ABAP Select data from SAP table /SCWM/S_PAK_MC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_PAK_MC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_PAK_MC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_PAK_MC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_PAK_MC TYPE STANDARD TABLE OF /SCWM/S_PAK_MC,
      WA_/SCWM/S_PAK_MC TYPE /SCWM/S_PAK_MC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_PAK_MC> TYPE /SCWM/S_PAK_MC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_PAK_MC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_PAK_MC
  INTO TABLE IT_/SCWM/S_PAK_MC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_PAK_MC
*  INTO TABLE @DATA(IT_/SCWM/S_PAK_MC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_PAK_MC INDEX 1 INTO DATA(WA_/SCWM/S_PAK_MC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_PAK_MC ASSIGNING </SCWM/S_PAK_MC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_PAK_MC>-KVEWE = 1.
</SCWM/S_PAK_MC>-KOTABNR = 1.
</SCWM/S_PAK_MC>-VARNUMH = 1.
</SCWM/S_PAK_MC>-KSCHL = 1.
</SCWM/S_PAK_MC>-OBJECT_ID = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_PAK_MC INTO WA_/SCWM/S_PAK_MC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_PAK_MC-TIMESTAMP_TO, sy-vline,
WA_/SCWM/S_PAK_MC-RELEASE_STATUS, sy-vline,
WA_/SCWM/S_PAK_MC-TIMESTAMP_FROM, sy-vline,
WA_/SCWM/S_PAK_MC-KSCHL_SUPP, sy-vline,
WA_/SCWM/S_PAK_MC-COND_GROUP_ID, sy-vline,
WA_/SCWM/S_PAK_MC-MAINT_STATUS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_PAK_MC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_PAK_MC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_PAK_MC INTO WA_/SCWM/S_PAK_MC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PAK_CARRIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_PAK_MC-PAK_CARRIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PAK_MC-PAK_CARRIER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MDSCU, internal->external for field PAK_LOCID CALL FUNCTION 'CONVERSION_EXIT_MDSCU_OUTPUT' EXPORTING input = WA_/SCWM/S_PAK_MC-PAK_LOCID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PAK_MC-PAK_LOCID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MDLPD, internal->external for field PAK_MATID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_PAK_MC-PAK_MATID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PAK_MC-PAK_MATID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PAK_PSA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_PAK_MC-PAK_PSA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PAK_MC-PAK_PSA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MDLPD, internal->external for field PAK_REFMATID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_PAK_MC-PAK_REFMATID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PAK_MC-PAK_REFMATID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field PAK_SHIP_FROM CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_PAK_MC-PAK_SHIP_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PAK_MC-PAK_SHIP_FROM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field PAK_SHIP_TO CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_PAK_MC-PAK_SHIP_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PAK_MC-PAK_SHIP_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field PAK_SOLD_TO CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_PAK_MC-PAK_SOLD_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PAK_MC-PAK_SOLD_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PS_PSID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_PAK_MC-PS_PSID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PAK_MC-PS_PSID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PSID, internal->external for field PS_GUID CALL FUNCTION 'CONVERSION_EXIT_PSID_OUTPUT' EXPORTING input = WA_/SCWM/S_PAK_MC-PS_GUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PAK_MC-PS_GUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PAK_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_PAK_MC-PAK_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PAK_MC-PAK_MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PAK_REFMATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_PAK_MC-PAK_REFMATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_PAK_MC-PAK_REFMATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_PAK_MC_STR,
