ABAP Select data from SAP table /SCWM/S_ASP_TO_DISP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/S_ASP_TO_DISP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/S_ASP_TO_DISP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/S_ASP_TO_DISP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/S_ASP_TO_DISP TYPE STANDARD TABLE OF /SCWM/S_ASP_TO_DISP,
      WA_/SCWM/S_ASP_TO_DISP TYPE /SCWM/S_ASP_TO_DISP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/S_ASP_TO_DISP> TYPE /SCWM/S_ASP_TO_DISP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/S_ASP_TO_DISP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/S_ASP_TO_DISP
  INTO TABLE IT_/SCWM/S_ASP_TO_DISP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/S_ASP_TO_DISP
*  INTO TABLE @DATA(IT_/SCWM/S_ASP_TO_DISP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/S_ASP_TO_DISP INDEX 1 INTO DATA(WA_/SCWM/S_ASP_TO_DISP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/S_ASP_TO_DISP ASSIGNING </SCWM/S_ASP_TO_DISP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/S_ASP_TO_DISP>-GUID_TO = 1.
</SCWM/S_ASP_TO_DISP>-LGNUM = 1.
</SCWM/S_ASP_TO_DISP>-TANUM = 1.
</SCWM/S_ASP_TO_DISP>-TAPOS = 1.
</SCWM/S_ASP_TO_DISP>-FLGHUTO = 1.
ENDLOOP.

LOOP AT IT_/SCWM/S_ASP_TO_DISP INTO WA_/SCWM/S_ASP_TO_DISP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/S_ASP_TO_DISP-TOSTAT, sy-vline,
WA_/SCWM/S_ASP_TO_DISP-STATUS_TXT, sy-vline,
WA_/SCWM/S_ASP_TO_DISP-ARCHIVEFL, sy-vline,
WA_/SCWM/S_ASP_TO_DISP-PROCTY, sy-vline,
WA_/SCWM/S_ASP_TO_DISP-TRART, sy-vline,
WA_/SCWM/S_ASP_TO_DISP-TRART_TXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/S_ASP_TO_DISP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/S_ASP_TO_DISP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/S_ASP_TO_DISP INTO WA_/SCWM/S_ASP_TO_DISP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPH0, internal->external for field TANUM CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-TANUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-TANUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPH0, internal->external for field TAPOS CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-TAPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-TAPOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MDLPD, internal->external for field MATID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-MATID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-MATID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTWH, internal->external for field CREATED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTWH_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-CREATED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-CREATED_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BPMAP, internal->external for field OWNER CALL FUNCTION 'CONVERSION_EXIT_BPMAP_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-OWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-OWNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-ENTITLED.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ALTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-ALTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-ALTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_W CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-UNIT_W IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-UNIT_W.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_V CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-UNIT_V IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-UNIT_V.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTWH, internal->external for field WDATU CALL FUNCTION 'CONVERSION_EXIT_TSTWH_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-WDATU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-WDATU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INSPDOCNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-INSPDOCNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-INSPDOCNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STU_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-STU_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-STU_NUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSPWM, internal->external for field STSP CALL FUNCTION 'CONVERSION_EXIT_TSPWM_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-STSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-STSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field VLENR CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-VLENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-VLENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DTU_NUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-DTU_NUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-DTU_NUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSPWM, internal->external for field DTSP CALL FUNCTION 'CONVERSION_EXIT_TSPWM_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-DTSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-DTSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit HUID, internal->external for field NLENR CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-NLENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-NLENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZEIEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-ZEIEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-ZEIEI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RDOCNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-RDOCNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-RDOCNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RITEMNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-RITEMNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-RITEMNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QDOCNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-QDOCNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-QDOCNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field QITEMNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-QITEMNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-QITEMNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPH0, internal->external for field WAVE CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-WAVE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-WAVE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPH0, internal->external for field WAVE_ITM CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-WAVE_ITM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-WAVE_ITM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS_EXT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-LOGSYS_EXT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-LOGSYS_EXT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPH0, internal->external for field WHO CALL FUNCTION 'CONVERSION_EXIT_ALPH0_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-WHO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-WHO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTWH, internal->external