUST_PARTNER_EMPL_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-EV_CUST_PART_CONT_CHANGED sy-vline
WA_BBP_PDS_BUP_ICOM_STR-ITM_TYPE sy-vline
WA_BBP_PDS_BUP_ICOM_STR-HEADER_GUID sy-vline
WA_BBP_PDS_BUP_ICOM_STR-BID_TYPE sy-vline
WA_BBP_PDS_BUP_ICOM_STR-RFQ_IND sy-vline
WA_BBP_PDS_BUP_ICOM_STR-BASIC_CHECK_ONLY sy-vline
WA_BBP_PDS_BUP_ICOM_STR-LUMP_SUM_IND sy-vline
WA_BBP_PDS_BUP_ICOM_STR-PS_CTRL_KEY sy-vline
WA_BBP_PDS_BUP_ICOM_STR-PS_IPT sy-vline
WA_BBP_PDS_BUP_ICOM_STR-PS_IDC_TYPE sy-vline
WA_BBP_PDS_BUP_ICOM_STR-OPT_IND sy-vline
WA_BBP_PDS_BUP_ICOM_STR-OPT_STATUS sy-vline
WA_BBP_PDS_BUP_ICOM_STR-PS_GUARANT_MIN sy-vline
WA_BBP_PDS_BUP_ICOM_STR-PS_PA_NSP_IND sy-vline
WA_BBP_PDS_BUP_ICOM_STR-PS_GM_NO_EMF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.