ABAP Select data from SAP table BAPILFCONDC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BAPILFCONDC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BAPILFCONDC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BAPILFCONDC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BAPILFCONDC TYPE STANDARD TABLE OF BAPILFCONDC,
      WA_BAPILFCONDC TYPE BAPILFCONDC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BAPILFCONDC> TYPE BAPILFCONDC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BAPILFCONDC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BAPILFCONDC
  INTO TABLE IT_BAPILFCONDC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BAPILFCONDC
*  INTO TABLE @DATA(IT_BAPILFCONDC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BAPILFCONDC INDEX 1 INTO DATA(WA_BAPILFCONDC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BAPILFCONDC ASSIGNING <BAPILFCONDC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BAPILFCONDC>-DOCUMENT_NUMBER = 1.
<BAPILFCONDC>-ITEM = 1.
<BAPILFCONDC>-COND_ST_NO = 1.
<BAPILFCONDC>-COND_COUNT = 1.
<BAPILFCONDC>-COND_TYPE = 1.
ENDLOOP.

LOOP AT IT_BAPILFCONDC INTO WA_BAPILFCONDC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BAPILFCONDC-COND_VALUE, sy-vline,
WA_BAPILFCONDC-CURRENCY, sy-vline,
WA_BAPILFCONDC-CURR_ISO, sy-vline,
WA_BAPILFCONDC-COND_UNIT, sy-vline,
WA_BAPILFCONDC-CD_UNT_ISO, sy-vline,
WA_BAPILFCONDC-COND_P_UNT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BAPILFCONDC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BAPILFCONDC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BAPILFCONDC INTO WA_BAPILFCONDC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field DOCUMENT_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BAPILFCONDC-DOCUMENT_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BAPILFCONDC-DOCUMENT_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field COND_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_BAPILFCONDC-COND_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BAPILFCONDC-COND_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field CONEXCHRAT CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_BAPILFCONDC-CONEXCHRAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BAPILFCONDC-CONEXCHRAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNITMEASUR CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_BAPILFCONDC-UNITMEASUR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BAPILFCONDC-UNITMEASUR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BAPILFCONDC_STR,
DOCUMENT_NUMBER TYPE STRING,
ITEM TYPE STRING,
COND_ST_NO TYPE STRING,
COND_COUNT TYPE STRING,
COND_TYPE TYPE STRING,
COND_VALUE TYPE STRING,
CURRENCY TYPE STRING,
CURR_ISO TYPE STRING,
COND_UNIT TYPE STRING,
CD_UNT_ISO TYPE STRING,
COND_P_UNT TYPE STRING,
UPDATEFLAG TYPE STRING,
COND_BASE TYPE STRING,
APPLICATIO TYPE STRING,
CONPRICDAT TYPE STRING,
CALCTYPCON TYPE STRING,
CONBASEVAL TYPE STRING,
CONEXCHRAT TYPE STRING,
NUMCONVERT TYPE STRING,
DENOMINATO TYPE STRING,
CONDTYPE TYPE STRING,
STAT_CON TYPE STRING,
SCALETYPE TYPE STRING,
ACCRUALS TYPE STRING,
CONINVOLST TYPE STRING,
CONDORIGIN TYPE STRING,
CONDISACTI TYPE STRING,
CONDCLASS TYPE STRING,
SCALEBASIN TYPE STRING,
SCALEBASE TYPE STRING,
UNITMEASUR TYPE STRING,
ISO_UNIT TYPE STRING,
CURRENCKEY TYPE STRING,
CURRENISO TYPE STRING,
ACCESS_SEQ TYPE STRING,
CONDCNTRL TYPE STRING,
ACCESS_SEQ_LONG TYPE STRING,
COND_COUNT_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_BAPILFCONDC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BAPILFCONDC_STR-DOCUMENT_NUMBER sy-vline
WA_BAPILFCONDC_STR-ITEM sy-vline
WA_BAPILFCONDC_STR-COND_ST_NO sy-vline
WA_BAPILFCONDC_STR-COND_COUNT sy-vline
WA_BAPILFCONDC_STR-COND_TYPE sy-vline
WA_BAPILFCONDC_STR-COND_VALUE sy-vline
WA_BAPILFCONDC_STR-CURRENCY sy-vline
WA_BAPILFCONDC_STR-CURR_ISO sy-vline
WA_BAPILFCONDC_STR-COND_UNIT sy-vline
WA_BAPILFCONDC_STR-CD_UNT_ISO sy-vline
WA_BAPILFCONDC_STR-COND_P_UNT sy-vline
WA_BAPILFCONDC_STR-UPDATEFLAG sy-vline
WA_BAPILFCONDC_STR-COND_BASE sy-vline
WA_BAPILFCONDC_STR-APPLICATIO sy-vline
WA_BAPILFCONDC_STR-CONPRICDAT sy-vline
WA_BAPILFCONDC_STR-CALCTYPCON sy-vline
WA_BAPILFCONDC_STR-CONBASEVAL sy-vline
WA_BAPILFCONDC_STR-CONEXCHRAT sy-vline
WA_BAPILFCONDC_STR-NUMCONVERT sy-vline
WA_BAPILFCONDC_STR-DENOMINATO sy-vline
WA_BAPILFCONDC_STR-CONDTYPE sy-vline
WA_BAPILFCONDC_STR-STAT_CON sy-vline
WA_BAPILFCONDC_STR-SCALETYPE sy-vline
WA_BAPILFCONDC_STR-ACCRUALS sy-vline
WA_BAPILFCONDC_STR-CONINVOLST sy-vline
WA_BAPILFCONDC_STR-CONDORIGIN sy-vline
WA_BAPILFCONDC_STR-CONDISACTI sy-vline
WA_BAPILFCONDC_STR-CONDCLASS sy-vline
WA_BAPILFCONDC_STR-SCALEBASIN sy-vline
WA_BAPILFCONDC_STR-SCALEBASE sy-vline
WA_BAPILFCONDC_STR-UNITMEASUR sy-vline
WA_BAPILFCONDC_STR-ISO_UNIT sy-vline
WA_BAPILFCONDC_STR-CURRENCKEY sy-vline
WA_BAPILFCONDC_STR-CURRENISO sy-vline
WA_BAPILFCONDC_STR-ACCESS_SEQ sy-vline
WA_BAPILFCONDC_STR-CONDCNTRL sy-vline
WA_BAPILFCONDC_STR-ACCESS_SEQ_LONG sy-vline
WA_BAPILFCONDC_STR-COND_COUNT_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.