ABAP Select data from SAP table /SPE/CRMT_INSP_CONF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SPE/CRMT_INSP_CONF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SPE/CRMT_INSP_CONF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SPE/CRMT_INSP_CONF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SPE/CRMT_INSP_CONF TYPE STANDARD TABLE OF /SPE/CRMT_INSP_CONF,
      WA_/SPE/CRMT_INSP_CONF TYPE /SPE/CRMT_INSP_CONF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SPE/CRMT_INSP_CONF> TYPE /SPE/CRMT_INSP_CONF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SPE/CRMT_INSP_CONF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SPE/CRMT_INSP_CONF
  INTO TABLE IT_/SPE/CRMT_INSP_CONF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SPE/CRMT_INSP_CONF
*  INTO TABLE @DATA(IT_/SPE/CRMT_INSP_CONF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SPE/CRMT_INSP_CONF INDEX 1 INTO DATA(WA_/SPE/CRMT_INSP_CONF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SPE/CRMT_INSP_CONF ASSIGNING </SPE/CRMT_INSP_CONF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SPE/CRMT_INSP_CONF>-RET_AUTH_NUMBER = 1.
</SPE/CRMT_INSP_CONF>-REF_KIND = 1.
</SPE/CRMT_INSP_CONF>-DELIV_NUMB = 1.
</SPE/CRMT_INSP_CONF>-DELIV_ITEM = 1.
</SPE/CRMT_INSP_CONF>-REFLOGSYST = 1.
ENDLOOP.

LOOP AT IT_/SPE/CRMT_INSP_CONF INTO WA_/SPE/CRMT_INSP_CONF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SPE/CRMT_INSP_CONF-PLANT, sy-vline,
WA_/SPE/CRMT_INSP_CONF-INSPECTOR, sy-vline,
WA_/SPE/CRMT_INSP_CONF-CREATED_ON, sy-vline,
WA_/SPE/CRMT_INSP_CONF-TZONE, sy-vline,
WA_/SPE/CRMT_INSP_CONF-INSPEC_NO, sy-vline,
WA_/SPE/CRMT_INSP_CONF-ITEM_NO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SPE/CRMT_INSP_CONF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SPE/CRMT_INSP_CONF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SPE/CRMT_INSP_CONF INTO WA_/SPE/CRMT_INSP_CONF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RET_AUTH_NUMBER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SPE/CRMT_INSP_CONF-RET_AUTH_NUMBER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SPE/CRMT_INSP_CONF-RET_AUTH_NUMBER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DELIV_NUMB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SPE/CRMT_INSP_CONF-DELIV_NUMB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SPE/CRMT_INSP_CONF-DELIV_NUMB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REFLOGSYST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SPE/CRMT_INSP_CONF-REFLOGSYST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SPE/CRMT_INSP_CONF-REFLOGSYST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SPE/CRMT_INSP_CONF-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SPE/CRMT_INSP_CONF-UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SPE/CRMT_INSP_CONF_STR,
RET_AUTH_NUMBER TYPE STRING,
REF_KIND TYPE STRING,
DELIV_NUMB TYPE STRING,
DELIV_ITEM TYPE STRING,
REFLOGSYST TYPE STRING,
PLANT TYPE STRING,
INSPECTOR TYPE STRING,
CREATED_ON TYPE STRING,
TZONE TYPE STRING,
INSPEC_NO TYPE STRING,
ITEM_NO TYPE STRING,
MATERIAL_ACT TYPE STRING,
QUANTITY TYPE STRING,
UNIT TYPE STRING,
CATALOG_R3 TYPE STRING,
CODEGROUP TYPE STRING,
CODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SPE/CRMT_INSP_CONF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-RET_AUTH_NUMBER sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-REF_KIND sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-DELIV_NUMB sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-DELIV_ITEM sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-REFLOGSYST sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-PLANT sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-INSPECTOR sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-CREATED_ON sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-TZONE sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-INSPEC_NO sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-ITEM_NO sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-MATERIAL_ACT sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-QUANTITY sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-UNIT sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-CATALOG_R3 sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-CODEGROUP sy-vline
WA_/SPE/CRMT_INSP_CONF_STR-CODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.