KVEWE TYPE STRING,
KOTABNR TYPE STRING,
VARNUMH TYPE STRING,
KSCHL TYPE STRING,
OBJECT_ID TYPE STRING,
TIMESTAMP_TO TYPE STRING,
RELEASE_STATUS TYPE STRING,
TIMESTAMP_FROM TYPE STRING,
KSCHL_SUPP TYPE STRING,
COND_GROUP_ID TYPE STRING,
MAINT_STATUS TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_ON TYPE STRING,
DET_DEFAULT_TIMESTAMP TYPE STRING,
PAK_AUART TYPE STRING,
PAK_AUGRU TYPE STRING,
PAK_BZIRK TYPE STRING,
PAK_CAP TYPE STRING,
PAK_CARRIER TYPE STRING,
PAK_CNTRY TYPE STRING,
PAK_DEPL_APPL TYPE STRING,
PAK_DEPL_MODE TYPE STRING,
PAK_DEPL_VCL TYPE STRING,
PAK_DIST_GROUP TYPE STRING,
PAK_HUTYP_DFLT TYPE STRING,
PAK_KDGRP TYPE STRING,
PAK_LGTYP TYPE STRING,
PAK_LOCID TYPE STRING,
PAK_MATID TYPE STRING,
PAK_PLANT TYPE STRING,
PAK_PROCTY TYPE STRING,
PAK_PSA TYPE STRING,
PAK_REFMATID TYPE STRING,
PAK_REGIO TYPE STRING,
PAK_ROUTE TYPE STRING,
PAK_RULE TYPE STRING,
PAK_SHIP_FROM TYPE STRING,
PAK_SHIP_TO TYPE STRING,
PAK_SOLD_TO TYPE STRING,
PAK_VSBED TYPE STRING,
PAK_WORKCENTER TYPE STRING,
PS_PSID TYPE STRING,
PS_GUID TYPE STRING,
PS_SEQ TYPE STRING,
PS_COND TYPE STRING,
PS_DISTR TYPE STRING,
KOPOS TYPE STRING,
SUPP_EXIST TYPE STRING,
SCALE_DIM TYPE STRING,
PAK_MATNR TYPE STRING,
PAK_REFMATNR TYPE STRING,
PAK_LOCNO TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_PAK_MC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_PAK_MC_STR-KVEWE sy-vline
WA_/SCWM/S_PAK_MC_STR-KOTABNR sy-vline
WA_/SCWM/S_PAK_MC_STR-VARNUMH sy-vline
WA_/SCWM/S_PAK_MC_STR-KSCHL sy-vline
WA_/SCWM/S_PAK_MC_STR-OBJECT_ID sy-vline
WA_/SCWM/S_PAK_MC_STR-TIMESTAMP_TO sy-vline
WA_/SCWM/S_PAK_MC_STR-RELEASE_STATUS sy-vline
WA_/SCWM/S_PAK_MC_STR-TIMESTAMP_FROM sy-vline
WA_/SCWM/S_PAK_MC_STR-KSCHL_SUPP sy-vline
WA_/SCWM/S_PAK_MC_STR-COND_GROUP_ID sy-vline
WA_/SCWM/S_PAK_MC_STR-MAINT_STATUS sy-vline
WA_/SCWM/S_PAK_MC_STR-CREATED_BY sy-vline
WA_/SCWM/S_PAK_MC_STR-CREATED_ON sy-vline
WA_/SCWM/S_PAK_MC_STR-DET_DEFAULT_TIMESTAMP sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_AUART sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_AUGRU sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_BZIRK sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_CAP sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_CARRIER sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_CNTRY sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_DEPL_APPL sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_DEPL_MODE sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_DEPL_VCL sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_DIST_GROUP sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_HUTYP_DFLT sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_KDGRP sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_LGTYP sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_LOCID sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_MATID sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_PLANT sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_PROCTY sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_PSA sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_REFMATID sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_REGIO sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_ROUTE sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_RULE sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_SHIP_FROM sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_SHIP_TO sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_SOLD_TO sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_VSBED sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_WORKCENTER sy-vline
WA_/SCWM/S_PAK_MC_STR-PS_PSID sy-vline
WA_/SCWM/S_PAK_MC_STR-PS_GUID sy-vline
WA_/SCWM/S_PAK_MC_STR-PS_SEQ sy-vline
WA_/SCWM/S_PAK_MC_STR-PS_COND sy-vline
WA_/SCWM/S_PAK_MC_STR-PS_DISTR sy-vline
WA_/SCWM/S_PAK_MC_STR-KOPOS sy-vline
WA_/SCWM/S_PAK_MC_STR-SUPP_EXIST sy-vline
WA_/SCWM/S_PAK_MC_STR-SCALE_DIM sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_MATNR sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_REFMATNR sy-vline
WA_/SCWM/S_PAK_MC_STR-PAK_LOCNO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.