ABAP Select data from SAP table APPLSEF_MAINTCON_CRT_RQ_SYNC into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP APPLSEF_MAINTCON_CRT_RQ_SYNC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to APPLSEF_MAINTCON_CRT_RQ_SYNC. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the APPLSEF_MAINTCON_CRT_RQ_SYNC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_APPLSEF_MAINTCON_CRT_RQ_SYNC TYPE STANDARD TABLE OF APPLSEF_MAINTCON_CRT_RQ_SYNC, WA_APPLSEF_MAINTCON_CRT_RQ_SYNC TYPE APPLSEF_MAINTCON_CRT_RQ_SYNC, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <APPLSEF_MAINTCON_CRT_RQ_SYNC> TYPE APPLSEF_MAINTCON_CRT_RQ_SYNC. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_APPLSEF_MAINTCON_CRT_RQ_SYNC. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM APPLSEF_MAINTCON_CRT_RQ_SYNC INTO TABLE IT_APPLSEF_MAINTCON_CRT_RQ_SYNC. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM APPLSEF_MAINTCON_CRT_RQ_SYNC * INTO TABLE @DATA(IT_APPLSEF_MAINTCON_CRT_RQ_SYNC2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_APPLSEF_MAINTCON_CRT_RQ_SYNC INDEX 1 INTO DATA(WA_APPLSEF_MAINTCON_CRT_RQ_SYNC2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_APPLSEF_MAINTCON_CRT_RQ_SYNC ASSIGNING <APPLSEF_MAINTCON_CRT_RQ_SYNC>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<APPLSEF_MAINTCON_CRT_RQ_SYNC>-CONTROLLER = 1.
<APPLSEF_MAINTCON_CRT_RQ_SYNC>-MESSAGE_HEADER = 1.
<APPLSEF_MAINTCON_CRT_RQ_SYNC>-CONTROLLER = 1.
<APPLSEF_MAINTCON_CRT_RQ_SYNC>-ID = 1.
<APPLSEF_MAINTCON_CRT_RQ_SYNC>-CONTROLLER = 1.
ENDLOOP. LOOP AT IT_APPLSEF_MAINTCON_CRT_RQ_SYNC INTO WA_APPLSEF_MAINTCON_CRT_RQ_SYNC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_APPLSEF_MAINTCON_CRT_RQ_SYNC-SCHEME_ID, sy-vline,
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC-SCHEME_AGENCY_ID, sy-vline,
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC-SCHEME_AGENCY_SCHEME_AGENCY_ID, sy-vline,
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC-VALUE, sy-vline,
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC-UUID, sy-vline,
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC-REFERENCE_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_APPLSEF_MAINTCON_CRT_RQ_SYNC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_APPLSEF_MAINTCON_CRT_RQ_SYNC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_APPLSEF_MAINTCON_CRT_RQ_SYNC INTO WA_APPLSEF_MAINTCON_CRT_RQ_SYNC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR,
CONTROLLER TYPE STRING,
MESSAGE_HEADER TYPE STRING,
CONTROLLER TYPE STRING,
ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
SCHEME_AGENCY_SCHEME_AGENCY_ID TYPE STRING,
VALUE TYPE STRING,
UUID TYPE STRING,
REFERENCE_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
SCHEME_AGENCY_SCHEME_AGENCY_ID TYPE STRING,
VALUE TYPE STRING,
REFERENCE_UUID TYPE STRING,
MAINTENANCE_CONFIRMATION TYPE STRING,
CONTROLLER TYPE STRING,
MAINTENANCE_ORDER_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
VALUE TYPE STRING,
ORDER_OPERATION_ID TYPE STRING,
ORDER_OPERATION_ACTIVITY_ID TYPE STRING,
CAPACITY_CATEGORY_CODE TYPE STRING,
CAPACITY_SPLIT_ID TYPE STRING,
WORK_CENTRE_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
VALUE TYPE STRING,
WORK_CENTRE_PLANT_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
VALUE TYPE STRING,
RESOURCE_CLASS_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
VALUE TYPE STRING,
ACTUAL_WORK_QUANTITY TYPE STRING,
CONTROLLER TYPE STRING,
UNIT_CODE TYPE STRING,
VALUE TYPE STRING,
REMAINING_WORK_QUANTITY TYPE STRING,
CONTROLLER TYPE STRING,
UNIT_CODE TYPE STRING,
VALUE TYPE STRING,
FORECAST_END_DATE_TIME TYPE STRING,
TIME_CONFIRMATION_STATUS_CODE TYPE STRING,
ACTUAL_EXECUTION_PERIOD TYPE STRING,
CONTROLLER TYPE STRING,
START_DATE_TIME TYPE STRING,
END_DATE_TIME TYPE STRING,
WORK_AGREEMENT_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
VALUE TYPE STRING,
WORK_COMPLETED_INDICATOR TYPE STRING,
DESCRIPTION TYPE STRING,
CONTROLLER TYPE STRING,
LANGUAGE_CODE TYPE STRING,
VALUE TYPE STRING,
LINEAR_INFORMATION TYPE STRING,
CONTROLLER TYPE STRING,
START_LINEAR_TECHNICAL_ASSET_M TYPE STRING,
END_LINEAR_TECHNICAL_ASSET_MAR TYPE STRING,
START_POINT_MEASURE TYPE STRING,
CONTROLLER TYPE STRING,
UNIT_CODE TYPE STRING,
VALUE TYPE STRING,
END_POINT_MEASURE TYPE STRING,
CONTROLLER TYPE STRING,
UNIT_CODE TYPE STRING,
VALUE TYPE STRING,
LENGTH_MEASURE TYPE STRING,
CONTROLLER TYPE STRING,
UNIT_CODE TYPE STRING,
VALUE TYPE STRING,
START_MARKER_LENGTH_MEASURE TYPE STRING,
CONTROLLER TYPE STRING,
UNIT_CODE TYPE STRING,
VALUE TYPE STRING,
END_MARKER_LENGTH_MEASURE TYPE STRING,
CONTROLLER TYPE STRING,
UNIT_CODE TYPE STRING,
VALUE TYPE STRING,
FIRST_OFFSET TYPE STRING,
CONTROLLER TYPE STRING,
TECHNICAL_ASSET_POSITION_OFFSE TYPE STRING,
