ABAP Select data from SAP table /SCWM/S_ASPQ_YMOVE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_ASPQ_YMOVE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_ASPQ_YMOVE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_ASPQ_YMOVE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_ASPQ_YMOVE TYPE STANDARD TABLE OF /SCWM/S_ASPQ_YMOVE,
      WA_/SCWM/S_ASPQ_YMOVE TYPE /SCWM/S_ASPQ_YMOVE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_ASPQ_YMOVE> TYPE /SCWM/S_ASPQ_YMOVE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_ASPQ_YMOVE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_ASPQ_YMOVE
  INTO TABLE IT_/SCWM/S_ASPQ_YMOVE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_ASPQ_YMOVE
*  INTO TABLE @DATA(IT_/SCWM/S_ASPQ_YMOVE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_ASPQ_YMOVE INDEX 1 INTO DATA(WA_/SCWM/S_ASPQ_YMOVE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_ASPQ_YMOVE ASSIGNING </SCWM/S_ASPQ_YMOVE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_ASPQ_YMOVE>-TU_NUM = 1.
</SCWM/S_ASPQ_YMOVE>-TU_NUM_EXT = 1.
</SCWM/S_ASPQ_YMOVE>-LIC_PLATE = 1.
</SCWM/S_ASPQ_YMOVE>-CHECKPNT = 1.
</SCWM/S_ASPQ_YMOVE>-MTR = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_ASPQ_YMOVE INTO WA_/SCWM/S_ASPQ_YMOVE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_ASPQ_YMOVE-ROUTE_ID, sy-vline,
WA_/SCWM/S_ASPQ_YMOVE-ROUTE_DEP_DATE, sy-vline,
WA_/SCWM/S_ASPQ_YMOVE-ROUTE_DEP_TIME, sy-vline,
WA_/SCWM/S_ASPQ_YMOVE-VEH_NUM, sy-vline,
WA_/SCWM/S_ASPQ_YMOVE-VEH_NUM_EXT, sy-vline,
WA_/SCWM/S_ASPQ_YMOVE-LIC_PLATE_VEH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_ASPQ_YMOVE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_ASPQ_YMOVE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_ASPQ_YMOVE INTO WA_/SCWM/S_ASPQ_YMOVE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field TU_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ASPQ_YMOVE-TU_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASPQ_YMOVE-TU_NUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VEH_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ASPQ_YMOVE-VEH_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASPQ_YMOVE-VEH_NUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TSP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ASPQ_YMOVE-TSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASPQ_YMOVE-TSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field FROM_PARTYNO CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_ASPQ_YMOVE-FROM_PARTYNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASPQ_YMOVE-FROM_PARTYNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field TO_PARTYNO CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_ASPQ_YMOVE-TO_PARTYNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASPQ_YMOVE-TO_PARTYNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_ASPQ_YMOVE-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASPQ_YMOVE-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FRD_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ASPQ_YMOVE-FRD_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASPQ_YMOVE-FRD_NUM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_ASPQ_YMOVE_STR,
TU_NUM TYPE STRING,
TU_NUM_EXT TYPE STRING,
LIC_PLATE TYPE STRING,
CHECKPNT TYPE STRING,
MTR TYPE STRING,
ROUTE_ID TYPE STRING,
ROUTE_DEP_DATE TYPE STRING,
ROUTE_DEP_TIME TYPE STRING,
VEH_NUM TYPE STRING,
VEH_NUM_EXT TYPE STRING,
LIC_PLATE_VEH TYPE STRING,
DOCNO TYPE STRING,
TSP TYPE STRING,
YLGNUM TYPE STRING,
DOOR TYPE STRING,
VLTYP TYPE STRING,
VLBER TYPE STRING,
VLPLA TYPE STRING,
UNAME TYPE STRING,
PRIO_PTS TYPE STRING,
DLV_DOCTYPE TYPE STRING,
TRART TYPE STRING,
SCAC TYPE STRING,
FROM_PARTYNO TYPE STRING,
TO_PARTYNO TYPE STRING,
REFDOCNO_ASN TYPE STRING,
MATNR TYPE STRING,
FRD_NUM TYPE STRING,
SCU_SO TYPE STRING,
SCU_RO TYPE STRING,
OUT_YARD_DATE TYPE STRING,
OUT_YARD_TIME TYPE STRING,
DLV_FREE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_ASPQ_YMOVE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-TU_NUM sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-TU_NUM_EXT sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-LIC_PLATE sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-CHECKPNT sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-MTR sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-ROUTE_ID sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-ROUTE_DEP_DATE sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-ROUTE_DEP_TIME sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-VEH_NUM sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-VEH_NUM_EXT sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-LIC_PLATE_VEH sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-DOCNO sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-TSP sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-YLGNUM sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-DOOR sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-VLTYP sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-VLBER sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-VLPLA sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-UNAME sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-PRIO_PTS sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-DLV_DOCTYPE sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-TRART sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-SCAC sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-FROM_PARTYNO sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-TO_PARTYNO sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-REFDOCNO_ASN sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-MATNR sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-FRD_NUM sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-SCU_SO sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-SCU_RO sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-OUT_YARD_DATE sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-OUT_YARD_TIME sy-vline
WA_/SCWM/S_ASPQ_YMOVE_STR-DLV_FREE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.