ABAP Select data from SAP table ARBPL_ARC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ARBPL_ARC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ARBPL_ARC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ARBPL_ARC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ARBPL_ARC TYPE STANDARD TABLE OF ARBPL_ARC,
      WA_ARBPL_ARC TYPE ARBPL_ARC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ARBPL_ARC> TYPE ARBPL_ARC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ARBPL_ARC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ARBPL_ARC
  INTO TABLE IT_ARBPL_ARC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ARBPL_ARC
*  INTO TABLE @DATA(IT_ARBPL_ARC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ARBPL_ARC INDEX 1 INTO DATA(WA_ARBPL_ARC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ARBPL_ARC ASSIGNING <ARBPL_ARC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ARBPL_ARC>-ARBID = 1.
<ARBPL_ARC>-ARBPL = 1.
<ARBPL_ARC>-CPLGR = 1.
<ARBPL_ARC>-DATUB = 1.
<ARBPL_ARC>-DATUV = 1.
ENDLOOP.

LOOP AT IT_ARBPL_ARC INTO WA_ARBPL_ARC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ARBPL_ARC-KAPID, sy-vline,
WA_ARBPL_ARC-KOKRS, sy-vline,
WA_ARBPL_ARC-KOSTL, sy-vline,
WA_ARBPL_ARC-KTEXT, sy-vline,
WA_ARBPL_ARC-KTSCH, sy-vline,
WA_ARBPL_ARC-KTSCH_REF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ARBPL_ARC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ARBPL_ARC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ARBPL_ARC INTO WA_ARBPL_ARC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ARBPL_ARC-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPDEV, internal->external for field PDEST CALL FUNCTION 'CONVERSION_EXIT_SPDEV_OUTPUT' EXPORTING input = WA_ARBPL_ARC-PDEST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-PDEST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGARB CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-VGARB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-VGARB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGDAU CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-VGDAU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-VGDAU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE01 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-VGE01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-VGE01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE02 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-VGE02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-VGE02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE03 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-VGE03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-VGE03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE04 