ABAP Select data from SAP table BAPI1176_CMP_COLNODETEXT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BAPI1176_CMP_COLNODETEXT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BAPI1176_CMP_COLNODETEXT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BAPI1176_CMP_COLNODETEXT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BAPI1176_CMP_COLNODETEXT TYPE STANDARD TABLE OF BAPI1176_CMP_COLNODETEXT,
      WA_BAPI1176_CMP_COLNODETEXT TYPE BAPI1176_CMP_COLNODETEXT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BAPI1176_CMP_COLNODETEXT> TYPE BAPI1176_CMP_COLNODETEXT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BAPI1176_CMP_COLNODETEXT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BAPI1176_CMP_COLNODETEXT
  INTO TABLE IT_BAPI1176_CMP_COLNODETEXT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BAPI1176_CMP_COLNODETEXT
*  INTO TABLE @DATA(IT_BAPI1176_CMP_COLNODETEXT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BAPI1176_CMP_COLNODETEXT INDEX 1 INTO DATA(WA_BAPI1176_CMP_COLNODETEXT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BAPI1176_CMP_COLNODETEXT ASSIGNING <BAPI1176_CMP_COLNODETEXT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BAPI1176_CMP_COLNODETEXT>-NODE_ID = 1.
<BAPI1176_CMP_COLNODETEXT>-LANGU = 1.
<BAPI1176_CMP_COLNODETEXT>-LANGU_ISO = 1.
<BAPI1176_CMP_COLNODETEXT>-TEXT = 1.
<BAPI1176_CMP_COLNODETEXT>-DELETE_FLG = 1.
ENDLOOP.

LOOP AT IT_BAPI1176_CMP_COLNODETEXT INTO WA_BAPI1176_CMP_COLNODETEXT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline, ENDLOOP.
   
*Add any further fields from structure WA_BAPI1176_CMP_COLNODETEXT you want to display...

  WRITE:/ sy-uline.
* Aternatively use generic code to Write field values (and NAME) to screen report
  DO.
    ASSIGN COMPONENT sy-index OF STRUCTURE wa_BAPI1176_CMP_COLNODETEXT TO <field>.
    IF sy-subrc <> 0. EXIT. ENDIF.
    WRITE:/ 'Field Value', <field>, sy-vline.
    gd_str = <field> .
    lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ).
    lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ).
    WRITE:/ 'Field Name', lv_fieldname.
  ENDDO.

  
*Redo loop but convert all fields from internal to out value  
LOOP AT IT_BAPI1176_CMP_COLNODETEXT INTO WA_BAPI1176_CMP_COLNODETEXT.


*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Convert all fields to display/output versions using conversion routines
  PERFORM convert_all_field_values CHANGING wa_EKKO.
	 
ENDLOOP.

  
*&---------------------------------------------------------------------*
*& Form convert_all_field_values
*&---------------------------------------------------------------------*
FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO.
DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit PNUID, internal->external for field NODE_ID CALL FUNCTION 'CONVERSION_EXIT_PNUID_OUTPUT' EXPORTING input = WA_BAPI1176_CMP_COLNODETEXT-NODE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BAPI1176_CMP_COLNODETEXT-NODE_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_BAPI1176_CMP_COLNODETEXT-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_BAPI1176_CMP_COLNODETEXT-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BAPI1176_CMP_COLNODETEXT_STR,
NODE_ID TYPE STRING,
LANGU TYPE STRING,
LANGU_ISO TYPE STRING,
TEXT TYPE STRING,
DELETE_FLG TYPE STRING,END OF T_EKKO_STR. DATA: WA_BAPI1176_CMP_COLNODETEXT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BAPI1176_CMP_COLNODETEXT_STR-NODE_ID sy-vline
WA_BAPI1176_CMP_COLNODETEXT_STR-LANGU sy-vline
WA_BAPI1176_CMP_COLNODETEXT_STR-LANGU_ISO sy-vline
WA_BAPI1176_CMP_COLNODETEXT_STR-TEXT sy-vline
WA_BAPI1176_CMP_COLNODETEXT_STR-DELETE_FLG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.