ABAP Select data from SAP table BAL_S_FCAT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP BAL_S_FCAT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to BAL_S_FCAT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the BAL_S_FCAT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_BAL_S_FCAT TYPE STANDARD TABLE OF BAL_S_FCAT,
      WA_BAL_S_FCAT TYPE BAL_S_FCAT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <BAL_S_FCAT> TYPE BAL_S_FCAT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_BAL_S_FCAT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM BAL_S_FCAT
  INTO TABLE IT_BAL_S_FCAT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM BAL_S_FCAT
*  INTO TABLE @DATA(IT_BAL_S_FCAT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_BAL_S_FCAT INDEX 1 INTO DATA(WA_BAL_S_FCAT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_BAL_S_FCAT ASSIGNING <BAL_S_FCAT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<BAL_S_FCAT>-REF_TABLE = 1.
<BAL_S_FCAT>-REF_FIELD = 1.
<BAL_S_FCAT>-COL_POS = 1.
<BAL_S_FCAT>-OUTPUTLEN = 1.
<BAL_S_FCAT>-NO_OUT = 1.
ENDLOOP.

LOOP AT IT_BAL_S_FCAT INTO WA_BAL_S_FCAT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_BAL_S_FCAT-HOTSPOT, sy-vline,
WA_BAL_S_FCAT-TECH, sy-vline,
WA_BAL_S_FCAT-COLTEXT, sy-vline,
WA_BAL_S_FCAT-COLDDICTXT, sy-vline,
WA_BAL_S_FCAT-CLTXT_ADD, sy-vline,
WA_BAL_S_FCAT-CLTXT_LEN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_BAL_S_FCAT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_BAL_S_FCAT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_BAL_S_FCAT INTO WA_BAL_S_FCAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_BAL_S_FCAT_STR,
REF_TABLE TYPE STRING,
REF_FIELD TYPE STRING,
COL_POS TYPE STRING,
OUTPUTLEN TYPE STRING,
NO_OUT TYPE STRING,
HOTSPOT TYPE STRING,
TECH TYPE STRING,
COLTEXT TYPE STRING,
COLDDICTXT TYPE STRING,
CLTXT_ADD TYPE STRING,
CLTXT_LEN TYPE STRING,
CLTXT_SEP TYPE STRING,
IS_EXTERN TYPE STRING,
IS_TREECOL TYPE STRING,END OF T_EKKO_STR. DATA: WA_BAL_S_FCAT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_BAL_S_FCAT_STR-REF_TABLE sy-vline
WA_BAL_S_FCAT_STR-REF_FIELD sy-vline
WA_BAL_S_FCAT_STR-COL_POS sy-vline
WA_BAL_S_FCAT_STR-OUTPUTLEN sy-vline
WA_BAL_S_FCAT_STR-NO_OUT sy-vline
WA_BAL_S_FCAT_STR-HOTSPOT sy-vline
WA_BAL_S_FCAT_STR-TECH sy-vline
WA_BAL_S_FCAT_STR-COLTEXT sy-vline
WA_BAL_S_FCAT_STR-COLDDICTXT sy-vline
WA_BAL_S_FCAT_STR-CLTXT_ADD sy-vline
WA_BAL_S_FCAT_STR-CLTXT_LEN sy-vline
WA_BAL_S_FCAT_STR-CLTXT_SEP sy-vline
WA_BAL_S_FCAT_STR-IS_EXTERN sy-vline
WA_BAL_S_FCAT_STR-IS_TREECOL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.