MEASURE TYPE STRING,
CONTROLLER TYPE STRING,
UNIT_CODE TYPE STRING,
VALUE TYPE STRING,
SECOND_OFFSET TYPE STRING,
CONTROLLER TYPE STRING,
TECHNICAL_ASSET_POSITION_OFFSE TYPE STRING,
MEASURE TYPE STRING,
CONTROLLER TYPE STRING,
UNIT_CODE TYPE STRING,
VALUE TYPE STRING,END OF T_EKKO_STR. DATA: WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-MESSAGE_HEADER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SCHEME_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SCHEME_AGENCY_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SCHEME_AGENCY_SCHEME_AGENCY_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-UUID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-REFERENCE_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SCHEME_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SCHEME_AGENCY_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SCHEME_AGENCY_SCHEME_AGENCY_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-REFERENCE_UUID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-MAINTENANCE_CONFIRMATION sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-MAINTENANCE_ORDER_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SCHEME_AGENCY_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-ORDER_OPERATION_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-ORDER_OPERATION_ACTIVITY_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CAPACITY_CATEGORY_CODE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CAPACITY_SPLIT_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-WORK_CENTRE_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SCHEME_AGENCY_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-WORK_CENTRE_PLANT_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SCHEME_AGENCY_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-RESOURCE_CLASS_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SCHEME_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SCHEME_AGENCY_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-ACTUAL_WORK_QUANTITY sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-UNIT_CODE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-REMAINING_WORK_QUANTITY sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-UNIT_CODE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-FORECAST_END_DATE_TIME sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-TIME_CONFIRMATION_STATUS_CODE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-ACTUAL_EXECUTION_PERIOD sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-START_DATE_TIME sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-END_DATE_TIME sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-WORK_AGREEMENT_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SCHEME_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SCHEME_AGENCY_ID sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-WORK_COMPLETED_INDICATOR sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-DESCRIPTION sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-LANGUAGE_CODE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-LINEAR_INFORMATION sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-START_LINEAR_TECHNICAL_ASSET_M sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-END_LINEAR_TECHNICAL_ASSET_MAR sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-START_POINT_MEASURE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-UNIT_CODE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-END_POINT_MEASURE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-UNIT_CODE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-LENGTH_MEASURE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-UNIT_CODE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-START_MARKER_LENGTH_MEASURE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-UNIT_CODE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-END_MARKER_LENGTH_MEASURE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-UNIT_CODE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-FIRST_OFFSET sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-TECHNICAL_ASSET_POSITION_OFFSE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-MEASURE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-UNIT_CODE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-SECOND_OFFSET sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-TECHNICAL_ASSET_POSITION_OFFSE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-MEASURE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-CONTROLLER sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-UNIT_CODE sy-vline
WA_APPLSEF_MAINTCON_CRT_RQ_SYNC_STR-VALUE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.