ABAP Select data from SAP table ARBERP_V_CCTR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ARBERP_V_CCTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ARBERP_V_CCTR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ARBERP_V_CCTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ARBERP_V_CCTR TYPE STANDARD TABLE OF ARBERP_V_CCTR,
      WA_ARBERP_V_CCTR TYPE ARBERP_V_CCTR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ARBERP_V_CCTR> TYPE ARBERP_V_CCTR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ARBERP_V_CCTR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ARBERP_V_CCTR
  INTO TABLE IT_ARBERP_V_CCTR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ARBERP_V_CCTR
*  INTO TABLE @DATA(IT_ARBERP_V_CCTR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ARBERP_V_CCTR INDEX 1 INTO DATA(WA_ARBERP_V_CCTR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ARBERP_V_CCTR ASSIGNING <ARBERP_V_CCTR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ARBERP_V_CCTR>-MANDT = 1.
<ARBERP_V_CCTR>-KOKRS = 1.
<ARBERP_V_CCTR>-KOSTL = 1.
<ARBERP_V_CCTR>-DATBI = 1.
<ARBERP_V_CCTR>-DATAB = 1.
ENDLOOP.

LOOP AT IT_ARBERP_V_CCTR INTO WA_ARBERP_V_CCTR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ARBERP_V_CCTR-BKZKP, sy-vline,
WA_ARBERP_V_CCTR-PKZKP, sy-vline,
WA_ARBERP_V_CCTR-BUKRS, sy-vline,
WA_ARBERP_V_CCTR-GSBER, sy-vline,
WA_ARBERP_V_CCTR-KOSAR, sy-vline,
WA_ARBERP_V_CCTR-VERAK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ARBERP_V_CCTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ARBERP_V_CCTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ARBERP_V_CCTR INTO WA_ARBERP_V_CCTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ARBERP_V_CCTR-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBERP_V_CCTR-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ARBERP_V_CCTR-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBERP_V_CCTR-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYSTEM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_ARBERP_V_CCTR-LOGSYSTEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ARBERP_V_CCTR-LOGSYSTEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ARBERP_V_CCTR_STR,
MANDT TYPE STRING,
KOKRS TYPE STRING,
KOSTL TYPE STRING,
DATBI TYPE STRING,
DATAB TYPE STRING,
BKZKP TYPE STRING,
PKZKP TYPE STRING,
BUKRS TYPE STRING,
GSBER TYPE STRING,
KOSAR TYPE STRING,
VERAK TYPE STRING,
VERAK_USER TYPE STRING,
WAERS TYPE STRING,
KALSM TYPE STRING,
TXJCD TYPE STRING,
PRCTR TYPE STRING,
WERKS TYPE STRING,
LOGSYSTEM TYPE STRING,
ERSDA TYPE STRING,
USNAM TYPE STRING,
BKZKS TYPE STRING,
BKZER TYPE STRING,
BKZOB TYPE STRING,
PKZKS TYPE STRING,
PKZER TYPE STRING,
VMETH TYPE STRING,
MGEFL TYPE STRING,
ABTEI TYPE STRING,
KOSZSCHL TYPE STRING,
KHINR TYPE STRING,
CCKEY TYPE STRING,
KOMPL TYPE STRING,
STAKZ TYPE STRING,
OBJNR TYPE STRING,
FUNKT TYPE STRING,
AFUNK TYPE STRING,
CPI_TEMPL TYPE STRING,
CPD_TEMPL TYPE STRING,
FUNC_AREA TYPE STRING,
SCI_TEMPL TYPE STRING,
SCD_TEMPL TYPE STRING,
SKI_TEMPL TYPE STRING,
SKD_TEMPL TYPE STRING,END OF T_EKKO_STR. DATA: WA_ARBERP_V_CCTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ARBERP_V_CCTR_STR-MANDT sy-vline
WA_ARBERP_V_CCTR_STR-KOKRS sy-vline
WA_ARBERP_V_CCTR_STR-KOSTL sy-vline
WA_ARBERP_V_CCTR_STR-DATBI sy-vline
WA_ARBERP_V_CCTR_STR-DATAB sy-vline
WA_ARBERP_V_CCTR_STR-BKZKP sy-vline
WA_ARBERP_V_CCTR_STR-PKZKP sy-vline
WA_ARBERP_V_CCTR_STR-BUKRS sy-vline
WA_ARBERP_V_CCTR_STR-GSBER sy-vline
WA_ARBERP_V_CCTR_STR-KOSAR sy-vline
WA_ARBERP_V_CCTR_STR-VERAK sy-vline
WA_ARBERP_V_CCTR_STR-VERAK_USER sy-vline
WA_ARBERP_V_CCTR_STR-WAERS sy-vline
WA_ARBERP_V_CCTR_STR-KALSM sy-vline
WA_ARBERP_V_CCTR_STR-TXJCD sy-vline
WA_ARBERP_V_CCTR_STR-PRCTR sy-vline
WA_ARBERP_V_CCTR_STR-WERKS sy-vline
WA_ARBERP_V_CCTR_STR-LOGSYSTEM sy-vline
WA_ARBERP_V_CCTR_STR-ERSDA sy-vline
WA_ARBERP_V_CCTR_STR-USNAM sy-vline
WA_ARBERP_V_CCTR_STR-BKZKS sy-vline
WA_ARBERP_V_CCTR_STR-BKZER sy-vline
WA_ARBERP_V_CCTR_STR-BKZOB sy-vline
WA_ARBERP_V_CCTR_STR-PKZKS sy-vline
WA_ARBERP_V_CCTR_STR-PKZER sy-vline
WA_ARBERP_V_CCTR_STR-VMETH sy-vline
WA_ARBERP_V_CCTR_STR-MGEFL sy-vline
WA_ARBERP_V_CCTR_STR-ABTEI sy-vline
WA_ARBERP_V_CCTR_STR-KOSZSCHL sy-vline
WA_ARBERP_V_CCTR_STR-KHINR sy-vline
WA_ARBERP_V_CCTR_STR-CCKEY sy-vline
WA_ARBERP_V_CCTR_STR-KOMPL sy-vline
WA_ARBERP_V_CCTR_STR-STAKZ sy-vline
WA_ARBERP_V_CCTR_STR-OBJNR sy-vline
WA_ARBERP_V_CCTR_STR-FUNKT sy-vline
WA_ARBERP_V_CCTR_STR-AFUNK sy-vline
WA_ARBERP_V_CCTR_STR-CPI_TEMPL sy-vline
WA_ARBERP_V_CCTR_STR-CPD_TEMPL sy-vline
WA_ARBERP_V_CCTR_STR-FUNC_AREA sy-vline
WA_ARBERP_V_CCTR_STR-SCI_TEMPL sy-vline
WA_ARBERP_V_CCTR_STR-SCD_TEMPL sy-vline
WA_ARBERP_V_CCTR_STR-SKI_TEMPL sy-vline
WA_ARBERP_V_CCTR_STR-SKD_TEMPL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.