ABAP Select data from SAP table /SCWM/S_SR_CD_DISPLAY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_SR_CD_DISPLAY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_SR_CD_DISPLAY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_SR_CD_DISPLAY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_SR_CD_DISPLAY TYPE STANDARD TABLE OF /SCWM/S_SR_CD_DISPLAY,
      WA_/SCWM/S_SR_CD_DISPLAY TYPE /SCWM/S_SR_CD_DISPLAY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_SR_CD_DISPLAY> TYPE /SCWM/S_SR_CD_DISPLAY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_SR_CD_DISPLAY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_SR_CD_DISPLAY
  INTO TABLE IT_/SCWM/S_SR_CD_DISPLAY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_SR_CD_DISPLAY
*  INTO TABLE @DATA(IT_/SCWM/S_SR_CD_DISPLAY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_SR_CD_DISPLAY INDEX 1 INTO DATA(WA_/SCWM/S_SR_CD_DISPLAY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_SR_CD_DISPLAY ASSIGNING </SCWM/S_SR_CD_DISPLAY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_SR_CD_DISPLAY>-OBJECTID = 1.
</SCWM/S_SR_CD_DISPLAY>-CHANGENR = 1.
</SCWM/S_SR_CD_DISPLAY>-USERNAME = 1.
</SCWM/S_SR_CD_DISPLAY>-UDATE = 1.
</SCWM/S_SR_CD_DISPLAY>-UTIME = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_SR_CD_DISPLAY INTO WA_/SCWM/S_SR_CD_DISPLAY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_SR_CD_DISPLAY-TCODE, sy-vline,
WA_/SCWM/S_SR_CD_DISPLAY-TABNAME, sy-vline,
WA_/SCWM/S_SR_CD_DISPLAY-TABKEY, sy-vline,
WA_/SCWM/S_SR_CD_DISPLAY-KEYLEN, sy-vline,
WA_/SCWM/S_SR_CD_DISPLAY-CHNGIND, sy-vline,
WA_/SCWM/S_SR_CD_DISPLAY-FNAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_SR_CD_DISPLAY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_SR_CD_DISPLAY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_SR_CD_DISPLAY INTO WA_/SCWM/S_SR_CD_DISPLAY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CHANGENR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_SR_CD_DISPLAY-CHANGENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_SR_CD_DISPLAY-CHANGENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRACHE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/SCWM/S_SR_CD_DISPLAY-SPRACHE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_SR_CD_DISPLAY-SPRACHE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OBJECTCLAS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_SR_CD_DISPLAY-OBJECTCLAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_SR_CD_DISPLAY-OBJECTCLAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPH0, internal->external for field SR_ACT_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_SR_CD_DISPLAY-SR_ACT_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_SR_CD_DISPLAY-SR_ACT_NUM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_SR_CD_DISPLAY_STR,
OBJECTID TYPE STRING,
CHANGENR TYPE STRING,
USERNAME TYPE STRING,
UDATE TYPE STRING,
UTIME TYPE STRING,
TCODE TYPE STRING,
TABNAME TYPE STRING,
TABKEY TYPE STRING,
KEYLEN TYPE STRING,
CHNGIND TYPE STRING,
FNAME TYPE STRING,
FTEXT TYPE STRING,
TEXTART TYPE STRING,
SPRACHE TYPE STRING,
TEXT_CASE TYPE STRING,
OUTLEN TYPE STRING,
F_OLD TYPE STRING,
F_NEW TYPE STRING,
KEYGUID TYPE STRING,
TABKEY254 TYPE STRING,
EXT_KEYLEN TYPE STRING,
KEYGUID_STR TYPE STRING,
VERSION TYPE STRING,
OBJECTCLAS TYPE STRING,
TU_NUM_EXT TYPE STRING,
VEH_NUM_EXT TYPE STRING,
SR_ACT_NUM TYPE STRING,
CHTXT TYPE STRING,
NAME_FIRST TYPE STRING,
NAME_LAST TYPE STRING,
DEPARTMENT TYPE STRING,
KEY_TEXT TYPE STRING,
TAB_TEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_SR_CD_DISPLAY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-OBJECTID sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-CHANGENR sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-USERNAME sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-UDATE sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-UTIME sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-TCODE sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-TABNAME sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-TABKEY sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-KEYLEN sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-CHNGIND sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-FNAME sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-FTEXT sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-TEXTART sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-SPRACHE sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-TEXT_CASE sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-OUTLEN sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-F_OLD sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-F_NEW sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-KEYGUID sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-TABKEY254 sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-EXT_KEYLEN sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-KEYGUID_STR sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-VERSION sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-OBJECTCLAS sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-TU_NUM_EXT sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-VEH_NUM_EXT sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-SR_ACT_NUM sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-CHTXT sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-NAME_FIRST sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-NAME_LAST sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-DEPARTMENT sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-KEY_TEXT sy-vline
WA_/SCWM/S_SR_CD_DISPLAY_STR-TAB_TEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.