ABAP Select data from SAP table BAPICMS_STR_LIQ_MEASURE_GET into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BAPICMS_STR_LIQ_MEASURE_GET table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BAPICMS_STR_LIQ_MEASURE_GET. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BAPICMS_STR_LIQ_MEASURE_GET table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BAPICMS_STR_LIQ_MEASURE_GET TYPE STANDARD TABLE OF BAPICMS_STR_LIQ_MEASURE_GET,
      WA_BAPICMS_STR_LIQ_MEASURE_GET TYPE BAPICMS_STR_LIQ_MEASURE_GET,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BAPICMS_STR_LIQ_MEASURE_GET> TYPE BAPICMS_STR_LIQ_MEASURE_GET.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BAPICMS_STR_LIQ_MEASURE_GET.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BAPICMS_STR_LIQ_MEASURE_GET
  INTO TABLE IT_BAPICMS_STR_LIQ_MEASURE_GET.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BAPICMS_STR_LIQ_MEASURE_GET
*  INTO TABLE @DATA(IT_BAPICMS_STR_LIQ_MEASURE_GET2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BAPICMS_STR_LIQ_MEASURE_GET INDEX 1 INTO DATA(WA_BAPICMS_STR_LIQ_MEASURE_GET2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BAPICMS_STR_LIQ_MEASURE_GET ASSIGNING <BAPICMS_STR_LIQ_MEASURE_GET>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BAPICMS_STR_LIQ_MEASURE_GET>-LIQ_GUID = 1.
<BAPICMS_STR_LIQ_MEASURE_GET>-LIQ_TYP = 1.
<BAPICMS_STR_LIQ_MEASURE_GET>-LIQ_START_DATE = 1.
<BAPICMS_STR_LIQ_MEASURE_GET>-LIQ_END_DATE = 1.
<BAPICMS_STR_LIQ_MEASURE_GET>-ORDER_DATE = 1.
ENDLOOP.

LOOP AT IT_BAPICMS_STR_LIQ_MEASURE_GET INTO WA_BAPICMS_STR_LIQ_MEASURE_GET.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BAPICMS_STR_LIQ_MEASURE_GET-ORDER_RCVD_ON, sy-vline,
WA_BAPICMS_STR_LIQ_MEASURE_GET-CLOSE_DCSN_DATE, sy-vline,
WA_BAPICMS_STR_LIQ_MEASURE_GET-CLOSE_DN_RCVD_ON, sy-vline,
WA_BAPICMS_STR_LIQ_MEASURE_GET-LIQ_INI_BY, sy-vline,
WA_BAPICMS_STR_LIQ_MEASURE_GET-APPLN_DATE, sy-vline,
WA_BAPICMS_STR_LIQ_MEASURE_GET-CALL_GUAR_AMT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BAPICMS_STR_LIQ_MEASURE_GET you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BAPICMS_STR_LIQ_MEASURE_GET TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BAPICMS_STR_LIQ_MEASURE_GET INTO WA_BAPICMS_STR_LIQ_MEASURE_GET. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BAPICMS_STR_LIQ_MEASURE_GET_STR,
LIQ_GUID TYPE STRING,
LIQ_TYP TYPE STRING,
LIQ_START_DATE TYPE STRING,
LIQ_END_DATE TYPE STRING,
ORDER_DATE TYPE STRING,
ORDER_RCVD_ON TYPE STRING,
CLOSE_DCSN_DATE TYPE STRING,
CLOSE_DN_RCVD_ON TYPE STRING,
LIQ_INI_BY TYPE STRING,
APPLN_DATE TYPE STRING,
CALL_GUAR_AMT TYPE STRING,
CALL_GUAR_CURR TYPE STRING,
CALL_GUAR_CURR_ISO TYPE STRING,
CALL_DATE_GUAR TYPE STRING,
ENFC_DATE_GUAR TYPE STRING,
ENFC_OBTAIN_IND TYPE STRING,
ENFC_TITLE_DESC TYPE STRING,
AFFIDAVIT_DATE TYPE STRING,
AFFIDAVIT_DESC TYPE STRING,
AMICABLE_DATE TYPE STRING,
AMICABLE_DESC TYPE STRING,
REG_DATE TYPE STRING,
REQ_DATE TYPE STRING,
ATTCMT_DATE TYPE STRING,
TITLE_REQ_BEFORE TYPE STRING,
SETTLEMENT_DATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_BAPICMS_STR_LIQ_MEASURE_GET_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-LIQ_GUID sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-LIQ_TYP sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-LIQ_START_DATE sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-LIQ_END_DATE sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-ORDER_DATE sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-ORDER_RCVD_ON sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-CLOSE_DCSN_DATE sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-CLOSE_DN_RCVD_ON sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-LIQ_INI_BY sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-APPLN_DATE sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-CALL_GUAR_AMT sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-CALL_GUAR_CURR sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-CALL_GUAR_CURR_ISO sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-CALL_DATE_GUAR sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-ENFC_DATE_GUAR sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-ENFC_OBTAIN_IND sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-ENFC_TITLE_DESC sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-AFFIDAVIT_DATE sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-AFFIDAVIT_DESC sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-AMICABLE_DATE sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-AMICABLE_DESC sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-REG_DATE sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-REQ_DATE sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-ATTCMT_DATE sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-TITLE_REQ_BEFORE sy-vline
WA_BAPICMS_STR_LIQ_MEASURE_GET_STR-SETTLEMENT_DATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.