ABAP Select data from SAP table /SCWM/E1LTORI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/E1LTORI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/E1LTORI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/E1LTORI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/E1LTORI TYPE STANDARD TABLE OF /SCWM/E1LTORI,
      WA_/SCWM/E1LTORI TYPE /SCWM/E1LTORI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/E1LTORI> TYPE /SCWM/E1LTORI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/E1LTORI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/E1LTORI
  INTO TABLE IT_/SCWM/E1LTORI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/E1LTORI
*  INTO TABLE @DATA(IT_/SCWM/E1LTORI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/E1LTORI INDEX 1 INTO DATA(WA_/SCWM/E1LTORI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/E1LTORI ASSIGNING </SCWM/E1LTORI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/E1LTORI>-TANUM = 1.
</SCWM/E1LTORI>-PROCTY = 1.
</SCWM/E1LTORI>-MATNR = 1.
</SCWM/E1LTORI>-ENTITLED = 1.
</SCWM/E1LTORI>-ENTITLED_ROLE = 1.
ENDLOOP.

LOOP AT IT_/SCWM/E1LTORI INTO WA_/SCWM/E1LTORI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/E1LTORI-OWNER, sy-vline,
WA_/SCWM/E1LTORI-OWNER_ROLE, sy-vline,
WA_/SCWM/E1LTORI-CHARG, sy-vline,
WA_/SCWM/E1LTORI-LETYP, sy-vline,
WA_/SCWM/E1LTORI-ANFME, sy-vline,
WA_/SCWM/E1LTORI-ALTME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/E1LTORI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/E1LTORI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/E1LTORI INTO WA_/SCWM/E1LTORI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/E1LTORI_STR,
TANUM TYPE STRING,
PROCTY TYPE STRING,
MATNR TYPE STRING,
ENTITLED TYPE STRING,
ENTITLED_ROLE TYPE STRING,
OWNER TYPE STRING,
OWNER_ROLE TYPE STRING,
CHARG TYPE STRING,
LETYP TYPE STRING,
ANFME TYPE STRING,
ALTME TYPE STRING,
OPUNIT TYPE STRING,
VSOLA TYPE STRING,
VSOLM TYPE STRING,
MEINS TYPE STRING,
VLTYP TYPE STRING,
VLBER TYPE STRING,
VLPLA TYPE STRING,
NLTYP TYPE STRING,
NLBER TYPE STRING,
NLPLA TYPE STRING,
VLENR TYPE STRING,
NLENR TYPE STRING,
TRART TYPE STRING,
PROCS TYPE STRING,
PRCES TYPE STRING,
WDATU TYPE STRING,
WDATZ TYPE STRING,
VFDAT TYPE STRING,
ZEUGN TYPE STRING,
KOMPL TYPE STRING,
SQUIT TYPE STRING,
KZQUI TYPE STRING,
MAKTX TYPE STRING,
DOCCAT TYPE STRING,
DOCNO TYPE STRING,
ITEMNO TYPE STRING,
KZNKO TYPE STRING,
CAT TYPE STRING,
STOCK_DOCCAT TYPE STRING,
STOCK_DOCNO TYPE STRING,
STOCK_ITMNO TYPE STRING,
WAVE TYPE STRING,
FLGHUTO TYPE STRING,
PRIORITY TYPE STRING,
PICK_COMP_DATE TYPE STRING,
PICK_COMP_TIME TYPE STRING,
IDPLATE TYPE STRING,
PICK_ALL TYPE STRING,
DSTGRP TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/E1LTORI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/E1LTORI_STR-TANUM sy-vline
WA_/SCWM/E1LTORI_STR-PROCTY sy-vline
WA_/SCWM/E1LTORI_STR-MATNR sy-vline
WA_/SCWM/E1LTORI_STR-ENTITLED sy-vline
WA_/SCWM/E1LTORI_STR-ENTITLED_ROLE sy-vline
WA_/SCWM/E1LTORI_STR-OWNER sy-vline
WA_/SCWM/E1LTORI_STR-OWNER_ROLE sy-vline
WA_/SCWM/E1LTORI_STR-CHARG sy-vline
WA_/SCWM/E1LTORI_STR-LETYP sy-vline
WA_/SCWM/E1LTORI_STR-ANFME sy-vline
WA_/SCWM/E1LTORI_STR-ALTME sy-vline
WA_/SCWM/E1LTORI_STR-OPUNIT sy-vline
WA_/SCWM/E1LTORI_STR-VSOLA sy-vline
WA_/SCWM/E1LTORI_STR-VSOLM sy-vline
WA_/SCWM/E1LTORI_STR-MEINS sy-vline
WA_/SCWM/E1LTORI_STR-VLTYP sy-vline
WA_/SCWM/E1LTORI_STR-VLBER sy-vline
WA_/SCWM/E1LTORI_STR-VLPLA sy-vline
WA_/SCWM/E1LTORI_STR-NLTYP sy-vline
WA_/SCWM/E1LTORI_STR-NLBER sy-vline
WA_/SCWM/E1LTORI_STR-NLPLA sy-vline
WA_/SCWM/E1LTORI_STR-VLENR sy-vline
WA_/SCWM/E1LTORI_STR-NLENR sy-vline
WA_/SCWM/E1LTORI_STR-TRART sy-vline
WA_/SCWM/E1LTORI_STR-PROCS sy-vline
WA_/SCWM/E1LTORI_STR-PRCES sy-vline
WA_/SCWM/E1LTORI_STR-WDATU sy-vline
WA_/SCWM/E1LTORI_STR-WDATZ sy-vline
WA_/SCWM/E1LTORI_STR-VFDAT sy-vline
WA_/SCWM/E1LTORI_STR-ZEUGN sy-vline
WA_/SCWM/E1LTORI_STR-KOMPL sy-vline
WA_/SCWM/E1LTORI_STR-SQUIT sy-vline
WA_/SCWM/E1LTORI_STR-KZQUI sy-vline
WA_/SCWM/E1LTORI_STR-MAKTX sy-vline
WA_/SCWM/E1LTORI_STR-DOCCAT sy-vline
WA_/SCWM/E1LTORI_STR-DOCNO sy-vline
WA_/SCWM/E1LTORI_STR-ITEMNO sy-vline
WA_/SCWM/E1LTORI_STR-KZNKO sy-vline
WA_/SCWM/E1LTORI_STR-CAT sy-vline
WA_/SCWM/E1LTORI_STR-STOCK_DOCCAT sy-vline
WA_/SCWM/E1LTORI_STR-STOCK_DOCNO sy-vline
WA_/SCWM/E1LTORI_STR-STOCK_ITMNO sy-vline
WA_/SCWM/E1LTORI_STR-WAVE sy-vline
WA_/SCWM/E1LTORI_STR-FLGHUTO sy-vline
WA_/SCWM/E1LTORI_STR-PRIORITY sy-vline
WA_/SCWM/E1LTORI_STR-PICK_COMP_DATE sy-vline
WA_/SCWM/E1LTORI_STR-PICK_COMP_TIME sy-vline
WA_/SCWM/E1LTORI_STR-IDPLATE sy-vline
WA_/SCWM/E1LTORI_STR-PICK_ALL sy-vline
WA_/SCWM/E1LTORI_STR-DSTGRP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.