ABAP Select data from SAP table /SCWM/LM_PL_AGG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/LM_PL_AGG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/LM_PL_AGG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/LM_PL_AGG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/LM_PL_AGG TYPE STANDARD TABLE OF /SCWM/LM_PL_AGG,
      WA_/SCWM/LM_PL_AGG TYPE /SCWM/LM_PL_AGG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/LM_PL_AGG> TYPE /SCWM/LM_PL_AGG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/LM_PL_AGG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/LM_PL_AGG
  INTO TABLE IT_/SCWM/LM_PL_AGG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/LM_PL_AGG
*  INTO TABLE @DATA(IT_/SCWM/LM_PL_AGG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/LM_PL_AGG INDEX 1 INTO DATA(WA_/SCWM/LM_PL_AGG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/LM_PL_AGG ASSIGNING </SCWM/LM_PL_AGG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/LM_PL_AGG>-MANDT = 1.
</SCWM/LM_PL_AGG>-LGNUM = 1.
</SCWM/LM_PL_AGG>-SAVE_ID = 1.
</SCWM/LM_PL_AGG>-SAVED_AT = 1.
</SCWM/LM_PL_AGG>-UNAME = 1.
ENDLOOP.

LOOP AT IT_/SCWM/LM_PL_AGG INTO WA_/SCWM/LM_PL_AGG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/LM_PL_AGG-PROCS, sy-vline,
WA_/SCWM/LM_PL_AGG-AAREA, sy-vline,
WA_/SCWM/LM_PL_AGG-SIM_VER, sy-vline,
WA_/SCWM/LM_PL_AGG-NUM_WL, sy-vline,
WA_/SCWM/LM_PL_AGG-PLDURA, sy-vline,
WA_/SCWM/LM_PL_AGG-UNIT_T, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/LM_PL_AGG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/LM_PL_AGG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/LM_PL_AGG INTO WA_/SCWM/LM_PL_AGG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UNIT_T CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/LM_PL_AGG-UNIT_T IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/LM_PL_AGG-UNIT_T.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_W CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/LM_PL_AGG-UNIT_W IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/LM_PL_AGG-UNIT_W.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_V CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/LM_PL_AGG-UNIT_V IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/LM_PL_AGG-UNIT_V.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_D CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/LM_PL_AGG-UNIT_D IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/LM_PL_AGG-UNIT_D.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/LM_PL_AGG_STR,
MANDT TYPE STRING,
LGNUM TYPE STRING,
SAVE_ID TYPE STRING,
SAVED_AT TYPE STRING,
UNAME TYPE STRING,
PROCS TYPE STRING,
AAREA TYPE STRING,
SIM_VER TYPE STRING,
NUM_WL TYPE STRING,
PLDURA TYPE STRING,
UNIT_T TYPE STRING,
WEIGHT TYPE STRING,
UNIT_W TYPE STRING,
VOLUM TYPE STRING,
UNIT_V TYPE STRING,
CAPA TYPE STRING,
DISTANCE TYPE STRING,
DISTANCE_Z TYPE STRING,
DISTANCE_TIME TYPE STRING,
UNIT_D TYPE STRING,
NUM_PR TYPE STRING,
EFF TYPE STRING,
FORMULA TYPE STRING,
PLAN_RESULT TYPE STRING,
FORMULA_SIM TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/LM_PL_AGG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/LM_PL_AGG_STR-MANDT sy-vline
WA_/SCWM/LM_PL_AGG_STR-LGNUM sy-vline
WA_/SCWM/LM_PL_AGG_STR-SAVE_ID sy-vline
WA_/SCWM/LM_PL_AGG_STR-SAVED_AT sy-vline
WA_/SCWM/LM_PL_AGG_STR-UNAME sy-vline
WA_/SCWM/LM_PL_AGG_STR-PROCS sy-vline
WA_/SCWM/LM_PL_AGG_STR-AAREA sy-vline
WA_/SCWM/LM_PL_AGG_STR-SIM_VER sy-vline
WA_/SCWM/LM_PL_AGG_STR-NUM_WL sy-vline
WA_/SCWM/LM_PL_AGG_STR-PLDURA sy-vline
WA_/SCWM/LM_PL_AGG_STR-UNIT_T sy-vline
WA_/SCWM/LM_PL_AGG_STR-WEIGHT sy-vline
WA_/SCWM/LM_PL_AGG_STR-UNIT_W sy-vline
WA_/SCWM/LM_PL_AGG_STR-VOLUM sy-vline
WA_/SCWM/LM_PL_AGG_STR-UNIT_V sy-vline
WA_/SCWM/LM_PL_AGG_STR-CAPA sy-vline
WA_/SCWM/LM_PL_AGG_STR-DISTANCE sy-vline
WA_/SCWM/LM_PL_AGG_STR-DISTANCE_Z sy-vline
WA_/SCWM/LM_PL_AGG_STR-DISTANCE_TIME sy-vline
WA_/SCWM/LM_PL_AGG_STR-UNIT_D sy-vline
WA_/SCWM/LM_PL_AGG_STR-NUM_PR sy-vline
WA_/SCWM/LM_PL_AGG_STR-EFF sy-vline
WA_/SCWM/LM_PL_AGG_STR-FORMULA sy-vline
WA_/SCWM/LM_PL_AGG_STR-PLAN_RESULT sy-vline
WA_/SCWM/LM_PL_AGG_STR-FORMULA_SIM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.