Below is a number of ABAP code snippets to demonstrate how to select data from SAP ARRANG_NAUMF_M__01_F table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ARRANG_NAUMF_M__01_F. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ARRANG_NAUMF_M__01_F table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ARRANG_NAUMF_M__01_F TYPE STANDARD TABLE OF ARRANG_NAUMF_M__01_F,
      WA_ARRANG_NAUMF_M__01_F TYPE ARRANG_NAUMF_M__01_F,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ARRANG_NAUMF_M__01_F> TYPE ARRANG_NAUMF_M__01_F.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ARRANG_NAUMF_M__01_F.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ARRANG_NAUMF_M__01_F
  INTO TABLE IT_ARRANG_NAUMF_M__01_F.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ARRANG_NAUMF_M__01_F
*  INTO TABLE @DATA(IT_ARRANG_NAUMF_M__01_F2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ARRANG_NAUMF_M__01_F INDEX 1 INTO DATA(WA_ARRANG_NAUMF_M__01_F2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ARRANG_NAUMF_M__01_F ASSIGNING <ARRANG_NAUMF_M__01_F>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ARRANG_NAUMF_M__01_F>-KNUMH = 1.
<ARRANG_NAUMF_M__01_F>-KOPOS = 1.
<ARRANG_NAUMF_M__01_F>-BLTYPN = 1.
<ARRANG_NAUMF_M__01_F>-EBELN = 1.
<ARRANG_NAUMF_M__01_F>-EBELP = 1.
ENDLOOP.

LOOP AT IT_ARRANG_NAUMF_M__01_F INTO WA_ARRANG_NAUMF_M__01_F.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ARRANG_NAUMF_M__01_F-BLTYPF, sy-vline,
WA_ARRANG_NAUMF_M__01_F-BELNR, sy-vline,
WA_ARRANG_NAUMF_M__01_F-GJAHR, sy-vline,
WA_ARRANG_NAUMF_M__01_F-BUZEI, sy-vline,
WA_ARRANG_NAUMF_M__01_F-ETENR, sy-vline,
WA_ARRANG_NAUMF_M__01_F-WKOPAR_LI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ARRANG_NAUMF_M__01_F you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ARRANG_NAUMF_M__01_F TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ARRANG_NAUMF_M__01_F INTO WA_ARRANG_NAUMF_M__01_F. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ARRANG_NAUMF_M__01_F-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARRANG_NAUMF_M__01_F-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ARRANG_NAUMF_M__01_F-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARRANG_NAUMF_M__01_F-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_ARRANG_NAUMF_M__01_F-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARRANG_NAUMF_M__01_F-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ARRANG_NAUMF_M__01_F-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARRANG_NAUMF_M__01_F-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PERI, internal->external for field SPMON CALL FUNCTION 'CONVERSION_EXIT_PERI_OUTPUT' EXPORTING input = WA_ARRANG_NAUMF_M__01_F-SPMON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARRANG_NAUMF_M__01_F-SPMON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BOMAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ARRANG_NAUMF_M__01_F-BOMAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARRANG_NAUMF_M__01_F-BOMAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BOLIF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ARRANG_NAUMF_M__01_F-BOLIF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARRANG_NAUMF_M__01_F-BOLIF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BONEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ARRANG_NAUMF_M__01_F-BONEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARRANG_NAUMF_M__01_F-BONEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_ARRANG_NAUMF_M__01_F-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARRANG_NAUMF_M__01_F-MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ARRANG_NAUMF_M__01_F_STR,
KNUMH TYPE STRING,
KOPOS TYPE STRING,
BLTYPN TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
BLTYPF TYPE STRING,
BELNR TYPE STRING,
GJAHR TYPE STRING,
BUZEI TYPE STRING,
ETENR TYPE STRING,
WKOPAR_LI TYPE STRING,
LIFNR TYPE STRING,
WERKS TYPE STRING,
MWSKZ TYPE STRING,
SPMON TYPE STRING,
BOMAT TYPE STRING,
LANDL TYPE STRING,
EKORG TYPE STRING,
EKGRP TYPE STRING,
VKORG TYPE STRING,
VTWEG TYPE STRING,
SPART TYPE STRING,
BUKRS TYPE STRING,
BOLIF TYPE STRING,
BONEM TYPE STRING,
MATNR TYPE STRING,
MATKL TYPE STRING,
LTSNR TYPE STRING,
BSTYP TYPE STRING,
BSART TYPE STRING,
LFTYP TYPE STRING,
LFART TYPE STRING,
WRART TYPE STRING,
WBTYP TYPE STRING,
DOCTYPE TYPE STRING,
KSPAEB TYPE STRING,END OF T_EKKO_STR. DATA: WA_ARRANG_NAUMF_M__01_F_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-KNUMH sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-KOPOS sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-BLTYPN sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-EBELN sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-EBELP sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-BLTYPF sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-BELNR sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-GJAHR sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-BUZEI sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-ETENR sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-WKOPAR_LI sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-LIFNR sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-WERKS sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-MWSKZ sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-SPMON sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-BOMAT sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-LANDL sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-EKORG sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-EKGRP sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-VKORG sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-VTWEG sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-SPART sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-BUKRS sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-BOLIF sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-BONEM sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-MATNR sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-MATKL sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-LTSNR sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-BSTYP sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-BSART sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-LFTYP sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-LFART sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-WRART sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-WBTYP sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-DOCTYPE sy-vline
WA_ARRANG_NAUMF_M__01_F_STR-KSPAEB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.