ABAP Select data from SAP table AUT_RCXXB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP AUT_RCXXB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to AUT_RCXXB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the AUT_RCXXB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_AUT_RCXXB TYPE STANDARD TABLE OF AUT_RCXXB,
      WA_AUT_RCXXB TYPE AUT_RCXXB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <AUT_RCXXB> TYPE AUT_RCXXB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_AUT_RCXXB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM AUT_RCXXB
  INTO TABLE IT_AUT_RCXXB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM AUT_RCXXB
*  INTO TABLE @DATA(IT_AUT_RCXXB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_AUT_RCXXB INDEX 1 INTO DATA(WA_AUT_RCXXB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_AUT_RCXXB ASSIGNING <AUT_RCXXB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<AUT_RCXXB>-TABKEY = 1.
<AUT_RCXXB>-MANDT = 1.
<AUT_RCXXB>-SIGN_NO = 1.
<AUT_RCXXB>-SIGN_OBJ = 1.
<AUT_RCXXB>-NUMB_CUR = 1.
ENDLOOP.

LOOP AT IT_AUT_RCXXB INTO WA_AUT_RCXXB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_AUT_RCXXB-NUMB_TOT, sy-vline,
WA_AUT_RCXXB-AENNR, sy-vline,
WA_AUT_RCXXB-AETYP, sy-vline,
WA_AUT_RCXXB-OBJKT, sy-vline,
WA_AUT_RCXXB-PN_NR, sy-vline,
WA_AUT_RCXXB-PRUEFLOS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_AUT_RCXXB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_AUT_RCXXB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_AUT_RCXXB INTO WA_AUT_RCXXB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AUT_RCXXB-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUT_RCXXB-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRUEFLOS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AUT_RCXXB-PRUEFLOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUT_RCXXB-PRUEFLOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ZAEHLER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AUT_RCXXB-ZAEHLER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUT_RCXXB-ZAEHLER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_AUT_RCXXB-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUT_RCXXB-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AUT_RCXXB-DOKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUT_RCXXB-DOKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field COMM_LANG CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_AUT_RCXXB-COMM_LANG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUT_RCXXB-COMM_LANG.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_AUT_RCXXB_STR,
TABKEY TYPE STRING,
MANDT TYPE STRING,
SIGN_NO TYPE STRING,
SIGN_OBJ TYPE STRING,
NUMB_CUR TYPE STRING,
NUMB_TOT TYPE STRING,
AENNR TYPE STRING,
AETYP TYPE STRING,
OBJKT TYPE STRING,
