ABAP Select data from SAP table AUSZ1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP AUSZ1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to AUSZ1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the AUSZ1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_AUSZ1 TYPE STANDARD TABLE OF AUSZ1,
      WA_AUSZ1 TYPE AUSZ1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <AUSZ1> TYPE AUSZ1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_AUSZ1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM AUSZ1
  INTO TABLE IT_AUSZ1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM AUSZ1
*  INTO TABLE @DATA(IT_AUSZ12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_AUSZ1 INDEX 1 INTO DATA(WA_AUSZ12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_AUSZ1 ASSIGNING <AUSZ1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<AUSZ1>-BELNR = 1.
<AUSZ1>-BUKRS = 1.
<AUSZ1>-GJAHR = 1.
<AUSZ1>-BUZEI = 1.
<AUSZ1>-SKNTO = 1.
ENDLOOP.

LOOP AT IT_AUSZ1 INTO WA_AUSZ1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_AUSZ1-WSKTO, sy-vline,
WA_AUSZ1-RDIFF, sy-vline,
WA_AUSZ1-SKNT2, sy-vline,
WA_AUSZ1-SKNT3, sy-vline,
WA_AUSZ1-RDIF2, sy-vline,
WA_AUSZ1-RDIF3, sy-vline.
ENDLOOP. *Add any further fields from structure WA_AUSZ1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_AUSZ1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_AUSZ1 INTO WA_AUSZ1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AUSZ1-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_AUSZ1-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field SKNTO CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_AUSZ1-SKNTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-SKNTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field WSKTO CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_AUSZ1-WSKTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-WSKTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field RDIFF CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_AUSZ1-RDIFF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-RDIFF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field SKNT2 CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_AUSZ1-SKNT2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-SKNT2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field SKNT3 CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_AUSZ1-SKNT3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-SKNT3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field RDIF2 CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_AUSZ1-RDIF2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-RDIF2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field RDIF3 CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_AUSZ1-RDIF3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-RDIF3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field QBSHB CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_AUSZ1-QBSHB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-QBSHB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field PENLC1 CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_AUSZ1-PENLC1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-PENLC1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field PENLC2 CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_AUSZ1-PENLC2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-PENLC2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field PENLC3 CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_AUSZ1-PENLC3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-PENLC3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field PENFC CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_AUSZ1-PENFC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AUSZ1-PENFC.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_AUSZ1_STR,
BELNR TYPE STRING,
BUKRS TYPE STRING,
GJAHR TYPE STRING,
BUZEI TYPE STRING,
SKNTO TYPE STRING,
WSKTO TYPE STRING,
RDIFF TYPE STRING,
SKNT2 TYPE STRING,
SKNT3 TYPE STRING,
RDIF2 TYPE STRING,
RDIF3 TYPE STRING,
QBSHB TYPE STRING,
PENLC1 TYPE STRING,
PENLC2 TYPE STRING,
PENLC3 TYPE STRING,
PENFC TYPE STRING,
PENDAYS TYPE STRING,END OF T_EKKO_STR. DATA: WA_AUSZ1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_AUSZ1_STR-BELNR sy-vline
WA_AUSZ1_STR-BUKRS sy-vline
WA_AUSZ1_STR-GJAHR sy-vline
WA_AUSZ1_STR-BUZEI sy-vline
WA_AUSZ1_STR-SKNTO sy-vline
WA_AUSZ1_STR-WSKTO sy-vline
WA_AUSZ1_STR-RDIFF sy-vline
WA_AUSZ1_STR-SKNT2 sy-vline
WA_AUSZ1_STR-SKNT3 sy-vline
WA_AUSZ1_STR-RDIF2 sy-vline
WA_AUSZ1_STR-RDIF3 sy-vline
WA_AUSZ1_STR-QBSHB sy-vline
WA_AUSZ1_STR-PENLC1 sy-vline
WA_AUSZ1_STR-PENLC2 sy-vline
WA_AUSZ1_STR-PENLC3 sy-vline
WA_AUSZ1_STR-PENFC sy-vline
WA_AUSZ1_STR-PENDAYS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.