ABAP Select data from SAP table /SCWM/S_SCO_BCV_SC_CARR_OUT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_SCO_BCV_SC_CARR_OUT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_SCO_BCV_SC_CARR_OUT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_SCO_BCV_SC_CARR_OUT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_SCO_BCV_SC_CARR_OUT TYPE STANDARD TABLE OF /SCWM/S_SCO_BCV_SC_CARR_OUT,
      WA_/SCWM/S_SCO_BCV_SC_CARR_OUT TYPE /SCWM/S_SCO_BCV_SC_CARR_OUT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_SCO_BCV_SC_CARR_OUT> TYPE /SCWM/S_SCO_BCV_SC_CARR_OUT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_SCO_BCV_SC_CARR_OUT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_SCO_BCV_SC_CARR_OUT
  INTO TABLE IT_/SCWM/S_SCO_BCV_SC_CARR_OUT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_SCO_BCV_SC_CARR_OUT
*  INTO TABLE @DATA(IT_/SCWM/S_SCO_BCV_SC_CARR_OUT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_SCO_BCV_SC_CARR_OUT INDEX 1 INTO DATA(WA_/SCWM/S_SCO_BCV_SC_CARR_OUT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_SCO_BCV_SC_CARR_OUT ASSIGNING </SCWM/S_SCO_BCV_SC_CARR_OUT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_SCO_BCV_SC_CARR_OUT>-LGNUM = 1.
</SCWM/S_SCO_BCV_SC_CARR_OUT>-ROUTE_ID = 1.
</SCWM/S_SCO_BCV_SC_CARR_OUT>-CARRIER = 1.
</SCWM/S_SCO_BCV_SC_CARR_OUT>-CARRIER_TEXT = 1.
</SCWM/S_SCO_BCV_SC_CARR_OUT>-SCAC = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_SCO_BCV_SC_CARR_OUT INTO WA_/SCWM/S_SCO_BCV_SC_CARR_OUT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_SCO_BCV_SC_CARR_OUT-NUMBER_OF_PRDO_HDR, sy-vline,
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT-DATE, sy-vline,
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT-TIME, sy-vline,
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT-COUNTRY, sy-vline,
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT-REGION, sy-vline,
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT-POST_CODE1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_SCO_BCV_SC_CARR_OUT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_SCO_BCV_SC_CARR_OUT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_SCO_BCV_SC_CARR_OUT INTO WA_/SCWM/S_SCO_BCV_SC_CARR_OUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CARRIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_SCO_BCV_SC_CARR_OUT-CARRIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_SCO_BCV_SC_CARR_OUT-CARRIER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/SCWM/S_SCO_BCV_SC_CARR_OUT-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_SCO_BCV_SC_CARR_OUT-LANGU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU_CORR CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_/SCWM/S_SCO_BCV_SC_CARR_OUT-LANGU_CORR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_SCO_BCV_SC_CARR_OUT-LANGU_CORR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR,
LGNUM TYPE STRING,
ROUTE_ID TYPE STRING,
CARRIER TYPE STRING,
CARRIER_TEXT TYPE STRING,
SCAC TYPE STRING,
NUMBER_OF_PRDO_HDR TYPE STRING,
DATE TYPE STRING,
TIME TYPE STRING,
COUNTRY TYPE STRING,
REGION TYPE STRING,
POST_CODE1 TYPE STRING,
CITY1 TYPE STRING,
STREET TYPE STRING,
HOUSE_NUM1 TYPE STRING,
TITLE TYPE STRING,
NAME1 TYPE STRING,
NAME2 TYPE STRING,
NAME3 TYPE STRING,
NAME4 TYPE STRING,
LANGU TYPE STRING,
LANGU_CORR TYPE STRING,
TEL_NUMBER TYPE STRING,
TEL_EXTENS TYPE STRING,
TELNR_LONG TYPE STRING,
TELNR_CALL TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-LGNUM sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-ROUTE_ID sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-CARRIER sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-CARRIER_TEXT sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-SCAC sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-NUMBER_OF_PRDO_HDR sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-DATE sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-TIME sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-COUNTRY sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-REGION sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-POST_CODE1 sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-CITY1 sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-STREET sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-HOUSE_NUM1 sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-TITLE sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-NAME1 sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-NAME2 sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-NAME3 sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-NAME4 sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-LANGU sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-LANGU_CORR sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-TEL_NUMBER sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-TEL_EXTENS sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-TELNR_LONG sy-vline
WA_/SCWM/S_SCO_BCV_SC_CARR_OUT_STR-TELNR_CALL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.