ABAP Select data from SAP table BAPI1176_CMP_NODEDATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP BAPI1176_CMP_NODEDATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BAPI1176_CMP_NODEDATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the BAPI1176_CMP_NODEDATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_BAPI1176_CMP_NODEDATA TYPE STANDARD TABLE OF BAPI1176_CMP_NODEDATA, WA_BAPI1176_CMP_NODEDATA TYPE BAPI1176_CMP_NODEDATA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <BAPI1176_CMP_NODEDATA> TYPE BAPI1176_CMP_NODEDATA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_BAPI1176_CMP_NODEDATA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM BAPI1176_CMP_NODEDATA INTO TABLE IT_BAPI1176_CMP_NODEDATA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM BAPI1176_CMP_NODEDATA * INTO TABLE @DATA(IT_BAPI1176_CMP_NODEDATA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_BAPI1176_CMP_NODEDATA INDEX 1 INTO DATA(WA_BAPI1176_CMP_NODEDATA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_BAPI1176_CMP_NODEDATA ASSIGNING <BAPI1176_CMP_NODEDATA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<BAPI1176_CMP_NODEDATA>-NODE_ID = 1.
<BAPI1176_CMP_NODEDATA>-NODE_NAME = 1.
<BAPI1176_CMP_NODEDATA>-CLASS_NUM = 1.
<BAPI1176_CMP_NODEDATA>-CLASS_TYPE = 1.
<BAPI1176_CMP_NODEDATA>-NODE_TYPE = 1.
ENDLOOP. LOOP AT IT_BAPI1176_CMP_NODEDATA INTO WA_BAPI1176_CMP_NODEDATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_BAPI1176_CMP_NODEDATA-DELETE_FLG, sy-vline,
WA_BAPI1176_CMP_NODEDATA-SELECT_MANDATORY, sy-vline,
WA_BAPI1176_CMP_NODEDATA-SELECT_MULTIPLE, sy-vline,
WA_BAPI1176_CMP_NODEDATA-FREE_POSITIONS, sy-vline,
WA_BAPI1176_CMP_NODEDATA-EVALUATION_PRIORITY, sy-vline,
WA_BAPI1176_CMP_NODEDATA-LOG_SYSTEM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BAPI1176_CMP_NODEDATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BAPI1176_CMP_NODEDATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BAPI1176_CMP_NODEDATA INTO WA_BAPI1176_CMP_NODEDATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit PNUID, internal->external for field NODE_ID CALL FUNCTION 'CONVERSION_EXIT_PNUID_OUTPUT' EXPORTING input = WA_BAPI1176_CMP_NODEDATA-NODE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BAPI1176_CMP_NODEDATA-NODE_ID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LOG_SYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_BAPI1176_CMP_NODEDATA-LOG_SYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BAPI1176_CMP_NODEDATA-LOG_SYSTEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BAPI1176_CMP_NODEDATA_STR,
NODE_ID TYPE STRING,
NODE_NAME TYPE STRING,
CLASS_NUM TYPE STRING,
CLASS_TYPE TYPE STRING,
NODE_TYPE TYPE STRING,
DELETE_FLG TYPE STRING,
SELECT_MANDATORY TYPE STRING,
SELECT_MULTIPLE TYPE STRING,
FREE_POSITIONS TYPE STRING,
EVALUATION_PRIORITY TYPE STRING,
LOG_SYSTEM TYPE STRING,
DEEP_DELETE_FLG TYPE STRING,END OF T_EKKO_STR. DATA: WA_BAPI1176_CMP_NODEDATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BAPI1176_CMP_NODEDATA_STR-NODE_ID sy-vline
WA_BAPI1176_CMP_NODEDATA_STR-NODE_NAME sy-vline
WA_BAPI1176_CMP_NODEDATA_STR-CLASS_NUM sy-vline
WA_BAPI1176_CMP_NODEDATA_STR-CLASS_TYPE sy-vline
WA_BAPI1176_CMP_NODEDATA_STR-NODE_TYPE sy-vline
WA_BAPI1176_CMP_NODEDATA_STR-DELETE_FLG sy-vline
WA_BAPI1176_CMP_NODEDATA_STR-SELECT_MANDATORY sy-vline
WA_BAPI1176_CMP_NODEDATA_STR-SELECT_MULTIPLE sy-vline
WA_BAPI1176_CMP_NODEDATA_STR-FREE_POSITIONS sy-vline
WA_BAPI1176_CMP_NODEDATA_STR-EVALUATION_PRIORITY sy-vline
WA_BAPI1176_CMP_NODEDATA_STR-LOG_SYSTEM sy-vline
WA_BAPI1176_CMP_NODEDATA_STR-DEEP_DELETE_FLG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.