ABAP Select data from SAP table AEOI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP AEOI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to AEOI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the AEOI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_AEOI TYPE STANDARD TABLE OF AEOI,
      WA_AEOI TYPE AEOI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <AEOI> TYPE AEOI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_AEOI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM AEOI
  INTO TABLE IT_AEOI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM AEOI
*  INTO TABLE @DATA(IT_AEOI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_AEOI INDEX 1 INTO DATA(WA_AEOI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_AEOI ASSIGNING <AEOI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<AEOI>-MANDT = 1.
<AEOI>-AENNR = 1.
<AEOI>-AETYP = 1.
<AEOI>-OBJKT = 1.
<AEOI>-USOBJ = 1.
ENDLOOP.

LOOP AT IT_AEOI INTO WA_AEOI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_AEOI-CCVMS, sy-vline,
WA_AEOI-OITXT, sy-vline,
WA_AEOI-LTXSP, sy-vline,
WA_AEOI-AEDAT, sy-vline,
WA_AEOI-AENAM, sy-vline,
WA_AEOI-ANDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_AEOI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_AEOI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_AEOI INTO WA_AEOI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_AEOI-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AEOI-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LTXSP CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_AEOI-LTXSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AEOI-LTXSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit NUMCV, internal->external for field REVLV CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_AEOI-REVLV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_AEOI-REVLV.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_AEOI_STR,
MANDT TYPE STRING,
AENNR TYPE STRING,
AETYP TYPE STRING,
OBJKT TYPE STRING,
USOBJ TYPE STRING,
CCVMS TYPE STRING,
OITXT TYPE STRING,
LTXSP TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
ANDAT TYPE STRING,
ANNAM TYPE STRING,
OBJDT TYPE STRING,
OBJNM TYPE STRING,
CCLCK TYPE STRING,
AEOST TYPE STRING,
REVLV TYPE STRING,
AEDTZ TYPE STRING,
CCSTO TYPE STRING,
CCOAA TYPE STRING,
CONT1 TYPE STRING,
AEOI_GUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_AEOI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_AEOI_STR-MANDT sy-vline
WA_AEOI_STR-AENNR sy-vline
WA_AEOI_STR-AETYP sy-vline
WA_AEOI_STR-OBJKT sy-vline
WA_AEOI_STR-USOBJ sy-vline
WA_AEOI_STR-CCVMS sy-vline
WA_AEOI_STR-OITXT sy-vline
WA_AEOI_STR-LTXSP sy-vline
WA_AEOI_STR-AEDAT sy-vline
WA_AEOI_STR-AENAM sy-vline
WA_AEOI_STR-ANDAT sy-vline
WA_AEOI_STR-ANNAM sy-vline
WA_AEOI_STR-OBJDT sy-vline
WA_AEOI_STR-OBJNM sy-vline
WA_AEOI_STR-CCLCK sy-vline
WA_AEOI_STR-AEOST sy-vline
WA_AEOI_STR-REVLV sy-vline
WA_AEOI_STR-AEDTZ sy-vline
WA_AEOI_STR-CCSTO sy-vline
WA_AEOI_STR-CCOAA sy-vline
WA_AEOI_STR-CONT1 sy-vline
WA_AEOI_STR-AEOI_GUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.