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-VGE04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-VGE04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE05 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-VGE05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-VGE05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field VGE06 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-VGE06 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-VGE06.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIWM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-ZEIWM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-ZEIWM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIWN CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-ZEIWN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-ZEIWN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ARBPL_ARC-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRZ01 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ARBPL_ARC-PRZ01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-PRZ01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LEINH1 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-LEINH1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-LEINH1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LEINH2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-LEINH2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-LEINH2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LEINH3 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-LEINH3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-LEINH3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LEINH4 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-LEINH4 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-LEINH4.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LEINH5 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-LEINH5 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-LEINH5.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LEINH6 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ARBPL_ARC-LEINH6 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBPL_ARC-LEINH6.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ARBPL_ARC_STR,
ARBID TYPE STRING,
ARBPL TYPE STRING,
CPLGR TYPE STRING,
DATUB TYPE STRING,
DATUV TYPE STRING,
KAPID TYPE STRING,
KOKRS TYPE STRING,
KOSTL TYPE STRING,
KTEXT TYPE STRING,
KTSCH TYPE STRING,
KTSCH_REF TYPE STRING,
LAR01 TYPE STRING,
LAR01_REF TYPE STRING,
LAR02 TYPE STRING,
LAR02_REF TYPE STRING,
LAR03 TYPE STRING,
LAR03_REF TYPE STRING,
LAR04 TYPE STRING,
