ABAP Select data from SAP table BAPI6032_MESS into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP BAPI6032_MESS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BAPI6032_MESS. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the BAPI6032_MESS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_BAPI6032_MESS TYPE STANDARD TABLE OF BAPI6032_MESS,
WA_BAPI6032_MESS TYPE BAPI6032_MESS,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BAPI6032_MESS> TYPE BAPI6032_MESS.
*Process all fields in table header/work area as string values
PERFORM process_as_string_field_values CHANGING wa_BAPI6032_MESS.
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM BAPI6032_MESS
INTO TABLE IT_BAPI6032_MESS.
*Select data and declare internal table using in-line method @DATA
*SELECT *
* FROM BAPI6032_MESS
* INTO TABLE @DATA(IT_BAPI6032_MESS2).
*--Further methods of using ABAP code to select data from SAP database tables
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BAPI6032_MESS INDEX 1 INTO DATA(WA_BAPI6032_MESS2).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BAPI6032_MESS ASSIGNING <BAPI6032_MESS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<BAPI6032_MESS>-WGSREQN = 1.
<BAPI6032_MESS>-WGSREQP = 1.
<BAPI6032_MESS>-WGSREQF = 1.
<BAPI6032_MESS>-MSGNO = 1.
<BAPI6032_MESS>-MSGID = 1.
ENDLOOP. LOOP AT IT_BAPI6032_MESS INTO WA_BAPI6032_MESS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_BAPI6032_MESS-MSGTY, sy-vline,
WA_BAPI6032_MESS-PARAMETER1, sy-vline,
WA_BAPI6032_MESS-PARAMETER2, sy-vline,
WA_BAPI6032_MESS-PARAMETER3, sy-vline,
WA_BAPI6032_MESS-PARAMETER4, sy-vline,
WA_BAPI6032_MESS-WF_REFNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BAPI6032_MESS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BAPI6032_MESS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BAPI6032_MESS INTO WA_BAPI6032_MESS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field WGSREQN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BAPI6032_MESS-WGSREQN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BAPI6032_MESS-WGSREQN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BAPI6032_MESS_STR,
WGSREQN TYPE STRING,
WGSREQP TYPE STRING,
WGSREQF TYPE STRING,
MSGNO TYPE STRING,
MSGID TYPE STRING,
MSGTY TYPE STRING,
PARAMETER1 TYPE STRING,
PARAMETER2 TYPE STRING,
PARAMETER3 TYPE STRING,
PARAMETER4 TYPE STRING,
WF_REFNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_BAPI6032_MESS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BAPI6032_MESS_STR-WGSREQN sy-vline
WA_BAPI6032_MESS_STR-WGSREQP sy-vline
WA_BAPI6032_MESS_STR-WGSREQF sy-vline
WA_BAPI6032_MESS_STR-MSGNO sy-vline
WA_BAPI6032_MESS_STR-MSGID sy-vline
WA_BAPI6032_MESS_STR-MSGTY sy-vline
WA_BAPI6032_MESS_STR-PARAMETER1 sy-vline
WA_BAPI6032_MESS_STR-PARAMETER2 sy-vline
WA_BAPI6032_MESS_STR-PARAMETER3 sy-vline
WA_BAPI6032_MESS_STR-PARAMETER4 sy-vline
WA_BAPI6032_MESS_STR-WF_REFNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.
