ABAP Select data from SAP table AFX_STR_WRITE_PP_DETAIL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP AFX_STR_WRITE_PP_DETAIL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to AFX_STR_WRITE_PP_DETAIL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the AFX_STR_WRITE_PP_DETAIL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_AFX_STR_WRITE_PP_DETAIL TYPE STANDARD TABLE OF AFX_STR_WRITE_PP_DETAIL,
      WA_AFX_STR_WRITE_PP_DETAIL TYPE AFX_STR_WRITE_PP_DETAIL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <AFX_STR_WRITE_PP_DETAIL> TYPE AFX_STR_WRITE_PP_DETAIL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_AFX_STR_WRITE_PP_DETAIL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM AFX_STR_WRITE_PP_DETAIL
  INTO TABLE IT_AFX_STR_WRITE_PP_DETAIL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM AFX_STR_WRITE_PP_DETAIL
*  INTO TABLE @DATA(IT_AFX_STR_WRITE_PP_DETAIL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_AFX_STR_WRITE_PP_DETAIL INDEX 1 INTO DATA(WA_AFX_STR_WRITE_PP_DETAIL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_AFX_STR_WRITE_PP_DETAIL ASSIGNING <AFX_STR_WRITE_PP_DETAIL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<AFX_STR_WRITE_PP_DETAIL>-OBJECT = 1.
<AFX_STR_WRITE_PP_DETAIL>-APPLCATG = 1.
<AFX_STR_WRITE_PP_DETAIL>-STRU_EXTPPKEY = 1.
<AFX_STR_WRITE_PP_DETAIL>-TTYP_DBPACK = 1.
<AFX_STR_WRITE_PP_DETAIL>-STRU_DBPACK = 1.
ENDLOOP.

LOOP AT IT_AFX_STR_WRITE_PP_DETAIL INTO WA_AFX_STR_WRITE_PP_DETAIL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_AFX_STR_WRITE_PP_DETAIL-FMOD_PACKAGE_GET, sy-vline,
WA_AFX_STR_WRITE_PP_DETAIL-FMOD_ETOI, sy-vline,
WA_AFX_STR_WRITE_PP_DETAIL-FMOD_ITOE, sy-vline,
WA_AFX_STR_WRITE_PP_DETAIL-FMOD_WTAB_CREATE, sy-vline,
WA_AFX_STR_WRITE_PP_DETAIL-FLG_DYN_PB_IN_PP, sy-vline,
WA_AFX_STR_WRITE_PP_DETAIL-LEAD_TAB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_AFX_STR_WRITE_PP_DETAIL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_AFX_STR_WRITE_PP_DETAIL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_AFX_STR_WRITE_PP_DETAIL INTO WA_AFX_STR_WRITE_PP_DETAIL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_AFX_STR_WRITE_PP_DETAIL_STR,
OBJECT TYPE STRING,
APPLCATG TYPE STRING,
STRU_EXTPPKEY TYPE STRING,
TTYP_DBPACK TYPE STRING,
STRU_DBPACK TYPE STRING,
FMOD_PACKAGE_GET TYPE STRING,
FMOD_ETOI TYPE STRING,
FMOD_ITOE TYPE STRING,
FMOD_WTAB_CREATE TYPE STRING,
FLG_DYN_PB_IN_PP TYPE STRING,
LEAD_TAB TYPE STRING,
INCL_NAME_WRITE_PART TYPE STRING,
TAB_STRUCDEF_X TYPE STRING,END OF T_EKKO_STR. DATA: WA_AFX_STR_WRITE_PP_DETAIL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_AFX_STR_WRITE_PP_DETAIL_STR-OBJECT sy-vline
WA_AFX_STR_WRITE_PP_DETAIL_STR-APPLCATG sy-vline
WA_AFX_STR_WRITE_PP_DETAIL_STR-STRU_EXTPPKEY sy-vline
WA_AFX_STR_WRITE_PP_DETAIL_STR-TTYP_DBPACK sy-vline
WA_AFX_STR_WRITE_PP_DETAIL_STR-STRU_DBPACK sy-vline
WA_AFX_STR_WRITE_PP_DETAIL_STR-FMOD_PACKAGE_GET sy-vline
WA_AFX_STR_WRITE_PP_DETAIL_STR-FMOD_ETOI sy-vline
WA_AFX_STR_WRITE_PP_DETAIL_STR-FMOD_ITOE sy-vline
WA_AFX_STR_WRITE_PP_DETAIL_STR-FMOD_WTAB_CREATE sy-vline
WA_AFX_STR_WRITE_PP_DETAIL_STR-FLG_DYN_PB_IN_PP sy-vline
WA_AFX_STR_WRITE_PP_DETAIL_STR-LEAD_TAB sy-vline
WA_AFX_STR_WRITE_PP_DETAIL_STR-INCL_NAME_WRITE_PART sy-vline
WA_AFX_STR_WRITE_PP_DETAIL_STR-TAB_STRUCDEF_X sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.