ABAP Select data from SAP table ADPMPRIOSUB into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP ADPMPRIOSUB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to ADPMPRIOSUB. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the ADPMPRIOSUB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_ADPMPRIOSUB TYPE STANDARD TABLE OF ADPMPRIOSUB,
      WA_ADPMPRIOSUB TYPE ADPMPRIOSUB,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <ADPMPRIOSUB> TYPE ADPMPRIOSUB.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_ADPMPRIOSUB.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM ADPMPRIOSUB
  INTO TABLE IT_ADPMPRIOSUB.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM ADPMPRIOSUB
*  INTO TABLE @DATA(IT_ADPMPRIOSUB2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_ADPMPRIOSUB INDEX 1 INTO DATA(WA_ADPMPRIOSUB2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_ADPMPRIOSUB ASSIGNING <ADPMPRIOSUB>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<ADPMPRIOSUB>-MANDT = 1.
<ADPMPRIOSUB>-WERKS = 1.
<ADPMPRIOSUB>-ARBPL = 1.
<ADPMPRIOSUB>-ORCOD = 1.
<ADPMPRIOSUB>-PRKEY = 1.
ENDLOOP.

LOOP AT IT_ADPMPRIOSUB INTO WA_ADPMPRIOSUB.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_ADPMPRIOSUB-PRVAL, sy-vline,
WA_ADPMPRIOSUB-PRTME, sy-vline,
WA_ADPMPRIOSUB-TUNIT, sy-vline,
WA_ADPMPRIOSUB-FXQTY, sy-vline,
WA_ADPMPRIOSUB-PRFIX, sy-vline,
WA_ADPMPRIOSUB-STPCT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_ADPMPRIOSUB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_ADPMPRIOSUB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_ADPMPRIOSUB INTO WA_ADPMPRIOSUB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field TUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ADPMPRIOSUB-TUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ADPMPRIOSUB-TUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field TLUNT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_ADPMPRIOSUB-TLUNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_ADPMPRIOSUB-TLUNT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_ADPMPRIOSUB_STR,
MANDT TYPE STRING,
WERKS TYPE STRING,
ARBPL TYPE STRING,
ORCOD TYPE STRING,
PRKEY TYPE STRING,
PRVAL TYPE STRING,
PRTME TYPE STRING,
TUNIT TYPE STRING,
FXQTY TYPE STRING,
PRFIX TYPE STRING,
STPCT TYPE STRING,
STTYP TYPE STRING,
SBLCI TYPE STRING,
SUM1I TYPE STRING,
SQTYI TYPE STRING,
TLUNT TYPE STRING,
LROVL TYPE STRING,
LYOVL TYPE STRING,
LGOVL TYPE STRING,
BLOCK TYPE STRING,
TMPCT TYPE STRING,
RLPCT TYPE STRING,
YLPCT TYPE STRING,
GLPCT TYPE STRING,
LOOVL TYPE STRING,
OLPCT TYPE STRING,
SRBCI TYPE STRING,END OF T_EKKO_STR. DATA: WA_ADPMPRIOSUB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_ADPMPRIOSUB_STR-MANDT sy-vline
WA_ADPMPRIOSUB_STR-WERKS sy-vline
WA_ADPMPRIOSUB_STR-ARBPL sy-vline
WA_ADPMPRIOSUB_STR-ORCOD sy-vline
WA_ADPMPRIOSUB_STR-PRKEY sy-vline
WA_ADPMPRIOSUB_STR-PRVAL sy-vline
WA_ADPMPRIOSUB_STR-PRTME sy-vline
WA_ADPMPRIOSUB_STR-TUNIT sy-vline
WA_ADPMPRIOSUB_STR-FXQTY sy-vline
WA_ADPMPRIOSUB_STR-PRFIX sy-vline
WA_ADPMPRIOSUB_STR-STPCT sy-vline
WA_ADPMPRIOSUB_STR-STTYP sy-vline
WA_ADPMPRIOSUB_STR-SBLCI sy-vline
WA_ADPMPRIOSUB_STR-SUM1I sy-vline
WA_ADPMPRIOSUB_STR-SQTYI sy-vline
WA_ADPMPRIOSUB_STR-TLUNT sy-vline
WA_ADPMPRIOSUB_STR-LROVL sy-vline
WA_ADPMPRIOSUB_STR-LYOVL sy-vline
WA_ADPMPRIOSUB_STR-LGOVL sy-vline
WA_ADPMPRIOSUB_STR-BLOCK sy-vline
WA_ADPMPRIOSUB_STR-TMPCT sy-vline
WA_ADPMPRIOSUB_STR-RLPCT sy-vline
WA_ADPMPRIOSUB_STR-YLPCT sy-vline
WA_ADPMPRIOSUB_STR-GLPCT sy-vline
WA_ADPMPRIOSUB_STR-LOOVL sy-vline
WA_ADPMPRIOSUB_STR-OLPCT sy-vline
WA_ADPMPRIOSUB_STR-SRBCI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.