ABAP Select data from SAP table ATP_EKUB_EKES into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ATP_EKUB_EKES table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ATP_EKUB_EKES. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ATP_EKUB_EKES table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ATP_EKUB_EKES TYPE STANDARD TABLE OF ATP_EKUB_EKES,
      WA_ATP_EKUB_EKES TYPE ATP_EKUB_EKES,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ATP_EKUB_EKES> TYPE ATP_EKUB_EKES.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ATP_EKUB_EKES.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ATP_EKUB_EKES
  INTO TABLE IT_ATP_EKUB_EKES.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ATP_EKUB_EKES
*  INTO TABLE @DATA(IT_ATP_EKUB_EKES2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ATP_EKUB_EKES INDEX 1 INTO DATA(WA_ATP_EKUB_EKES2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ATP_EKUB_EKES ASSIGNING <ATP_EKUB_EKES>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ATP_EKUB_EKES>-MANDT = 1.
<ATP_EKUB_EKES>-MATNR = 1.
<ATP_EKUB_EKES>-RESWK = 1.
<ATP_EKUB_EKES>-EBELN = 1.
<ATP_EKUB_EKES>-EBELP = 1.
ENDLOOP.

LOOP AT IT_ATP_EKUB_EKES INTO WA_ATP_EKUB_EKES.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ATP_EKUB_EKES-LOEKZ, sy-vline,
WA_ATP_EKUB_EKES-STATU, sy-vline,
WA_ATP_EKUB_EKES-MEINS, sy-vline,
WA_ATP_EKUB_EKES-UMREZ, sy-vline,
WA_ATP_EKUB_EKES-UMREN, sy-vline,
WA_ATP_EKUB_EKES-WEBAZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ATP_EKUB_EKES you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ATP_EKUB_EKES TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ATP_EKUB_EKES INTO WA_ATP_EKUB_EKES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ATP_EKUB_EKES-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ATP_EKUB_EKES-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ATP_EKUB_EKES-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ATP_EKUB_EKES-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ATP_EKUB_EKES-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ATP_EKUB_EKES-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EMLIF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ATP_EKUB_EKES-EMLIF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ATP_EKUB_EKES-EMLIF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field DISUB_PSPNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_ATP_EKUB_EKES-DISUB_PSPNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ATP_EKUB_EKES-DISUB_PSPNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DISUB_KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ATP_EKUB_EKES-DISUB_KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ATP_EKUB_EKES-DISUB_KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DISUB_VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ATP_EKUB_EKES-DISUB_VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ATP_EKUB_EKES-DISUB_VBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DISUB_OWNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ATP_EKUB_EKES-DISUB_OWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ATP_EKUB_EKES-DISUB_OWNER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ATP_EKUB_EKES_STR,
MANDT TYPE STRING,
MATNR TYPE STRING,
RESWK TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
LOEKZ TYPE STRING,
STATU TYPE STRING,
MEINS TYPE STRING,
UMREZ TYPE STRING,
UMREN TYPE STRING,
WEBAZ TYPE STRING,
BWTAR TYPE STRING,
ELIKZ TYPE STRING,
PSTYP TYPE STRING,
KNTTP TYPE STRING,
BSTYP TYPE STRING,
SOBKZ TYPE STRING,
ARSNR TYPE STRING,
EMLIF TYPE STRING,
LBLKZ TYPE STRING,
RESLO TYPE STRING,
FLS_RSTO TYPE STRING,
ETENS TYPE STRING,
EINDT TYPE STRING,
MENGE TYPE STRING,
DABMG TYPE STRING,
ESTKZ TYPE STRING,
KZDIS TYPE STRING,
CHARG TYPE STRING,
SGT_SCAT TYPE STRING,
SGT_RCAT TYPE STRING,
DISUB_SOBKZ TYPE STRING,
DISUB_PSPNR TYPE STRING,
DISUB_KUNNR TYPE STRING,
DISUB_VBELN TYPE STRING,
DISUB_POSNR TYPE STRING,
DISUB_OWNER TYPE STRING,END OF T_EKKO_STR. DATA: WA_ATP_EKUB_EKES_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ATP_EKUB_EKES_STR-MANDT sy-vline
WA_ATP_EKUB_EKES_STR-MATNR sy-vline
WA_ATP_EKUB_EKES_STR-RESWK sy-vline
WA_ATP_EKUB_EKES_STR-EBELN sy-vline
WA_ATP_EKUB_EKES_STR-EBELP sy-vline
WA_ATP_EKUB_EKES_STR-LOEKZ sy-vline
WA_ATP_EKUB_EKES_STR-STATU sy-vline
WA_ATP_EKUB_EKES_STR-MEINS sy-vline
WA_ATP_EKUB_EKES_STR-UMREZ sy-vline
WA_ATP_EKUB_EKES_STR-UMREN sy-vline
WA_ATP_EKUB_EKES_STR-WEBAZ sy-vline
WA_ATP_EKUB_EKES_STR-BWTAR sy-vline
WA_ATP_EKUB_EKES_STR-ELIKZ sy-vline
WA_ATP_EKUB_EKES_STR-PSTYP sy-vline
WA_ATP_EKUB_EKES_STR-KNTTP sy-vline
WA_ATP_EKUB_EKES_STR-BSTYP sy-vline
WA_ATP_EKUB_EKES_STR-SOBKZ sy-vline
WA_ATP_EKUB_EKES_STR-ARSNR sy-vline
WA_ATP_EKUB_EKES_STR-EMLIF sy-vline
WA_ATP_EKUB_EKES_STR-LBLKZ sy-vline
WA_ATP_EKUB_EKES_STR-RESLO sy-vline
WA_ATP_EKUB_EKES_STR-FLS_RSTO sy-vline
WA_ATP_EKUB_EKES_STR-ETENS sy-vline
WA_ATP_EKUB_EKES_STR-EINDT sy-vline
WA_ATP_EKUB_EKES_STR-MENGE sy-vline
WA_ATP_EKUB_EKES_STR-DABMG sy-vline
WA_ATP_EKUB_EKES_STR-ESTKZ sy-vline
WA_ATP_EKUB_EKES_STR-KZDIS sy-vline
WA_ATP_EKUB_EKES_STR-CHARG sy-vline
WA_ATP_EKUB_EKES_STR-SGT_SCAT sy-vline
WA_ATP_EKUB_EKES_STR-SGT_RCAT sy-vline
WA_ATP_EKUB_EKES_STR-DISUB_SOBKZ sy-vline
WA_ATP_EKUB_EKES_STR-DISUB_PSPNR sy-vline
WA_ATP_EKUB_EKES_STR-DISUB_KUNNR sy-vline
WA_ATP_EKUB_EKES_STR-DISUB_VBELN sy-vline
WA_ATP_EKUB_EKES_STR-DISUB_POSNR sy-vline
WA_ATP_EKUB_EKES_STR-DISUB_OWNER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.