ABAP Select data from SAP table /SCWM/S_EGF_DEMO_AQTY_POI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_EGF_DEMO_AQTY_POI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_EGF_DEMO_AQTY_POI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_EGF_DEMO_AQTY_POI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_EGF_DEMO_AQTY_POI TYPE STANDARD TABLE OF /SCWM/S_EGF_DEMO_AQTY_POI,
      WA_/SCWM/S_EGF_DEMO_AQTY_POI TYPE /SCWM/S_EGF_DEMO_AQTY_POI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_EGF_DEMO_AQTY_POI> TYPE /SCWM/S_EGF_DEMO_AQTY_POI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_EGF_DEMO_AQTY_POI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_EGF_DEMO_AQTY_POI
  INTO TABLE IT_/SCWM/S_EGF_DEMO_AQTY_POI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_EGF_DEMO_AQTY_POI
*  INTO TABLE @DATA(IT_/SCWM/S_EGF_DEMO_AQTY_POI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_EGF_DEMO_AQTY_POI INDEX 1 INTO DATA(WA_/SCWM/S_EGF_DEMO_AQTY_POI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_EGF_DEMO_AQTY_POI ASSIGNING </SCWM/S_EGF_DEMO_AQTY_POI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_EGF_DEMO_AQTY_POI>-LGNUM = 1.
</SCWM/S_EGF_DEMO_AQTY_POI>-REFDOCNO_PO_I = 1.
</SCWM/S_EGF_DEMO_AQTY_POI>-REFITEMNO_PO_I = 1.
</SCWM/S_EGF_DEMO_AQTY_POI>-SERIE_ID = 1.
</SCWM/S_EGF_DEMO_AQTY_POI>-UI_DLV_QTY_PRDI = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_EGF_DEMO_AQTY_POI INTO WA_/SCWM/S_EGF_DEMO_AQTY_POI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_EGF_DEMO_AQTY_POI-UI_DLV_QTY_PRDO, sy-vline,
WA_/SCWM/S_EGF_DEMO_AQTY_POI-BASE_UOM, sy-vline,
WA_/SCWM/S_EGF_DEMO_AQTY_POI-QTY_TOLERANCE_EXCEEDED, sy-vline,
WA_/SCWM/S_EGF_DEMO_AQTY_POI-NUMBER_OF_PRDI_ITEMS, sy-vline,
WA_/SCWM/S_EGF_DEMO_AQTY_POI-NUMBER_OF_PRDO_ITEMS, sy-vline,
WA_/SCWM/S_EGF_DEMO_AQTY_POI-PRODUCTNO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_EGF_DEMO_AQTY_POI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_EGF_DEMO_AQTY_POI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_EGF_DEMO_AQTY_POI INTO WA_/SCWM/S_EGF_DEMO_AQTY_POI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field REFDOCNO_PO_I CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_EGF_DEMO_AQTY_POI-REFDOCNO_PO_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EGF_DEMO_AQTY_POI-REFDOCNO_PO_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPH0, internal->external for field REFITEMNO_PO_I CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_EGF_DEMO_AQTY_POI-REFITEMNO_PO_I IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EGF_DEMO_AQTY_POI-REFITEMNO_PO_I.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASE_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_EGF_DEMO_AQTY_POI-BASE_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EGF_DEMO_AQTY_POI-BASE_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PRODUCTNO CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_EGF_DEMO_AQTY_POI-PRODUCTNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EGF_DEMO_AQTY_POI-PRODUCTNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_EGF_DEMO_AQTY_POI-ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EGF_DEMO_AQTY_POI-ENTITLED.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field VENDOR CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_EGF_DEMO_AQTY_POI-VENDOR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_EGF_DEMO_AQTY_POI-VENDOR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_EGF_DEMO_AQTY_POI_STR,
LGNUM TYPE STRING,
REFDOCNO_PO_I TYPE STRING,
REFITEMNO_PO_I TYPE STRING,
SERIE_ID TYPE STRING,
UI_DLV_QTY_PRDI TYPE STRING,
UI_DLV_QTY_PRDO TYPE STRING,
BASE_UOM TYPE STRING,
QTY_TOLERANCE_EXCEEDED TYPE STRING,
NUMBER_OF_PRDI_ITEMS TYPE STRING,
NUMBER_OF_PRDO_ITEMS TYPE STRING,
PRODUCTNO TYPE STRING,
PRODUCTNO_TEXT TYPE STRING,
MEDI_PROC TYPE STRING,
MEDI_PROC_TEXT TYPE STRING,
MEDI_APROF TYPE STRING,
MEDI_APROF_TEXT TYPE STRING,
MEDI_AMETH TYPE STRING,
MEDI_AMETH_TEXT TYPE STRING,
MEDI_QUANCLA TYPE STRING,
MEDI_QUANCLA_TEXT TYPE STRING,
ENTITLED TYPE STRING,
ENTITLED_TEXT TYPE STRING,
VENDOR TYPE STRING,
VENDOR_TEXT TYPE STRING,
REFBSKEY_PO_I TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-LGNUM sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-REFDOCNO_PO_I sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-REFITEMNO_PO_I sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-SERIE_ID sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-UI_DLV_QTY_PRDI sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-UI_DLV_QTY_PRDO sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-BASE_UOM sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-QTY_TOLERANCE_EXCEEDED sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-NUMBER_OF_PRDI_ITEMS sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-NUMBER_OF_PRDO_ITEMS sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-PRODUCTNO sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-PRODUCTNO_TEXT sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-MEDI_PROC sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-MEDI_PROC_TEXT sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-MEDI_APROF sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-MEDI_APROF_TEXT sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-MEDI_AMETH sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-MEDI_AMETH_TEXT sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-MEDI_QUANCLA sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-MEDI_QUANCLA_TEXT sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-ENTITLED sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-ENTITLED_TEXT sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-VENDOR sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-VENDOR_TEXT sy-vline
WA_/SCWM/S_EGF_DEMO_AQTY_POI_STR-REFBSKEY_PO_I sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.