ABAP Select data from SAP table AQTXTBS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP AQTXTBS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to AQTXTBS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the AQTXTBS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_AQTXTBS TYPE STANDARD TABLE OF AQTXTBS,
      WA_AQTXTBS TYPE AQTXTBS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <AQTXTBS> TYPE AQTXTBS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_AQTXTBS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM AQTXTBS
  INTO TABLE IT_AQTXTBS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM AQTXTBS
*  INTO TABLE @DATA(IT_AQTXTBS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_AQTXTBS INDEX 1 INTO DATA(WA_AQTXTBS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_AQTXTBS ASSIGNING <AQTXTBS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<AQTXTBS>-LANGU = 1.
<AQTXTBS>-SCFLAG = 1.
<AQTXTBS>-CLASS = 1.
<AQTXTBS>-OBJECT = 1.
<AQTXTBS>-EXPCLT = 1.
ENDLOOP.

LOOP AT IT_AQTXTBS INTO WA_AQTXTBS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_AQTXTBS-EXPSYS, sy-vline,
WA_AQTXTBS-TPOOL, sy-vline,
WA_AQTXTBS-TINDX, sy-vline,
WA_AQTXTBS-APPL, sy-vline,
WA_AQTXTBS-CCNT, sy-vline,
WA_AQTXTBS-MAXL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_AQTXTBS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_AQTXTBS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_AQTXTBS INTO WA_AQTXTBS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_AQTXTBS-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AQTXTBS-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_AQTXTBS_STR,
LANGU TYPE STRING,
SCFLAG TYPE STRING,
CLASS TYPE STRING,
OBJECT TYPE STRING,
EXPCLT TYPE STRING,
EXPSYS TYPE STRING,
TPOOL TYPE STRING,
TINDX TYPE STRING,
APPL TYPE STRING,
CCNT TYPE STRING,
MAXL TYPE STRING,
TEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_AQTXTBS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_AQTXTBS_STR-LANGU sy-vline
WA_AQTXTBS_STR-SCFLAG sy-vline
WA_AQTXTBS_STR-CLASS sy-vline
WA_AQTXTBS_STR-OBJECT sy-vline
WA_AQTXTBS_STR-EXPCLT sy-vline
WA_AQTXTBS_STR-EXPSYS sy-vline
WA_AQTXTBS_STR-TPOOL sy-vline
WA_AQTXTBS_STR-TINDX sy-vline
WA_AQTXTBS_STR-APPL sy-vline
WA_AQTXTBS_STR-CCNT sy-vline
WA_AQTXTBS_STR-MAXL sy-vline
WA_AQTXTBS_STR-TEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.