ABAP Select data from SAP table ATPSOTCRITCNDN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ATPSOTCRITCNDN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ATPSOTCRITCNDN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ATPSOTCRITCNDN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ATPSOTCRITCNDN TYPE STANDARD TABLE OF ATPSOTCRITCNDN,
      WA_ATPSOTCRITCNDN TYPE ATPSOTCRITCNDN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ATPSOTCRITCNDN> TYPE ATPSOTCRITCNDN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ATPSOTCRITCNDN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ATPSOTCRITCNDN
  INTO TABLE IT_ATPSOTCRITCNDN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ATPSOTCRITCNDN
*  INTO TABLE @DATA(IT_ATPSOTCRITCNDN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ATPSOTCRITCNDN INDEX 1 INTO DATA(WA_ATPSOTCRITCNDN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ATPSOTCRITCNDN ASSIGNING <ATPSOTCRITCNDN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ATPSOTCRITCNDN>-MANDT = 1.
<ATPSOTCRITCNDN>-ATPSELOPTNTOOLCRITRNCNDNUUID = 1.
<ATPSOTCRITCNDN>-ATPSELOPTNTOOLCRITRNUUID = 1.
<ATPSOTCRITCNDN>-ATPSELOPTNTOOLDEFUUID = 1.
<ATPSOTCRITCNDN>-ATPSELOPTNTOOLCNDNORDINALNMBR = 1.
ENDLOOP.

LOOP AT IT_ATPSOTCRITCNDN INTO WA_ATPSOTCRITCNDN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ATPSOTCRITCNDN-ATPSELOPTNTOOLCNDNFLDPATHUUID, sy-vline,
WA_ATPSOTCRITCNDN-ATPSELOPTNTOOLCNDNFLDPATHINTID, sy-vline,
WA_ATPSOTCRITCNDN-ATPSELOPTNTOOLCNDNFLDVALRPRSTN, sy-vline,
WA_ATPSOTCRITCNDN-ATPSELOPTNTOOLCNDNCOMPRNOPTR, sy-vline,
WA_ATPSOTCRITCNDN-ATPSELOPTNTOOLCNDNISEXCLUSIVE, sy-vline,
WA_ATPSOTCRITCNDN-ATPSELOPTNTOOLCNDNRGFRVALUE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ATPSOTCRITCNDN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ATPSOTCRITCNDN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ATPSOTCRITCNDN INTO WA_ATPSOTCRITCNDN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field ATPSELOPTNTOOLCNDNRGFRVALUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ATPSOTCRITCNDN-ATPSELOPTNTOOLCNDNRGFRVALUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ATPSOTCRITCNDN-ATPSELOPTNTOOLCNDNRGFRVALUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ATPSELOPTNTOOLCNDNRGTOVALUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ATPSOTCRITCNDN-ATPSELOPTNTOOLCNDNRGTOVALUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ATPSOTCRITCNDN-ATPSELOPTNTOOLCNDNRGTOVALUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ATPSOTCRITCNDN_STR,
MANDT TYPE STRING,
ATPSELOPTNTOOLCRITRNCNDNUUID TYPE STRING,
ATPSELOPTNTOOLCRITRNUUID TYPE STRING,
ATPSELOPTNTOOLDEFUUID TYPE STRING,
ATPSELOPTNTOOLCNDNORDINALNMBR TYPE STRING,
ATPSELOPTNTOOLCNDNFLDPATHUUID TYPE STRING,
ATPSELOPTNTOOLCNDNFLDPATHINTID TYPE STRING,
ATPSELOPTNTOOLCNDNFLDVALRPRSTN TYPE STRING,
ATPSELOPTNTOOLCNDNCOMPRNOPTR TYPE STRING,
ATPSELOPTNTOOLCNDNISEXCLUSIVE TYPE STRING,
ATPSELOPTNTOOLCNDNRGFRVALUE TYPE STRING,
ATPSELOPTNTOOLCNDNRGFRINTVALUE TYPE STRING,
ATPSELOPTNTOOLCNDNRGFRVALUNIT TYPE STRING,
ATPSELOPTNTOOLCNDNRGTOVALUE TYPE STRING,
ATPSELOPTNTOOLCNDNRGTOINTVALUE TYPE STRING,
ATPSELOPTNTOOLCNDNRGTOVALUNIT TYPE STRING,
BUSPRPSOFREFDVALUEISCOMPLETED TYPE STRING,END OF T_EKKO_STR. DATA: WA_ATPSOTCRITCNDN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ATPSOTCRITCNDN_STR-MANDT sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCRITRNCNDNUUID sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCRITRNUUID sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLDEFUUID sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCNDNORDINALNMBR sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCNDNFLDPATHUUID sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCNDNFLDPATHINTID sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCNDNFLDVALRPRSTN sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCNDNCOMPRNOPTR sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCNDNISEXCLUSIVE sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCNDNRGFRVALUE sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCNDNRGFRINTVALUE sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCNDNRGFRVALUNIT sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCNDNRGTOVALUE sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCNDNRGTOINTVALUE sy-vline
WA_ATPSOTCRITCNDN_STR-ATPSELOPTNTOOLCNDNRGTOVALUNIT sy-vline
WA_ATPSOTCRITCNDN_STR-BUSPRPSOFREFDVALUEISCOMPLETED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.