ABAP Select data from SAP table ATPC_TQA_D into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ATPC_TQA_D table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ATPC_TQA_D. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ATPC_TQA_D table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ATPC_TQA_D TYPE STANDARD TABLE OF ATPC_TQA_D,
      WA_ATPC_TQA_D TYPE ATPC_TQA_D,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ATPC_TQA_D> TYPE ATPC_TQA_D.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ATPC_TQA_D.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ATPC_TQA_D
  INTO TABLE IT_ATPC_TQA_D.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ATPC_TQA_D
*  INTO TABLE @DATA(IT_ATPC_TQA_D2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ATPC_TQA_D INDEX 1 INTO DATA(WA_ATPC_TQA_D2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ATPC_TQA_D ASSIGNING <ATPC_TQA_D>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ATPC_TQA_D>-MANDT = 1.
<ATPC_TQA_D>-CID = 1.
<ATPC_TQA_D>-DELNR = 1.
<ATPC_TQA_D>-DELPS = 1.
<ATPC_TQA_D>-POS = 1.
ENDLOOP.

LOOP AT IT_ATPC_TQA_D INTO WA_ATPC_TQA_D.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ATPC_TQA_D-MATNR, sy-vline,
WA_ATPC_TQA_D-WERKS, sy-vline,
WA_ATPC_TQA_D-LGORT, sy-vline,
WA_ATPC_TQA_D-CHARG, sy-vline,
WA_ATPC_TQA_D-SGT_CATV, sy-vline,
WA_ATPC_TQA_D-SOBKZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ATPC_TQA_D you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ATPC_TQA_D TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ATPC_TQA_D INTO WA_ATPC_TQA_D. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ATPC_TQA_D-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ATPC_TQA_D-MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ATPC_TQA_D_STR,
MANDT TYPE STRING,
CID TYPE STRING,
DELNR TYPE STRING,
DELPS TYPE STRING,
POS TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
CHARG TYPE STRING,
SGT_CATV TYPE STRING,
SOBKZ TYPE STRING,
SSKEY TYPE STRING,
SSKEY_EXT TYPE STRING,
ATPCAT TYPE STRING,
ATPCAT_SUCCESSOR TYPE STRING,
DELNR_SUCCESSOR TYPE STRING,
DELPS_SUCCESSOR TYPE STRING,
ATPDATE TYPE STRING,
REQQTY TYPE STRING,
CNFQTY TYPE STRING,
VALTMS TYPE STRING,
UNAME TYPE STRING,
CREATION_DATE TYPE STRING,
CREATION_TIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_ATPC_TQA_D_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ATPC_TQA_D_STR-MANDT sy-vline
WA_ATPC_TQA_D_STR-CID sy-vline
WA_ATPC_TQA_D_STR-DELNR sy-vline
WA_ATPC_TQA_D_STR-DELPS sy-vline
WA_ATPC_TQA_D_STR-POS sy-vline
WA_ATPC_TQA_D_STR-MATNR sy-vline
WA_ATPC_TQA_D_STR-WERKS sy-vline
WA_ATPC_TQA_D_STR-LGORT sy-vline
WA_ATPC_TQA_D_STR-CHARG sy-vline
WA_ATPC_TQA_D_STR-SGT_CATV sy-vline
WA_ATPC_TQA_D_STR-SOBKZ sy-vline
WA_ATPC_TQA_D_STR-SSKEY sy-vline
WA_ATPC_TQA_D_STR-SSKEY_EXT sy-vline
WA_ATPC_TQA_D_STR-ATPCAT sy-vline
WA_ATPC_TQA_D_STR-ATPCAT_SUCCESSOR sy-vline
WA_ATPC_TQA_D_STR-DELNR_SUCCESSOR sy-vline
WA_ATPC_TQA_D_STR-DELPS_SUCCESSOR sy-vline
WA_ATPC_TQA_D_STR-ATPDATE sy-vline
WA_ATPC_TQA_D_STR-REQQTY sy-vline
WA_ATPC_TQA_D_STR-CNFQTY sy-vline
WA_ATPC_TQA_D_STR-VALTMS sy-vline
WA_ATPC_TQA_D_STR-UNAME sy-vline
WA_ATPC_TQA_D_STR-CREATION_DATE sy-vline
WA_ATPC_TQA_D_STR-CREATION_TIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.