ABAP Select data from SAP table BAPI6109BTCH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BAPI6109BTCH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BAPI6109BTCH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BAPI6109BTCH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BAPI6109BTCH TYPE STANDARD TABLE OF BAPI6109BTCH,
      WA_BAPI6109BTCH TYPE BAPI6109BTCH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BAPI6109BTCH> TYPE BAPI6109BTCH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BAPI6109BTCH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BAPI6109BTCH
  INTO TABLE IT_BAPI6109BTCH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BAPI6109BTCH
*  INTO TABLE @DATA(IT_BAPI6109BTCH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BAPI6109BTCH INDEX 1 INTO DATA(WA_BAPI6109BTCH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BAPI6109BTCH ASSIGNING <BAPI6109BTCH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BAPI6109BTCH>-STARTDTTYP = 1.
<BAPI6109BTCH>-SDLSTRTDT = 1.
<BAPI6109BTCH>-SDLSTRTTM = 1.
<BAPI6109BTCH>-EVENTID = 1.
<BAPI6109BTCH>-EVENTPARM = 1.
ENDLOOP.

LOOP AT IT_BAPI6109BTCH INTO WA_BAPI6109BTCH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BAPI6109BTCH-PERIODIC, sy-vline,
WA_BAPI6109BTCH-CANCELPERIOD, sy-vline,
WA_BAPI6109BTCH-EVENT_ID_OK, sy-vline,
WA_BAPI6109BTCH-EVENT_PM_OK, sy-vline,
WA_BAPI6109BTCH-EVENT_ID_ER, sy-vline,
WA_BAPI6109BTCH-EVENT_PM_ER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BAPI6109BTCH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BAPI6109BTCH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BAPI6109BTCH INTO WA_BAPI6109BTCH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BAPI6109BTCH_STR,
STARTDTTYP TYPE STRING,
SDLSTRTDT TYPE STRING,
SDLSTRTTM TYPE STRING,
EVENTID TYPE STRING,
EVENTPARM TYPE STRING,
PERIODIC TYPE STRING,
CANCELPERIOD TYPE STRING,
EVENT_ID_OK TYPE STRING,
EVENT_PM_OK TYPE STRING,
EVENT_ID_ER TYPE STRING,
EVENT_PM_ER TYPE STRING,
FUNCTION_CALL TYPE STRING,
EXIT_CALL TYPE STRING,
BATCH_WAIT TYPE STRING,
JOBNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_BAPI6109BTCH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BAPI6109BTCH_STR-STARTDTTYP sy-vline
WA_BAPI6109BTCH_STR-SDLSTRTDT sy-vline
WA_BAPI6109BTCH_STR-SDLSTRTTM sy-vline
WA_BAPI6109BTCH_STR-EVENTID sy-vline
WA_BAPI6109BTCH_STR-EVENTPARM sy-vline
WA_BAPI6109BTCH_STR-PERIODIC sy-vline
WA_BAPI6109BTCH_STR-CANCELPERIOD sy-vline
WA_BAPI6109BTCH_STR-EVENT_ID_OK sy-vline
WA_BAPI6109BTCH_STR-EVENT_PM_OK sy-vline
WA_BAPI6109BTCH_STR-EVENT_ID_ER sy-vline
WA_BAPI6109BTCH_STR-EVENT_PM_ER sy-vline
WA_BAPI6109BTCH_STR-FUNCTION_CALL sy-vline
WA_BAPI6109BTCH_STR-EXIT_CALL sy-vline
WA_BAPI6109BTCH_STR-BATCH_WAIT sy-vline
WA_BAPI6109BTCH_STR-JOBNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.