ABAP Select data from SAP table /UI2/FLC_OUTPUT_STRUC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /UI2/FLC_OUTPUT_STRUC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /UI2/FLC_OUTPUT_STRUC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /UI2/FLC_OUTPUT_STRUC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/UI2/FLC_OUTPUT_STRUC TYPE STANDARD TABLE OF /UI2/FLC_OUTPUT_STRUC,
      WA_/UI2/FLC_OUTPUT_STRUC TYPE /UI2/FLC_OUTPUT_STRUC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </UI2/FLC_OUTPUT_STRUC> TYPE /UI2/FLC_OUTPUT_STRUC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/UI2/FLC_OUTPUT_STRUC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /UI2/FLC_OUTPUT_STRUC
  INTO TABLE IT_/UI2/FLC_OUTPUT_STRUC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /UI2/FLC_OUTPUT_STRUC
*  INTO TABLE @DATA(IT_/UI2/FLC_OUTPUT_STRUC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/UI2/FLC_OUTPUT_STRUC INDEX 1 INTO DATA(WA_/UI2/FLC_OUTPUT_STRUC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/UI2/FLC_OUTPUT_STRUC ASSIGNING </UI2/FLC_OUTPUT_STRUC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</UI2/FLC_OUTPUT_STRUC>-ICON = 1.
</UI2/FLC_OUTPUT_STRUC>-OBJTYPE = 1.
</UI2/FLC_OUTPUT_STRUC>-DEVCLASS = 1.
</UI2/FLC_OUTPUT_STRUC>-SCOPE = 1.
</UI2/FLC_OUTPUT_STRUC>-CATALOG_ID = 1.
ENDLOOP.

LOOP AT IT_/UI2/FLC_OUTPUT_STRUC INTO WA_/UI2/FLC_OUTPUT_STRUC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/UI2/FLC_OUTPUT_STRUC-CATALOG_TITLE, sy-vline,
WA_/UI2/FLC_OUTPUT_STRUC-CATALOG_TITLE_TEXT_ID, sy-vline,
WA_/UI2/FLC_OUTPUT_STRUC-GROUP_ID, sy-vline,
WA_/UI2/FLC_OUTPUT_STRUC-GROUP_TITLE, sy-vline,
WA_/UI2/FLC_OUTPUT_STRUC-GROUP_TITLE_TEXT_ID, sy-vline,
WA_/UI2/FLC_OUTPUT_STRUC-SYSTEM_ALIAS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/UI2/FLC_OUTPUT_STRUC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/UI2/FLC_OUTPUT_STRUC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/UI2/FLC_OUTPUT_STRUC INTO WA_/UI2/FLC_OUTPUT_STRUC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/UI2/FLC_OUTPUT_STRUC_STR,
ICON TYPE STRING,
OBJTYPE TYPE STRING,
DEVCLASS TYPE STRING,
SCOPE TYPE STRING,
CATALOG_ID TYPE STRING,
CATALOG_TITLE TYPE STRING,
CATALOG_TITLE_TEXT_ID TYPE STRING,
GROUP_ID TYPE STRING,
GROUP_TITLE TYPE STRING,
GROUP_TITLE_TEXT_ID TYPE STRING,
SYSTEM_ALIAS TYPE STRING,
CHIP_TITLE TYPE STRING,
CHIP_ID TYPE STRING,
CHIP_ICON TYPE STRING,
CHIP_PARAMETER TYPE STRING,
KEYWORDS TYPE STRING,
CATALOG_REFERENCE_ID TYPE STRING,
TILE_REFERENCE_ID TYPE STRING,
TARGET_MAPPING_REFERENCE_ID TYPE STRING,
TARGET_MAPPING_INFORMATION TYPE STRING,
SAPUI5_TEXT TYPE STRING,
LPD_ROLE TYPE STRING,
LPD_INSTANCE TYPE STRING,
APP_TYPE TYPE STRING,
APPLICATION TYPE STRING,
LPD_GUID TYPE STRING,
LPD_ALIAS TYPE STRING,
LPD_ADD_INFO TYPE STRING,
LPD_TEXT_KEY TYPE STRING,
BUSINESS_PARAMS TYPE STRING,
SEM_OBJ TYPE STRING,
SEM_OBJ_ACTION TYPE STRING,
FF_DESKTOP TYPE STRING,
FF_TABLET TYPE STRING,
FF_PHONE TYPE STRING,
MAPPING_SIGNATURE TYPE STRING,
SUB_TITLE TYPE STRING,
SUB_TITLE_TEXT_ID TYPE STRING,
INFORMATION TYPE STRING,
INFO_TEXT_ID TYPE STRING,
CONFIG TYPE STRING,
AGR_NAME TYPE STRING,
AGR_TITLE TYPE STRING,
AGR_ASSIGNED TYPE STRING,
OBJ_NAME TYPE STRING,
OBJ_NAME_ADAPT TYPE STRING,
SWC TYPE STRING,
SERVICE_URL TYPE STRING,
INTERVAL TYPE STRING,
MSG TYPE STRING,
TEST_ID TYPE STRING,
TEXT_ID TYPE STRING,
OBJECT TYPE STRING,
KEYWORDS_TEXT_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_/UI2/FLC_OUTPUT_STRUC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-ICON sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-OBJTYPE sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-DEVCLASS sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-SCOPE sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-CATALOG_ID sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-CATALOG_TITLE sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-CATALOG_TITLE_TEXT_ID sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-GROUP_ID sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-GROUP_TITLE sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-GROUP_TITLE_TEXT_ID sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-SYSTEM_ALIAS sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-CHIP_TITLE sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-CHIP_ID sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-CHIP_ICON sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-CHIP_PARAMETER sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-KEYWORDS sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-CATALOG_REFERENCE_ID sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-TILE_REFERENCE_ID sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-TARGET_MAPPING_REFERENCE_ID sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-TARGET_MAPPING_INFORMATION sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-SAPUI5_TEXT sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-LPD_ROLE sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-LPD_INSTANCE sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-APP_TYPE sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-APPLICATION sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-LPD_GUID sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-LPD_ALIAS sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-LPD_ADD_INFO sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-LPD_TEXT_KEY sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-BUSINESS_PARAMS sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-SEM_OBJ sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-SEM_OBJ_ACTION sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-FF_DESKTOP sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-FF_TABLET sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-FF_PHONE sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-MAPPING_SIGNATURE sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-SUB_TITLE sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-SUB_TITLE_TEXT_ID sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-INFORMATION sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-INFO_TEXT_ID sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-CONFIG sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-AGR_NAME sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-AGR_TITLE sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-AGR_ASSIGNED sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-OBJ_NAME sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-OBJ_NAME_ADAPT sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-SWC sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-SERVICE_URL sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-INTERVAL sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-MSG sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-TEST_ID sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-TEXT_ID sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-OBJECT sy-vline
WA_/UI2/FLC_OUTPUT_STRUC_STR-KEYWORDS_TEXT_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.