LAR04_REF TYPE STRING,
LAR05 TYPE STRING,
LAR05_REF TYPE STRING,
LAR06 TYPE STRING,
LAR06_REF TYPE STRING,
LARN1 TYPE STRING,
LARN1_REF TYPE STRING,
LOANZ TYPE STRING,
LOANZ_REF TYPE STRING,
LOART TYPE STRING,
LOART_REF TYPE STRING,
LVORM TYPE STRING,
LOGRP TYPE STRING,
LOGRP_REF TYPE STRING,
MANDT TYPE STRING,
MATYP TYPE STRING,
MOLGA TYPE STRING,
ORTGR TYPE STRING,
PAR01 TYPE STRING,
PAR02 TYPE STRING,
PAR03 TYPE STRING,
PAR04 TYPE STRING,
PAR05 TYPE STRING,
PAR06 TYPE STRING,
PDEST TYPE STRING,
PLANV TYPE STRING,
QUALF TYPE STRING,
QUALF_REF TYPE STRING,
RASCH TYPE STRING,
RASCH_REF TYPE STRING,
RSANZ TYPE STRING,
RSANZ_REF TYPE STRING,
RUZUS TYPE STRING,
SORTB TYPE STRING,
STATUS TYPE STRING,
STEUS TYPE STRING,
STEUS_REF TYPE STRING,
VGARB TYPE STRING,
VGDAU TYPE STRING,
VGDIM TYPE STRING,
VGD01 TYPE STRING,
VGD02 TYPE STRING,
VGD03 TYPE STRING,
VGD04 TYPE STRING,
VGD05 TYPE STRING,
VGD06 TYPE STRING,
VGE01 TYPE STRING,
VGE02 TYPE STRING,
VGE03 TYPE STRING,
VGE04 TYPE STRING,
VGE05 TYPE STRING,
VGE06 TYPE STRING,
VGM01 TYPE STRING,
VGM02 TYPE STRING,
VGM03 TYPE STRING,
VGM04 TYPE STRING,
VGM05 TYPE STRING,
VGM06 TYPE STRING,
VGT01 TYPE STRING,
VGT02 TYPE STRING,
VGT03 TYPE STRING,
VGT04 TYPE STRING,
VGT05 TYPE STRING,
VGT06 TYPE STRING,
VGTL1 TYPE STRING,
VGTL2 TYPE STRING,
VGTL3 TYPE STRING,
VGTL4 TYPE STRING,
VGTL5 TYPE STRING,
VGTL6 TYPE STRING,
VGWTS TYPE STRING,
WERKS TYPE STRING,
XSPRR TYPE STRING,
XTERM TYPE STRING,
ZGR01 TYPE STRING,
ZGR01_REF TYPE STRING,
ZGR02 TYPE STRING,
ZGR02_REF TYPE STRING,
ZGR03 TYPE STRING,
ZGR03_REF TYPE STRING,
ZGR04 TYPE STRING,
ZGR04_REF TYPE STRING,
ZGR05 TYPE STRING,
ZGR05_REF TYPE STRING,
ZGR06 TYPE STRING,
ZGR06_REF TYPE STRING,
ZEIWM TYPE STRING,
ZEIWN TYPE STRING,
ZWMIN TYPE STRING,
ZWNOR TYPE STRING,
HR TYPE STRING,
PRVBE TYPE STRING,
SUBSYS TYPE STRING,
BDEGR TYPE STRING,
RGEKZ TYPE STRING,
SLWID TYPE STRING,
LIFNR TYPE STRING,
SLWID_REF TYPE STRING,
LIFNR_REF TYPE STRING,
FLG_AFR TYPE STRING,
ISTBED_KZ TYPE STRING,
PRZ01 TYPE STRING,
PRZ01_REF TYPE STRING,
ACTXY1 TYPE STRING,
ACTXK1 TYPE STRING,
LEINH1 TYPE STRING,
BDE1 TYPE STRING,
SAKL1 TYPE STRING,
ACTXY2 TYPE STRING,
ACTXK2 TYPE STRING,
LEINH2 TYPE STRING,
BDE2 TYPE STRING,
SAKL2 TYPE STRING,
ACTXY3 TYPE STRING,
ACTXK3 TYPE STRING,
LEINH3 TYPE STRING,
BDE3 TYPE STRING,
SAKL3 TYPE STRING,
ACTXY4 TYPE STRING,
ACTXK4 TYPE STRING,
LEINH4 TYPE STRING,
BDE4 TYPE STRING,
SAKL4 TYPE STRING,
ACTXY5 TYPE STRING,
ACTXK5 TYPE STRING,
LEINH5 TYPE STRING,
BDE5 TYPE STRING,
SAKL5 TYPE STRING,
ACTXY6 TYPE STRING,
ACTXK6 TYPE STRING,
LEINH6 TYPE STRING,
BDE6 TYPE STRING,
SAKL6 TYPE STRING,
BDEP TYPE STRING,
SAKLP TYPE STRING,
