ABAP Select data from SAP table /SCWM/S_MASS_STOCK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_MASS_STOCK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_MASS_STOCK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_MASS_STOCK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_MASS_STOCK TYPE STANDARD TABLE OF /SCWM/S_MASS_STOCK,
      WA_/SCWM/S_MASS_STOCK TYPE /SCWM/S_MASS_STOCK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_MASS_STOCK> TYPE /SCWM/S_MASS_STOCK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_MASS_STOCK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_MASS_STOCK
  INTO TABLE IT_/SCWM/S_MASS_STOCK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_MASS_STOCK
*  INTO TABLE @DATA(IT_/SCWM/S_MASS_STOCK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_MASS_STOCK INDEX 1 INTO DATA(WA_/SCWM/S_MASS_STOCK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_MASS_STOCK ASSIGNING </SCWM/S_MASS_STOCK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_MASS_STOCK>-PC_ALL = 1.
</SCWM/S_MASS_STOCK>-LGNUM = 1.
</SCWM/S_MASS_STOCK>-POST_QUAN = 1.
</SCWM/S_MASS_STOCK>-ALTME = 1.
</SCWM/S_MASS_STOCK>-PROCTY = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_MASS_STOCK INTO WA_/SCWM/S_MASS_STOCK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_MASS_STOCK-TO_MATNR, sy-vline,
WA_/SCWM/S_MASS_STOCK-TO_HU, sy-vline,
WA_/SCWM/S_MASS_STOCK-TO_CHARG, sy-vline,
WA_/SCWM/S_MASS_STOCK-TO_CAT, sy-vline,
WA_/SCWM/S_MASS_STOCK-TO_OWNER, sy-vline,
WA_/SCWM/S_MASS_STOCK-TO_ENTITLED, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_MASS_STOCK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_MASS_STOCK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_MASS_STOCK INTO WA_/SCWM/S_MASS_STOCK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field ALTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_MASS_STOCK-ALTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MASS_STOCK-ALTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field TO_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_MASS_STOCK-TO_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MASS_STOCK-TO_MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field TO_HU CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_MASS_STOCK-TO_HU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MASS_STOCK-TO_HU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field TO_OWNER CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_MASS_STOCK-TO_OWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MASS_STOCK-TO_OWNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TO_ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_MASS_STOCK-TO_ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MASS_STOCK-TO_ENTITLED.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPH0, internal->external for field WAVE CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_MASS_STOCK-WAVE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_MASS_STOCK-WAVE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_MASS_STOCK_STR,
PC_ALL TYPE STRING,
LGNUM TYPE STRING,
POST_QUAN TYPE STRING,
ALTME TYPE STRING,
PROCTY TYPE STRING,
TO_MATNR TYPE STRING,
TO_HU TYPE STRING,
TO_CHARG TYPE STRING,
TO_CAT TYPE STRING,
TO_OWNER TYPE STRING,
TO_ENTITLED TYPE STRING,
TO_STOCK_DOCCAT TYPE STRING,
TO_STOCK_DOCNO_EXT TYPE STRING,
TO_STOCK_ITMNO TYPE STRING,
TO_STOCK_USAGE TYPE STRING,
NLTYPG TYPE STRING,
NLTYP TYPE STRING,
NLBER TYPE STRING,
NLPLA TYPE STRING,
REASON TYPE STRING,
WAVE TYPE STRING,
PCT_DATUM TYPE STRING,
PCT_UZEIT TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_MASS_STOCK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_MASS_STOCK_STR-PC_ALL sy-vline
WA_/SCWM/S_MASS_STOCK_STR-LGNUM sy-vline
WA_/SCWM/S_MASS_STOCK_STR-POST_QUAN sy-vline
WA_/SCWM/S_MASS_STOCK_STR-ALTME sy-vline
WA_/SCWM/S_MASS_STOCK_STR-PROCTY sy-vline
WA_/SCWM/S_MASS_STOCK_STR-TO_MATNR sy-vline
WA_/SCWM/S_MASS_STOCK_STR-TO_HU sy-vline
WA_/SCWM/S_MASS_STOCK_STR-TO_CHARG sy-vline
WA_/SCWM/S_MASS_STOCK_STR-TO_CAT sy-vline
WA_/SCWM/S_MASS_STOCK_STR-TO_OWNER sy-vline
WA_/SCWM/S_MASS_STOCK_STR-TO_ENTITLED sy-vline
WA_/SCWM/S_MASS_STOCK_STR-TO_STOCK_DOCCAT sy-vline
WA_/SCWM/S_MASS_STOCK_STR-TO_STOCK_DOCNO_EXT sy-vline
WA_/SCWM/S_MASS_STOCK_STR-TO_STOCK_ITMNO sy-vline
WA_/SCWM/S_MASS_STOCK_STR-TO_STOCK_USAGE sy-vline
WA_/SCWM/S_MASS_STOCK_STR-NLTYPG sy-vline
WA_/SCWM/S_MASS_STOCK_STR-NLTYP sy-vline
WA_/SCWM/S_MASS_STOCK_STR-NLBER sy-vline
WA_/SCWM/S_MASS_STOCK_STR-NLPLA sy-vline
WA_/SCWM/S_MASS_STOCK_STR-REASON sy-vline
WA_/SCWM/S_MASS_STOCK_STR-WAVE sy-vline
WA_/SCWM/S_MASS_STOCK_STR-PCT_DATUM sy-vline
WA_/SCWM/S_MASS_STOCK_STR-PCT_UZEIT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.