ABAP Select data from SAP table AQS_TRUITE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP AQS_TRUITE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to AQS_TRUITE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the AQS_TRUITE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_AQS_TRUITE TYPE STANDARD TABLE OF AQS_TRUITE,
      WA_AQS_TRUITE TYPE AQS_TRUITE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <AQS_TRUITE> TYPE AQS_TRUITE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_AQS_TRUITE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM AQS_TRUITE
  INTO TABLE IT_AQS_TRUITE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM AQS_TRUITE
*  INTO TABLE @DATA(IT_AQS_TRUITE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_AQS_TRUITE INDEX 1 INTO DATA(WA_AQS_TRUITE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_AQS_TRUITE ASSIGNING <AQS_TRUITE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<AQS_TRUITE>-NODE_KEY = 1.
<AQS_TRUITE>-ITEM_NAME = 1.
<AQS_TRUITE>-CLASS = 1.
<AQS_TRUITE>-FONT = 1.
<AQS_TRUITE>-DISABLED = 1.
ENDLOOP.

LOOP AT IT_AQS_TRUITE INTO WA_AQS_TRUITE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_AQS_TRUITE-EDITABLE, sy-vline,
WA_AQS_TRUITE-HIDDEN, sy-vline,
WA_AQS_TRUITE-ALIGNMENT, sy-vline,
WA_AQS_TRUITE-T_IMAGE, sy-vline,
WA_AQS_TRUITE-CHOSEN, sy-vline,
WA_AQS_TRUITE-TOGG_RIGHT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_AQS_TRUITE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_AQS_TRUITE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_AQS_TRUITE INTO WA_AQS_TRUITE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_AQS_TRUITE_STR,
NODE_KEY TYPE STRING,
ITEM_NAME TYPE STRING,
CLASS TYPE STRING,
FONT TYPE STRING,
DISABLED TYPE STRING,
EDITABLE TYPE STRING,
HIDDEN TYPE STRING,
ALIGNMENT TYPE STRING,
T_IMAGE TYPE STRING,
CHOSEN TYPE STRING,
TOGG_RIGHT TYPE STRING,
STYLE TYPE STRING,
LENGTH TYPE STRING,
LENGTH_PIX TYPE STRING,
IGNOREIMAG TYPE STRING,
USEBGCOLOR TYPE STRING,
TXTISQINFO TYPE STRING,
U_ALL TYPE STRING,
U_FONT TYPE STRING,
U_DISABLED TYPE STRING,
U_EDITABLE TYPE STRING,
U_HIDDEN TYPE STRING,
U_ALIGNMEN TYPE STRING,
U_T_IMAGE TYPE STRING,
U_CHOSEN TYPE STRING,
U_STYLE TYPE STRING,
U_TEXT TYPE STRING,
U_LENGTH TYPE STRING,
U_LENGTH_P TYPE STRING,
TEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_AQS_TRUITE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_AQS_TRUITE_STR-NODE_KEY sy-vline
WA_AQS_TRUITE_STR-ITEM_NAME sy-vline
WA_AQS_TRUITE_STR-CLASS sy-vline
WA_AQS_TRUITE_STR-FONT sy-vline
WA_AQS_TRUITE_STR-DISABLED sy-vline
WA_AQS_TRUITE_STR-EDITABLE sy-vline
WA_AQS_TRUITE_STR-HIDDEN sy-vline
WA_AQS_TRUITE_STR-ALIGNMENT sy-vline
WA_AQS_TRUITE_STR-T_IMAGE sy-vline
WA_AQS_TRUITE_STR-CHOSEN sy-vline
WA_AQS_TRUITE_STR-TOGG_RIGHT sy-vline
WA_AQS_TRUITE_STR-STYLE sy-vline
WA_AQS_TRUITE_STR-LENGTH sy-vline
WA_AQS_TRUITE_STR-LENGTH_PIX sy-vline
WA_AQS_TRUITE_STR-IGNOREIMAG sy-vline
WA_AQS_TRUITE_STR-USEBGCOLOR sy-vline
WA_AQS_TRUITE_STR-TXTISQINFO sy-vline
WA_AQS_TRUITE_STR-U_ALL sy-vline
WA_AQS_TRUITE_STR-U_FONT sy-vline
WA_AQS_TRUITE_STR-U_DISABLED sy-vline
WA_AQS_TRUITE_STR-U_EDITABLE sy-vline
WA_AQS_TRUITE_STR-U_HIDDEN sy-vline
WA_AQS_TRUITE_STR-U_ALIGNMEN sy-vline
WA_AQS_TRUITE_STR-U_T_IMAGE sy-vline
WA_AQS_TRUITE_STR-U_CHOSEN sy-vline
WA_AQS_TRUITE_STR-U_STYLE sy-vline
WA_AQS_TRUITE_STR-U_TEXT sy-vline
WA_AQS_TRUITE_STR-U_LENGTH sy-vline
WA_AQS_TRUITE_STR-U_LENGTH_P sy-vline
WA_AQS_TRUITE_STR-TEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.