CLASSNAME TYPE STRING,
CLASS_DES TYPE STRING,
CLASSCAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_ARBPL_ARC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ARBPL_ARC_STR-ARBID sy-vline
WA_ARBPL_ARC_STR-ARBPL sy-vline
WA_ARBPL_ARC_STR-CPLGR sy-vline
WA_ARBPL_ARC_STR-DATUB sy-vline
WA_ARBPL_ARC_STR-DATUV sy-vline
WA_ARBPL_ARC_STR-KAPID sy-vline
WA_ARBPL_ARC_STR-KOKRS sy-vline
WA_ARBPL_ARC_STR-KOSTL sy-vline
WA_ARBPL_ARC_STR-KTEXT sy-vline
WA_ARBPL_ARC_STR-KTSCH sy-vline
WA_ARBPL_ARC_STR-KTSCH_REF sy-vline
WA_ARBPL_ARC_STR-LAR01 sy-vline
WA_ARBPL_ARC_STR-LAR01_REF sy-vline
WA_ARBPL_ARC_STR-LAR02 sy-vline
WA_ARBPL_ARC_STR-LAR02_REF sy-vline
WA_ARBPL_ARC_STR-LAR03 sy-vline
WA_ARBPL_ARC_STR-LAR03_REF sy-vline
WA_ARBPL_ARC_STR-LAR04 sy-vline
WA_ARBPL_ARC_STR-LAR04_REF sy-vline
WA_ARBPL_ARC_STR-LAR05 sy-vline
WA_ARBPL_ARC_STR-LAR05_REF sy-vline
WA_ARBPL_ARC_STR-LAR06 sy-vline
WA_ARBPL_ARC_STR-LAR06_REF sy-vline
WA_ARBPL_ARC_STR-LARN1 sy-vline
WA_ARBPL_ARC_STR-LARN1_REF sy-vline
WA_ARBPL_ARC_STR-LOANZ sy-vline
WA_ARBPL_ARC_STR-LOANZ_REF sy-vline
WA_ARBPL_ARC_STR-LOART sy-vline
WA_ARBPL_ARC_STR-LOART_REF sy-vline
WA_ARBPL_ARC_STR-LVORM sy-vline
WA_ARBPL_ARC_STR-LOGRP sy-vline
WA_ARBPL_ARC_STR-LOGRP_REF sy-vline
WA_ARBPL_ARC_STR-MANDT sy-vline
WA_ARBPL_ARC_STR-MATYP sy-vline
WA_ARBPL_ARC_STR-MOLGA sy-vline
WA_ARBPL_ARC_STR-ORTGR sy-vline
WA_ARBPL_ARC_STR-PAR01 sy-vline
WA_ARBPL_ARC_STR-PAR02 sy-vline
WA_ARBPL_ARC_STR-PAR03 sy-vline
WA_ARBPL_ARC_STR-PAR04 sy-vline
WA_ARBPL_ARC_STR-PAR05 sy-vline
WA_ARBPL_ARC_STR-PAR06 sy-vline
WA_ARBPL_ARC_STR-PDEST sy-vline
WA_ARBPL_ARC_STR-PLANV sy-vline
WA_ARBPL_ARC_STR-QUALF sy-vline
WA_ARBPL_ARC_STR-QUALF_REF sy-vline
WA_ARBPL_ARC_STR-RASCH sy-vline
WA_ARBPL_ARC_STR-RASCH_REF sy-vline
WA_ARBPL_ARC_STR-RSANZ sy-vline
WA_ARBPL_ARC_STR-RSANZ_REF sy-vline
WA_ARBPL_ARC_STR-RUZUS sy-vline
WA_ARBPL_ARC_STR-SORTB sy-vline
WA_ARBPL_ARC_STR-STATUS sy-vline
WA_ARBPL_ARC_STR-STEUS sy-vline
WA_ARBPL_ARC_STR-STEUS_REF sy-vline
WA_ARBPL_ARC_STR-VGARB sy-vline
WA_ARBPL_ARC_STR-VGDAU sy-vline
WA_ARBPL_ARC_STR-VGDIM sy-vline
WA_ARBPL_ARC_STR-VGD01 sy-vline
WA_ARBPL_ARC_STR-VGD02 sy-vline
WA_ARBPL_ARC_STR-VGD03 sy-vline
WA_ARBPL_ARC_STR-VGD04 sy-vline
WA_ARBPL_ARC_STR-VGD05 sy-vline
WA_ARBPL_ARC_STR-VGD06 sy-vline
WA_ARBPL_ARC_STR-VGE01 sy-vline
WA_ARBPL_ARC_STR-VGE02 sy-vline
WA_ARBPL_ARC_STR-VGE03 sy-vline
WA_ARBPL_ARC_STR-VGE04 sy-vline
WA_ARBPL_ARC_STR-VGE05 sy-vline
WA_ARBPL_ARC_STR-VGE06 sy-vline
WA_ARBPL_ARC_STR-VGM01 sy-vline
WA_ARBPL_ARC_STR-VGM02 sy-vline
WA_ARBPL_ARC_STR-VGM03 sy-vline
WA_ARBPL_ARC_STR-VGM04 sy-vline
WA_ARBPL_ARC_STR-VGM05 sy-vline
WA_ARBPL_ARC_STR-VGM06 sy-vline
