ABAP Select data from SAP table /SCWM/S_BUF_EPD_TRANSFER into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_BUF_EPD_TRANSFER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_BUF_EPD_TRANSFER. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_BUF_EPD_TRANSFER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_BUF_EPD_TRANSFER TYPE STANDARD TABLE OF /SCWM/S_BUF_EPD_TRANSFER,
      WA_/SCWM/S_BUF_EPD_TRANSFER TYPE /SCWM/S_BUF_EPD_TRANSFER,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_BUF_EPD_TRANSFER> TYPE /SCWM/S_BUF_EPD_TRANSFER.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_BUF_EPD_TRANSFER.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_BUF_EPD_TRANSFER
  INTO TABLE IT_/SCWM/S_BUF_EPD_TRANSFER.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_BUF_EPD_TRANSFER
*  INTO TABLE @DATA(IT_/SCWM/S_BUF_EPD_TRANSFER2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_BUF_EPD_TRANSFER INDEX 1 INTO DATA(WA_/SCWM/S_BUF_EPD_TRANSFER2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_BUF_EPD_TRANSFER ASSIGNING </SCWM/S_BUF_EPD_TRANSFER>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_BUF_EPD_TRANSFER>-EPD_GUID = 1.
</SCWM/S_BUF_EPD_TRANSFER>-TRSTAT = 1.
</SCWM/S_BUF_EPD_TRANSFER>-EPD_NO = 1.
</SCWM/S_BUF_EPD_TRANSFER>-HR_BSKEY = 1.
</SCWM/S_BUF_EPD_TRANSFER>-LOGSYS = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_BUF_EPD_TRANSFER INTO WA_/SCWM/S_BUF_EPD_TRANSFER.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_BUF_EPD_TRANSFER-PERNR, sy-vline,
WA_/SCWM/S_BUF_EPD_TRANSFER-PRR_ID, sy-vline,
WA_/SCWM/S_BUF_EPD_TRANSFER-STATUS_TXT, sy-vline,
WA_/SCWM/S_BUF_EPD_TRANSFER-VALID_DATE, sy-vline,
WA_/SCWM/S_BUF_EPD_TRANSFER-REFNR, sy-vline,
WA_/SCWM/S_BUF_EPD_TRANSFER-ORIGIN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_BUF_EPD_TRANSFER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_BUF_EPD_TRANSFER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_BUF_EPD_TRANSFER INTO WA_/SCWM/S_BUF_EPD_TRANSFER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPH0, internal->external for field EPD_NO CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_BUF_EPD_TRANSFER-EPD_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_BUF_EPD_TRANSFER-EPD_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_BUF_EPD_TRANSFER-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_BUF_EPD_TRANSFER-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRR_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_BUF_EPD_TRANSFER-PRR_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_BUF_EPD_TRANSFER-PRR_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field VALID_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_BUF_EPD_TRANSFER-VALID_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_BUF_EPD_TRANSFER-VALID_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field EWL_BEGTS CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_BUF_EPD_TRANSFER-EWL_BEGTS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_BUF_EPD_TRANSFER-EWL_BEGTS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field EWL_ENDTS CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_BUF_EPD_TRANSFER-EWL_ENDTS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_BUF_EPD_TRANSFER-EWL_ENDTS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CREATED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_BUF_EPD_TRANSFER-CREATED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_BUF_EPD_TRANSFER-CREATED_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CHANGED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_BUF_EPD_TRANSFER-CHANGED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_BUF_EPD_TRANSFER-CHANGED_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field RELEASED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_BUF_EPD_TRANSFER-RELEASED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_BUF_EPD_TRANSFER-RELEASED_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field PASSED_ON_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_BUF_EPD_TRANSFER-PASSED_ON_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_BUF_EPD_TRANSFER-PASSED_ON_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field DELETED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_/SCWM/S_BUF_EPD_TRANSFER-DELETED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_BUF_EPD_TRANSFER-DELETED_AT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_BUF_EPD_TRANSFER_STR,
EPD_GUID TYPE STRING,
TRSTAT TYPE STRING,
EPD_NO TYPE STRING,
HR_BSKEY TYPE STRING,
LOGSYS TYPE STRING,
PERNR TYPE STRING,
PRR_ID TYPE STRING,
STATUS_TXT TYPE STRING,
VALID_DATE TYPE STRING,
REFNR TYPE STRING,
ORIGIN TYPE STRING,
WAGETYPE TYPE STRING,
AMOUNT TYPE STRING,
CURRENCY TYPE STRING,
AMOUNT_ORIG TYPE STRING,
TZONE TYPE STRING,
EWL_BEGDA TYPE STRING,
EWL_BEGTM TYPE STRING,
EWL_ENDDA TYPE STRING,
EWL_ENDTM TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_TIME TYPE STRING,
CREATED_DATE TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_TIME TYPE STRING,
CHANGED_DATE TYPE STRING,
RELEASED_BY TYPE STRING,
RELEASED_TIME TYPE STRING,
RELEASED_DATE TYPE STRING,
PASSED_ON_BY TYPE STRING,
PASSED_ON_TIME TYPE STRING,
PASSED_ON_DATE TYPE STRING,
DELETED_BY TYPE STRING,
DELETED_TIME TYPE STRING,
DELETED_DATE TYPE STRING,
O_EPD TYPE STRING,
STATUS TYPE STRING,
PRR_GUID TYPE STRING,
VALID_AT TYPE STRING,
EWL_BEGTS TYPE STRING,
EWL_ENDTS TYPE STRING,
CREATED_AT TYPE STRING,
CHANGED_AT TYPE STRING,
RELEASED_AT TYPE STRING,
PASSED_ON_AT TYPE STRING,
DELETED_AT TYPE STRING,
AUTH_ERROR TYPE STRING,
LOCK_ERROR TYPE STRING,
CUST_ERROR TYPE STRING,
BAPI_ERROR TYPE STRING,
EPD_ERROR TYPE STRING,
TRANSFERED TYPE STRING,
RFCDEST TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_BUF_EPD_TRANSFER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-EPD_GUID sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-TRSTAT sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-EPD_NO sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-HR_BSKEY sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-LOGSYS sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-PERNR sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-PRR_ID sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-STATUS_TXT sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-VALID_DATE sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-REFNR sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-ORIGIN sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-WAGETYPE sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-AMOUNT sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-CURRENCY sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-AMOUNT_ORIG sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-TZONE sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-EWL_BEGDA sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-EWL_BEGTM sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-EWL_ENDDA sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-EWL_ENDTM sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-CREATED_BY sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-CREATED_TIME sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-CREATED_DATE sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-CHANGED_BY sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-CHANGED_TIME sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-CHANGED_DATE sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-RELEASED_BY sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-RELEASED_TIME sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-RELEASED_DATE sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-PASSED_ON_BY sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-PASSED_ON_TIME sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-PASSED_ON_DATE sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-DELETED_BY sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-DELETED_TIME sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-DELETED_DATE sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-O_EPD sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-STATUS sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-PRR_GUID sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-VALID_AT sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-EWL_BEGTS sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-EWL_ENDTS sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-CREATED_AT sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-CHANGED_AT sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-RELEASED_AT sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-PASSED_ON_AT sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-DELETED_AT sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-AUTH_ERROR sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-LOCK_ERROR sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-CUST_ERROR sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-BAPI_ERROR sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-EPD_ERROR sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-TRANSFERED sy-vline
WA_/SCWM/S_BUF_EPD_TRANSFER_STR-RFCDEST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.