ABAP Select data from SAP table APPLSEF_INSTALLATION_POINT_E20 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP APPLSEF_INSTALLATION_POINT_E20 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to APPLSEF_INSTALLATION_POINT_E20. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the APPLSEF_INSTALLATION_POINT_E20 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_APPLSEF_INSTALLATION_POINT_E20 TYPE STANDARD TABLE OF APPLSEF_INSTALLATION_POINT_E20,
      WA_APPLSEF_INSTALLATION_POINT_E20 TYPE APPLSEF_INSTALLATION_POINT_E20,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <APPLSEF_INSTALLATION_POINT_E20> TYPE APPLSEF_INSTALLATION_POINT_E20.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_APPLSEF_INSTALLATION_POINT_E20.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM APPLSEF_INSTALLATION_POINT_E20
  INTO TABLE IT_APPLSEF_INSTALLATION_POINT_E20.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM APPLSEF_INSTALLATION_POINT_E20
*  INTO TABLE @DATA(IT_APPLSEF_INSTALLATION_POINT_E202).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_APPLSEF_INSTALLATION_POINT_E20 INDEX 1 INTO DATA(WA_APPLSEF_INSTALLATION_POINT_E202).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_APPLSEF_INSTALLATION_POINT_E20 ASSIGNING <APPLSEF_INSTALLATION_POINT_E20>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<APPLSEF_INSTALLATION_POINT_E20>-CONTROLLER = 1.
<APPLSEF_INSTALLATION_POINT_E20>-HOUSE_ID = 1.
<APPLSEF_INSTALLATION_POINT_E20>-STREET_NAME = 1.
<APPLSEF_INSTALLATION_POINT_E20>-STREET_POSTAL_CODE = 1.
<APPLSEF_INSTALLATION_POINT_E20>-CITY_NAME = 1.
ENDLOOP.

LOOP AT IT_APPLSEF_INSTALLATION_POINT_E20 INTO WA_APPLSEF_INSTALLATION_POINT_E20.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_APPLSEF_INSTALLATION_POINT_E20-CONTROLLER, sy-vline,
WA_APPLSEF_INSTALLATION_POINT_E20-LANGUAGE_CODE, sy-vline,
WA_APPLSEF_INSTALLATION_POINT_E20-VALUE, sy-vline,
WA_APPLSEF_INSTALLATION_POINT_E20-COUNTRY_CODE, sy-vline,
WA_APPLSEF_INSTALLATION_POINT_E20-TELEPHONE, sy-vline,
WA_APPLSEF_INSTALLATION_POINT_E20-CONTROLLER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_APPLSEF_INSTALLATION_POINT_E20 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_APPLSEF_INSTALLATION_POINT_E20 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_APPLSEF_INSTALLATION_POINT_E20 INTO WA_APPLSEF_INSTALLATION_POINT_E20. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_APPLSEF_INSTALLATION_POINT_E20_STR,
CONTROLLER TYPE STRING,
HOUSE_ID TYPE STRING,
STREET_NAME TYPE STRING,
STREET_POSTAL_CODE TYPE STRING,
CITY_NAME TYPE STRING,
CONTROLLER TYPE STRING,
LANGUAGE_CODE TYPE STRING,
VALUE TYPE STRING,
COUNTRY_CODE TYPE STRING,
TELEPHONE TYPE STRING,
CONTROLLER TYPE STRING,
NUMBER TYPE STRING,
CONTROLLER TYPE STRING,
AREA_ID TYPE STRING,
SUBSCRIBER_ID TYPE STRING,
EXTENSION_ID TYPE STRING,
COUNTRY_CODE TYPE STRING,
COUNTRY_DIALLING_CODE TYPE STRING,
COUNTRY_NAME TYPE STRING,
CONTROLLER TYPE STRING,
LANGUAGE_CODE TYPE STRING,
VALUE TYPE STRING,
SMSENABLED_INDICATOR TYPE STRING,
NUMBER_DEFAULT_INDICATOR TYPE STRING,
NUMBER_DESCRIPTION TYPE STRING,
NUMBER_USAGE_DENIAL_INDICATOR TYPE STRING,END OF T_EKKO_STR. DATA: WA_APPLSEF_INSTALLATION_POINT_E20_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-CONTROLLER sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-HOUSE_ID sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-STREET_NAME sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-STREET_POSTAL_CODE sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-CITY_NAME sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-CONTROLLER sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-LANGUAGE_CODE sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-VALUE sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-COUNTRY_CODE sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-TELEPHONE sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-CONTROLLER sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-NUMBER sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-CONTROLLER sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-AREA_ID sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-SUBSCRIBER_ID sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-EXTENSION_ID sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-COUNTRY_CODE sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-COUNTRY_DIALLING_CODE sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-COUNTRY_NAME sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-CONTROLLER sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-LANGUAGE_CODE sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-VALUE sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-SMSENABLED_INDICATOR sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-NUMBER_DEFAULT_INDICATOR sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-NUMBER_DESCRIPTION sy-vline
WA_APPLSEF_INSTALLATION_POINT_E20_STR-NUMBER_USAGE_DENIAL_INDICATOR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.