WA_ARBPL_ARC_STR-VGT01 sy-vline
WA_ARBPL_ARC_STR-VGT02 sy-vline
WA_ARBPL_ARC_STR-VGT03 sy-vline
WA_ARBPL_ARC_STR-VGT04 sy-vline
WA_ARBPL_ARC_STR-VGT05 sy-vline
WA_ARBPL_ARC_STR-VGT06 sy-vline
WA_ARBPL_ARC_STR-VGTL1 sy-vline
WA_ARBPL_ARC_STR-VGTL2 sy-vline
WA_ARBPL_ARC_STR-VGTL3 sy-vline
WA_ARBPL_ARC_STR-VGTL4 sy-vline
WA_ARBPL_ARC_STR-VGTL5 sy-vline
WA_ARBPL_ARC_STR-VGTL6 sy-vline
WA_ARBPL_ARC_STR-VGWTS sy-vline
WA_ARBPL_ARC_STR-WERKS sy-vline
WA_ARBPL_ARC_STR-XSPRR sy-vline
WA_ARBPL_ARC_STR-XTERM sy-vline
WA_ARBPL_ARC_STR-ZGR01 sy-vline
WA_ARBPL_ARC_STR-ZGR01_REF sy-vline
WA_ARBPL_ARC_STR-ZGR02 sy-vline
WA_ARBPL_ARC_STR-ZGR02_REF sy-vline
WA_ARBPL_ARC_STR-ZGR03 sy-vline
WA_ARBPL_ARC_STR-ZGR03_REF sy-vline
WA_ARBPL_ARC_STR-ZGR04 sy-vline
WA_ARBPL_ARC_STR-ZGR04_REF sy-vline
WA_ARBPL_ARC_STR-ZGR05 sy-vline
WA_ARBPL_ARC_STR-ZGR05_REF sy-vline
WA_ARBPL_ARC_STR-ZGR06 sy-vline
WA_ARBPL_ARC_STR-ZGR06_REF sy-vline
WA_ARBPL_ARC_STR-ZEIWM sy-vline
WA_ARBPL_ARC_STR-ZEIWN sy-vline
WA_ARBPL_ARC_STR-ZWMIN sy-vline
WA_ARBPL_ARC_STR-ZWNOR sy-vline
WA_ARBPL_ARC_STR-HR sy-vline
WA_ARBPL_ARC_STR-PRVBE sy-vline
WA_ARBPL_ARC_STR-SUBSYS sy-vline
WA_ARBPL_ARC_STR-BDEGR sy-vline
WA_ARBPL_ARC_STR-RGEKZ sy-vline
WA_ARBPL_ARC_STR-SLWID sy-vline
WA_ARBPL_ARC_STR-LIFNR sy-vline
WA_ARBPL_ARC_STR-SLWID_REF sy-vline
WA_ARBPL_ARC_STR-LIFNR_REF sy-vline
WA_ARBPL_ARC_STR-FLG_AFR sy-vline
WA_ARBPL_ARC_STR-ISTBED_KZ sy-vline
WA_ARBPL_ARC_STR-PRZ01 sy-vline
WA_ARBPL_ARC_STR-PRZ01_REF sy-vline
WA_ARBPL_ARC_STR-ACTXY1 sy-vline
WA_ARBPL_ARC_STR-ACTXK1 sy-vline
WA_ARBPL_ARC_STR-LEINH1 sy-vline
WA_ARBPL_ARC_STR-BDE1 sy-vline
WA_ARBPL_ARC_STR-SAKL1 sy-vline
WA_ARBPL_ARC_STR-ACTXY2 sy-vline
WA_ARBPL_ARC_STR-ACTXK2 sy-vline
WA_ARBPL_ARC_STR-LEINH2 sy-vline
WA_ARBPL_ARC_STR-BDE2 sy-vline
WA_ARBPL_ARC_STR-SAKL2 sy-vline
WA_ARBPL_ARC_STR-ACTXY3 sy-vline
WA_ARBPL_ARC_STR-ACTXK3 sy-vline
WA_ARBPL_ARC_STR-LEINH3 sy-vline
WA_ARBPL_ARC_STR-BDE3 sy-vline
WA_ARBPL_ARC_STR-SAKL3 sy-vline
WA_ARBPL_ARC_STR-ACTXY4 sy-vline
WA_ARBPL_ARC_STR-ACTXK4 sy-vline
WA_ARBPL_ARC_STR-LEINH4 sy-vline
WA_ARBPL_ARC_STR-BDE4 sy-vline
WA_ARBPL_ARC_STR-SAKL4 sy-vline
WA_ARBPL_ARC_STR-ACTXY5 sy-vline
WA_ARBPL_ARC_STR-ACTXK5 sy-vline
WA_ARBPL_ARC_STR-LEINH5 sy-vline
WA_ARBPL_ARC_STR-BDE5 sy-vline
WA_ARBPL_ARC_STR-SAKL5 sy-vline
WA_ARBPL_ARC_STR-ACTXY6 sy-vline
WA_ARBPL_ARC_STR-ACTXK6 sy-vline
WA_ARBPL_ARC_STR-LEINH6 sy-vline
WA_ARBPL_ARC_STR-BDE6 sy-vline
WA_ARBPL_ARC_STR-SAKL6 sy-vline
WA_ARBPL_ARC_STR-BDEP sy-vline
WA_ARBPL_ARC_STR-SAKLP sy-vline
WA_ARBPL_ARC_STR-CLASSNAME sy-vline
WA_ARBPL_ARC_STR-CLASS_DES sy-vline
WA_ARBPL_ARC_STR-CLASSCAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.