PN_NR TYPE STRING,
PRUEFLOS TYPE STRING,
KZART TYPE STRING,
ZAEHLER TYPE STRING,
VORGLFNR TYPE STRING,
CRID TYPE STRING,
FTNO TYPE STRING,
FVNO TYPE STRING,
TAB_MELD TYPE STRING,
TAB_ZEILE TYPE STRING,
SIGN_COUNT TYPE STRING,
ATWRT TYPE STRING,
MATNR TYPE STRING,
CHARG TYPE STRING,
EBRID TYPE STRING,
WERKS TYPE STRING,
VERSION TYPE STRING,
DOKAR TYPE STRING,
DOKNR TYPE STRING,
DOKVR TYPE STRING,
DOKTL TYPE STRING,
DOKST TYPE STRING,
STZAE TYPE STRING,
SIGNSTRAT TYPE STRING,
COUNT_STEP TYPE STRING,
SIGNSTEP TYPE STRING,
SIGNAUTH TYPE STRING,
FLG_EOSP TYPE STRING,
SIGN_DATE TYPE STRING,
SIGN_TIME TYPE STRING,
SIGNER TYPE STRING,
SIGNER_NAM_FIRST TYPE STRING,
SIGNER_NAM_LAST TYPE STRING,
COMM_LANG TYPE STRING,
SIGDOC_LEN TYPE STRING,
METHOD TYPE STRING,
REASON TYPE STRING,
REASON_KTXT TYPE STRING,
TIMSTAMP TYPE STRING,
TZONE TYPE STRING,
CODEPAGE TYPE STRING,
SAVEMODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_AUT_RCXXB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_AUT_RCXXB_STR-TABKEY sy-vline
WA_AUT_RCXXB_STR-MANDT sy-vline
WA_AUT_RCXXB_STR-SIGN_NO sy-vline
WA_AUT_RCXXB_STR-SIGN_OBJ sy-vline
WA_AUT_RCXXB_STR-NUMB_CUR sy-vline
WA_AUT_RCXXB_STR-NUMB_TOT sy-vline
WA_AUT_RCXXB_STR-AENNR sy-vline
WA_AUT_RCXXB_STR-AETYP sy-vline
WA_AUT_RCXXB_STR-OBJKT sy-vline
WA_AUT_RCXXB_STR-PN_NR sy-vline
WA_AUT_RCXXB_STR-PRUEFLOS sy-vline
WA_AUT_RCXXB_STR-KZART sy-vline
WA_AUT_RCXXB_STR-ZAEHLER sy-vline
WA_AUT_RCXXB_STR-VORGLFNR sy-vline
WA_AUT_RCXXB_STR-CRID sy-vline
WA_AUT_RCXXB_STR-FTNO sy-vline
WA_AUT_RCXXB_STR-FVNO sy-vline
WA_AUT_RCXXB_STR-TAB_MELD sy-vline
WA_AUT_RCXXB_STR-TAB_ZEILE sy-vline
WA_AUT_RCXXB_STR-SIGN_COUNT sy-vline
WA_AUT_RCXXB_STR-ATWRT sy-vline
WA_AUT_RCXXB_STR-MATNR sy-vline
WA_AUT_RCXXB_STR-CHARG sy-vline
WA_AUT_RCXXB_STR-EBRID sy-vline
WA_AUT_RCXXB_STR-WERKS sy-vline
WA_AUT_RCXXB_STR-VERSION sy-vline
WA_AUT_RCXXB_STR-DOKAR sy-vline
WA_AUT_RCXXB_STR-DOKNR sy-vline
WA_AUT_RCXXB_STR-DOKVR sy-vline
WA_AUT_RCXXB_STR-DOKTL sy-vline
WA_AUT_RCXXB_STR-DOKST sy-vline
WA_AUT_RCXXB_STR-STZAE sy-vline
WA_AUT_RCXXB_STR-SIGNSTRAT sy-vline
WA_AUT_RCXXB_STR-COUNT_STEP sy-vline
WA_AUT_RCXXB_STR-SIGNSTEP sy-vline
WA_AUT_RCXXB_STR-SIGNAUTH sy-vline
WA_AUT_RCXXB_STR-FLG_EOSP sy-vline
WA_AUT_RCXXB_STR-SIGN_DATE sy-vline
WA_AUT_RCXXB_STR-SIGN_TIME sy-vline
WA_AUT_RCXXB_STR-SIGNER sy-vline
WA_AUT_RCXXB_STR-SIGNER_NAM_FIRST sy-vline
WA_AUT_RCXXB_STR-SIGNER_NAM_LAST sy-vline
WA_AUT_RCXXB_STR-COMM_LANG sy-vline
WA_AUT_RCXXB_STR-SIGDOC_LEN sy-vline
WA_AUT_RCXXB_STR-METHOD sy-vline
WA_AUT_RCXXB_STR-REASON sy-vline
WA_AUT_RCXXB_STR-REASON_KTXT sy-vline
WA_AUT_RCXXB_STR-TIMSTAMP sy-vline
WA_AUT_RCXXB_STR-TZONE sy-vline
WA_AUT_RCXXB_STR-CODEPAGE sy-vline
WA_AUT_RCXXB_STR-SAVEMODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.