ABAP Select data from SAP table AFWGO_CONTROL_PARAMETER2 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP AFWGO_CONTROL_PARAMETER2 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to AFWGO_CONTROL_PARAMETER2. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the AFWGO_CONTROL_PARAMETER2 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_AFWGO_CONTROL_PARAMETER2 TYPE STANDARD TABLE OF AFWGO_CONTROL_PARAMETER2,
      WA_AFWGO_CONTROL_PARAMETER2 TYPE AFWGO_CONTROL_PARAMETER2,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <AFWGO_CONTROL_PARAMETER2> TYPE AFWGO_CONTROL_PARAMETER2.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_AFWGO_CONTROL_PARAMETER2.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM AFWGO_CONTROL_PARAMETER2
  INTO TABLE IT_AFWGO_CONTROL_PARAMETER2.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM AFWGO_CONTROL_PARAMETER2
*  INTO TABLE @DATA(IT_AFWGO_CONTROL_PARAMETER22).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_AFWGO_CONTROL_PARAMETER2 INDEX 1 INTO DATA(WA_AFWGO_CONTROL_PARAMETER22).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_AFWGO_CONTROL_PARAMETER2 ASSIGNING <AFWGO_CONTROL_PARAMETER2>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<AFWGO_CONTROL_PARAMETER2>-EVALPROC2 = 1.
<AFWGO_CONTROL_PARAMETER2>-KEYDATE = 1.
<AFWGO_CONTROL_PARAMETER2>-APPLICATION = 1.
<AFWGO_CONTROL_PARAMETER2>-MODUS2 = 1.
<AFWGO_CONTROL_PARAMETER2>-STATUS2 = 1.
ENDLOOP.

LOOP AT IT_AFWGO_CONTROL_PARAMETER2 INTO WA_AFWGO_CONTROL_PARAMETER2.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_AFWGO_CONTROL_PARAMETER2-REF_LOG_HANDLE, sy-vline,
WA_AFWGO_CONTROL_PARAMETER2-FLG_SAP_SERVICE, sy-vline,
WA_AFWGO_CONTROL_PARAMETER2-FLG_FLID_TEST, sy-vline,
ENDLOOP. *Add any further fields from structure WA_AFWGO_CONTROL_PARAMETER2 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_AFWGO_CONTROL_PARAMETER2 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_AFWGO_CONTROL_PARAMETER2 INTO WA_AFWGO_CONTROL_PARAMETER2. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit 1CEP1, internal->external for field EVALPROC2 CALL FUNCTION 'CONVERSION_EXIT_1CEP1_OUTPUT' EXPORTING input = WA_AFWGO_CONTROL_PARAMETER2-EVALPROC2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AFWGO_CONTROL_PARAMETER2-EVALPROC2.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_AFWGO_CONTROL_PARAMETER2_STR,
EVALPROC2 TYPE STRING,
KEYDATE TYPE STRING,
APPLICATION TYPE STRING,
MODUS2 TYPE STRING,
STATUS2 TYPE STRING,
REF_LOG_HANDLE TYPE STRING,
FLG_SAP_SERVICE TYPE STRING,
FLG_FLID_TEST TYPE STRING,END OF T_EKKO_STR. DATA: WA_AFWGO_CONTROL_PARAMETER2_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_AFWGO_CONTROL_PARAMETER2_STR-EVALPROC2 sy-vline
WA_AFWGO_CONTROL_PARAMETER2_STR-KEYDATE sy-vline
WA_AFWGO_CONTROL_PARAMETER2_STR-APPLICATION sy-vline
WA_AFWGO_CONTROL_PARAMETER2_STR-MODUS2 sy-vline
WA_AFWGO_CONTROL_PARAMETER2_STR-STATUS2 sy-vline
WA_AFWGO_CONTROL_PARAMETER2_STR-REF_LOG_HANDLE sy-vline
WA_AFWGO_CONTROL_PARAMETER2_STR-FLG_SAP_SERVICE sy-vline
WA_AFWGO_CONTROL_PARAMETER2_STR-FLG_FLID_TEST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.