for field CONFIRMED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTWH_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-CONFIRMED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-CONFIRMED_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PROCR, internal->external for field PROCESSOR CALL FUNCTION 'CONVERSION_EXIT_PROCR_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-PROCESSOR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-PROCESSOR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTWH, internal->external for field STARTED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTWH_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-STARTED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-STARTED_AT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CWUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/S_ASP_TO_DISP-CWUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/S_ASP_TO_DISP-CWUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/S_ASP_TO_DISP_STR,
GUID_TO TYPE STRING,
LGNUM TYPE STRING,
TANUM TYPE STRING,
TAPOS TYPE STRING,
FLGHUTO TYPE STRING,
TOSTAT TYPE STRING,
STATUS_TXT TYPE STRING,
ARCHIVEFL TYPE STRING,
PROCTY TYPE STRING,
TRART TYPE STRING,
TRART_TXT TYPE STRING,
SER_STOCK TYPE STRING,
ACT_TYPE TYPE STRING,
MATID TYPE STRING,
MATNR TYPE STRING,
MAKTX TYPE STRING,
BATCHID TYPE STRING,
CHARG TYPE STRING,
PRCES TYPE STRING,
PROCS TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_AT TYPE STRING,
CREA_DATE TYPE STRING,
CREA_TIME TYPE STRING,
PRSRC TYPE STRING,
REASON TYPE STRING,
SERIAL TYPE STRING,
CAT TYPE STRING,
CAT_TEXT TYPE STRING,
STOCK_DOCCAT TYPE STRING,
STOCK_DOCCAT_TEXT TYPE STRING,
STOCK_DOCNO TYPE STRING,
STOCK_DOCNO_EXT TYPE STRING,
STOCK_ITMNO TYPE STRING,
DOCCAT TYPE STRING,
STOCK_USAGE TYPE STRING,
OWNER TYPE STRING,
ENTITLED TYPE STRING,
MEINS TYPE STRING,
ALTME TYPE STRING,
LETYP TYPE STRING,
WEIGHT TYPE STRING,
UNIT_W TYPE STRING,
VOLUM TYPE STRING,
UNIT_V TYPE STRING,
CAPA TYPE STRING,
PLACE_INV_P TYPE STRING,
PLACE_INV TYPE STRING,
LOWCHK_INV_P TYPE STRING,
LOWCHK_INV TYPE STRING,
VFDAT TYPE STRING,
WDATU TYPE STRING,
WE_DATUM TYPE STRING,
WE_UZEIT TYPE STRING,
COO TYPE STRING,
INSPID TYPE STRING,
INSPTYP TYPE STRING,
INSPDOCNO TYPE STRING,
IDPLATE TYPE STRING,
VLTYP TYPE STRING,
VLBER TYPE STRING,
VLPLA TYPE STRING,
SLOGPOS TYPE STRING,
SRSRC TYPE STRING,
STU_NUM TYPE STRING,
STU_NUM_EXT TYPE STRING,
STSP TYPE STRING,
STSP_TEXT TYPE STRING,
VLENR TYPE STRING,
VANZL TYPE STRING,
VSOLM TYPE STRING,
VSOLA TYPE STRING,
KQUAN TYPE STRING,
NLTYP TYPE STRING,
NLBER TYPE STRING,
NLPLA TYPE STRING,
DLOGPOS TYPE STRING,
DLOGPOS_EXT_WT TYPE STRING,
DRSRC TYPE STRING,
DTU_NUM TYPE STRING,
DTU_NUM_EXT TYPE STRING,
DTSP TYPE STRING,
DTSP_TEXT TYPE STRING,
NLENR TYPE STRING,
NANZL TYPE STRING,
DESTD TYPE STRING,
HOMVE TYPE STRING,
NEGAT TYPE STRING,
KZSUB TYPE STRING,
SOLPO TYPE STRING,
ZEIEI TYPE STRING,
PICK_ALL TYPE STRING,
ROUTETO TYPE STRING,
RDOCCAT TYPE STRING,
RDOCID TYPE STRING,
RITMID TYPE STRING,
RDOCNO TYPE STRING,
RITEMNO TYPE STRING,
QDOCCAT TYPE STRING,
QDOCID TYPE STRING,
QITMID TYPE STRING,
QDOCNO TYPE STRING,
QITEMNO TYPE STRING,
QIDPLATE TYPE STRING,
ROUTE TYPE STRING,
RTEXT TYPE STRING,
WHCOUNT TYPE STRING,
GR_OPEN TYPE STRING,
WAVE TYPE STRING,
WAVE_ITM TYPE STRING,
L2SKA TYPE STRING,
L2SKR TYPE STRING,
STR_REPL TYPE STRING,
DOCCAT_EXT TYPE STRING,
DOCNO_EXT TYPE STRING,
ITMNO_EXT TYPE STRING,
LOGSYS_EXT TYPE STRING,
PICK_COMP_DT TYPE STRING,
PICK_COMP_DATE TYPE STRING,
PICK_COMP_TIME TYPE STRING,
REPID TYPE STRING,
TCODE TYPE STRING,
AAREA TYPE STRING,
AREAWHO TYPE STRING,
WCR TYPE STRING,
PATHSEQ TYPE STRING,
QUEUE TYPE STRING,
DSTGRP TYPE STRING,
WHO TYPE STRING,
CONFIRMED_BY TYPE STRING,
CONFIRMED_AT TYPE STRING,
CONF_DATE TYPE STRING,
CONF_TIME TYPE STRING,
PROCESSOR TYPE STRING,
EXCCODE TYPE STRING,
BUSCON TYPE STRING,
EXEC_STEP TYPE STRING,
DESCR TYPE STRING,
STARTED_AT TYPE STRING,
START_DATE TYPE STRING,
START_TIME TYPE STRING,
NISTM TYPE STRING,
NISTA TYPE STRING,
HUENT TYPE STRING,
DMENG TYPE STRING,
DMENA TYPE STRING,
CWREL TYPE STRING,
NISTA_CWQUAN TYPE STRING,
CWEXACT TYPE STRING,
NDIFA_CWQUAN TYPE STRING,
CWQEXACT_DIFF TYPE STRING,
CWUNIT TYPE STRING,
DBIND TYPE STRING,
FLG_PAS TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/S_ASP_TO_DISP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-GUID_TO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-LGNUM sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-TANUM sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-TAPOS sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-FLGHUTO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-TOSTAT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-STATUS_TXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-ARCHIVEFL sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-PROCTY sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-TRART sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-TRART_TXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-SER_STOCK sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-ACT_TYPE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-MATID sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-MATNR sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-MAKTX sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-BATCHID sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CHARG sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-PRCES sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-PROCS sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CREATED_BY sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CREATED_AT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CREA_DATE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CREA_TIME sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-PRSRC sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-REASON sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-SERIAL sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CAT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CAT_TEXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-STOCK_DOCCAT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-STOCK_DOCCAT_TEXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-STOCK_DOCNO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-STOCK_DOCNO_EXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-STOCK_ITMNO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DOCCAT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-STOCK_USAGE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-OWNER sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-ENTITLED sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-MEINS sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-ALTME sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-LETYP sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-WEIGHT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-UNIT_W sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-VOLUM sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-UNIT_V sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CAPA sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-PLACE_INV_P sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-PLACE_INV sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-LOWCHK_INV_P sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-LOWCHK_INV sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-VFDAT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-WDATU sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-WE_DATUM sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-WE_UZEIT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-COO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-INSPID sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-INSPTYP sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-INSPDOCNO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-IDPLATE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-VLTYP sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-VLBER sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-VLPLA sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-SLOGPOS sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-SRSRC sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-STU_NUM sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-STU_NUM_EXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-STSP sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-STSP_TEXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-VLENR sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-VANZL sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-VSOLM sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-VSOLA sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-KQUAN sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-NLTYP sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-NLBER sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-NLPLA sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DLOGPOS sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DLOGPOS_EXT_WT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DRSRC sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DTU_NUM sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DTU_NUM_EXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DTSP sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DTSP_TEXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-NLENR sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-NANZL sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DESTD sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-HOMVE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-NEGAT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-KZSUB sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-SOLPO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-ZEIEI sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-PICK_ALL sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-ROUTETO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-RDOCCAT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-RDOCID sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-RITMID sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-RDOCNO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-RITEMNO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-QDOCCAT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-QDOCID sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-QITMID sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-QDOCNO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-QITEMNO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-QIDPLATE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-ROUTE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-RTEXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-WHCOUNT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-GR_OPEN sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-WAVE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-WAVE_ITM sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-L2SKA sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-L2SKR sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-STR_REPL sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DOCCAT_EXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DOCNO_EXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-ITMNO_EXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-LOGSYS_EXT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-PICK_COMP_DT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-PICK_COMP_DATE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-PICK_COMP_TIME sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-REPID sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-TCODE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-AAREA sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-AREAWHO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-WCR sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-PATHSEQ sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-QUEUE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DSTGRP sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-WHO sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CONFIRMED_BY sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CONFIRMED_AT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CONF_DATE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CONF_TIME sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-PROCESSOR sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-EXCCODE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-BUSCON sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-EXEC_STEP sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DESCR sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-STARTED_AT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-START_DATE sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-START_TIME sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-NISTM sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-NISTA sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-HUENT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DMENG sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DMENA sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CWREL sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-NISTA_CWQUAN sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CWEXACT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-NDIFA_CWQUAN sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CWQEXACT_DIFF sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-CWUNIT sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-DBIND sy-vline
WA_/SCWM/S_ASP_TO_DISP_STR-FLG_PAS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.