ABAP Select data from SAP table /SCWM/S_WB_BM_ITEM_ROOT_OUT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_WB_BM_ITEM_ROOT_OUT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_WB_BM_ITEM_ROOT_OUT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_WB_BM_ITEM_ROOT_OUT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_WB_BM_ITEM_ROOT_OUT TYPE STANDARD TABLE OF /SCWM/S_WB_BM_ITEM_ROOT_OUT,
      WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT TYPE /SCWM/S_WB_BM_ITEM_ROOT_OUT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_WB_BM_ITEM_ROOT_OUT> TYPE /SCWM/S_WB_BM_ITEM_ROOT_OUT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_WB_BM_ITEM_ROOT_OUT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_WB_BM_ITEM_ROOT_OUT
  INTO TABLE IT_/SCWM/S_WB_BM_ITEM_ROOT_OUT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_WB_BM_ITEM_ROOT_OUT
*  INTO TABLE @DATA(IT_/SCWM/S_WB_BM_ITEM_ROOT_OUT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_WB_BM_ITEM_ROOT_OUT INDEX 1 INTO DATA(WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_WB_BM_ITEM_ROOT_OUT ASSIGNING </SCWM/S_WB_BM_ITEM_ROOT_OUT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_WB_BM_ITEM_ROOT_OUT>-DB_KEY = 1.
</SCWM/S_WB_BM_ITEM_ROOT_OUT>-BM_ID = 1.
</SCWM/S_WB_BM_ITEM_ROOT_OUT>-BM_TYPE = 1.
</SCWM/S_WB_BM_ITEM_ROOT_OUT>-BMR_KEY = 1.
</SCWM/S_WB_BM_ITEM_ROOT_OUT>-BMR_ID = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_WB_BM_ITEM_ROOT_OUT INTO WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-BMR_ROLE, sy-vline,
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-BMR_TYPE, sy-vline,
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-BMRS_KEY, sy-vline,
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-LOCATION_ID, sy-vline,
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-BMRS_ID, sy-vline,
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-BMRS_REF_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_WB_BM_ITEM_ROOT_OUT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_WB_BM_ITEM_ROOT_OUT INTO WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTLC, internal->external for field PLANNED_START_DATETIME CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-PLANNED_START_DATETIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-PLANNED_START_DATETIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field PLANNED_END_DATETIME CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-PLANNED_END_DATETIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-PLANNED_END_DATETIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field ACTUAL_START_DATETIME CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-ACTUAL_START_DATETIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-ACTUAL_START_DATETIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field ACTUAL_END_DATETIME CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-ACTUAL_END_DATETIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-ACTUAL_END_DATETIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field AGGREGATED_DATETIME CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-AGGREGATED_DATETIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-AGGREGATED_DATETIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field DISTRIBUTED_DATETIME CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-DISTRIBUTED_DATETIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-DISTRIBUTED_DATETIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CREATED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-CREATED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-CREATED_ON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field CHANGED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-CHANGED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-CHANGED_ON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT-UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR,
DB_KEY TYPE STRING,
BM_ID TYPE STRING,
BM_TYPE TYPE STRING,
BMR_KEY TYPE STRING,
BMR_ID TYPE STRING,
BMR_ROLE TYPE STRING,
BMR_TYPE TYPE STRING,
BMRS_KEY TYPE STRING,
LOCATION_ID TYPE STRING,
BMRS_ID TYPE STRING,
BMRS_REF_ID TYPE STRING,
LGNUM TYPE STRING,
COUNTRY_CODE TYPE STRING,
REGION_CODE TYPE STRING,
BUSINESS_PARTNER_ID TYPE STRING,
BUSINESS_PARTNER TYPE STRING,
STATUS TYPE STRING,
PLANNED_START_DATETIME TYPE STRING,
PLANNED_END_DATETIME TYPE STRING,
ACTUAL_START_DATETIME TYPE STRING,
ACTUAL_END_DATETIME TYPE STRING,
AGGREGATED_DATETIME TYPE STRING,
DISTRIBUTED_DATETIME TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_ON TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
EEW_BM_ROOT TYPE STRING,
BMR_REF_ID TYPE STRING,
BMR_REF_NO TYPE STRING,
BMR_REF_VERSION TYPE STRING,
BUS_KEY TYPE STRING,
ITEM_NO TYPE STRING,
BMR_ITEM_KEY TYPE STRING,
EXTERNAL_REF_NUMBER TYPE STRING,
CHARGE_TYPE TYPE STRING,
MEASUREMENT_TYPE TYPE STRING,
BMS TYPE STRING,
VARIANT TYPE STRING,
QUANTITY TYPE STRING,
UOM TYPE STRING,
TABNAME TYPE STRING,
EEW_BM_ITEM TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-DB_KEY sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BM_ID sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BM_TYPE sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BMR_KEY sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BMR_ID sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BMR_ROLE sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BMR_TYPE sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BMRS_KEY sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-LOCATION_ID sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BMRS_ID sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BMRS_REF_ID sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-LGNUM sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-COUNTRY_CODE sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-REGION_CODE sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BUSINESS_PARTNER_ID sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BUSINESS_PARTNER sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-STATUS sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-PLANNED_START_DATETIME sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-PLANNED_END_DATETIME sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-ACTUAL_START_DATETIME sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-ACTUAL_END_DATETIME sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-AGGREGATED_DATETIME sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-DISTRIBUTED_DATETIME sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-CREATED_BY sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-CREATED_ON sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-CHANGED_BY sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-CHANGED_ON sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-EEW_BM_ROOT sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BMR_REF_ID sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BMR_REF_NO sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BMR_REF_VERSION sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BUS_KEY sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-ITEM_NO sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BMR_ITEM_KEY sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-EXTERNAL_REF_NUMBER sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-CHARGE_TYPE sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-MEASUREMENT_TYPE sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-BMS sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-VARIANT sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-QUANTITY sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-UOM sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-TABNAME sy-vline
WA_/SCWM/S_WB_BM_ITEM_ROOT_OUT_STR-EEW_BM_ITEM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.