ABAP Select data from SAP table /SCWM/DLV_HUGI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/DLV_HUGI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/DLV_HUGI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/DLV_HUGI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/DLV_HUGI TYPE STANDARD TABLE OF /SCWM/DLV_HUGI,
      WA_/SCWM/DLV_HUGI TYPE /SCWM/DLV_HUGI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/DLV_HUGI> TYPE /SCWM/DLV_HUGI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/DLV_HUGI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/DLV_HUGI
  INTO TABLE IT_/SCWM/DLV_HUGI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/DLV_HUGI
*  INTO TABLE @DATA(IT_/SCWM/DLV_HUGI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/DLV_HUGI INDEX 1 INTO DATA(WA_/SCWM/DLV_HUGI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/DLV_HUGI ASSIGNING </SCWM/DLV_HUGI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/DLV_HUGI>-MANDT = 1.
</SCWM/DLV_HUGI>-DOCID = 1.
</SCWM/DLV_HUGI>-HUIDENT = 1.
</SCWM/DLV_HUGI>-DOCCAT = 1.
</SCWM/DLV_HUGI>-LGNUM = 1.
ENDLOOP.

LOOP AT IT_/SCWM/DLV_HUGI INTO WA_/SCWM/DLV_HUGI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/DLV_HUGI-PMAT_GUID, sy-vline,
WA_/SCWM/DLV_HUGI-T_WEIGHT, sy-vline,
WA_/SCWM/DLV_HUGI-UNIT_TW, sy-vline,
WA_/SCWM/DLV_HUGI-T_VOLUME, sy-vline,
WA_/SCWM/DLV_HUGI-UNIT_TV, sy-vline,
WA_/SCWM/DLV_HUGI-T_CAPA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/DLV_HUGI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/DLV_HUGI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/DLV_HUGI INTO WA_/SCWM/DLV_HUGI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit HUID, internal->external for field HUIDENT CALL FUNCTION 'CONVERSION_EXIT_HUID_OUTPUT' EXPORTING input = WA_/SCWM/DLV_HUGI-HUIDENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/DLV_HUGI-HUIDENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MDLPD, internal->external for field PMAT_GUID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/DLV_HUGI-PMAT_GUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/DLV_HUGI-PMAT_GUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_TW CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/DLV_HUGI-UNIT_TW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/DLV_HUGI-UNIT_TW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_TV CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/DLV_HUGI-UNIT_TV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/DLV_HUGI-UNIT_TV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_LWH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/DLV_HUGI-UNIT_LWH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/DLV_HUGI-UNIT_LWH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_GW CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/DLV_HUGI-UNIT_GW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/DLV_HUGI-UNIT_GW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_GV CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/DLV_HUGI-UNIT_GV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/DLV_HUGI-UNIT_GV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_MAX_LWH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/DLV_HUGI-UNIT_MAX_LWH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/DLV_HUGI-UNIT_MAX_LWH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/DLV_HUGI_STR,
MANDT TYPE STRING,
DOCID TYPE STRING,
HUIDENT TYPE STRING,
DOCCAT TYPE STRING,
LGNUM TYPE STRING,
PMAT_GUID TYPE STRING,
T_WEIGHT TYPE STRING,
UNIT_TW TYPE STRING,
T_VOLUME TYPE STRING,
UNIT_TV TYPE STRING,
T_CAPA TYPE STRING,
LENGTH TYPE STRING,
WIDTH TYPE STRING,
HEIGHT TYPE STRING,
UNIT_LWH TYPE STRING,
CLOSED_PACKAGE TYPE STRING,
TARE_VAR TYPE STRING,
MAX_WEIGHT TYPE STRING,
UNIT_GW TYPE STRING,
MAX_VOLUME TYPE STRING,
UNIT_GV TYPE STRING,
MAX_CAPA TYPE STRING,
MAX_LENGTH TYPE STRING,
MAX_WIDTH TYPE STRING,
MAX_HEIGHT TYPE STRING,
UNIT_MAX_LWH TYPE STRING,
TOLW TYPE STRING,
TOLV TYPE STRING,
TOLC TYPE STRING,
LOGPOS TYPE STRING,
HUTYP TYPE STRING,
HUHDR_DUMMY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/DLV_HUGI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/DLV_HUGI_STR-MANDT sy-vline
WA_/SCWM/DLV_HUGI_STR-DOCID sy-vline
WA_/SCWM/DLV_HUGI_STR-HUIDENT sy-vline
WA_/SCWM/DLV_HUGI_STR-DOCCAT sy-vline
WA_/SCWM/DLV_HUGI_STR-LGNUM sy-vline
WA_/SCWM/DLV_HUGI_STR-PMAT_GUID sy-vline
WA_/SCWM/DLV_HUGI_STR-T_WEIGHT sy-vline
WA_/SCWM/DLV_HUGI_STR-UNIT_TW sy-vline
WA_/SCWM/DLV_HUGI_STR-T_VOLUME sy-vline
WA_/SCWM/DLV_HUGI_STR-UNIT_TV sy-vline
WA_/SCWM/DLV_HUGI_STR-T_CAPA sy-vline
WA_/SCWM/DLV_HUGI_STR-LENGTH sy-vline
WA_/SCWM/DLV_HUGI_STR-WIDTH sy-vline
WA_/SCWM/DLV_HUGI_STR-HEIGHT sy-vline
WA_/SCWM/DLV_HUGI_STR-UNIT_LWH sy-vline
WA_/SCWM/DLV_HUGI_STR-CLOSED_PACKAGE sy-vline
WA_/SCWM/DLV_HUGI_STR-TARE_VAR sy-vline
WA_/SCWM/DLV_HUGI_STR-MAX_WEIGHT sy-vline
WA_/SCWM/DLV_HUGI_STR-UNIT_GW sy-vline
WA_/SCWM/DLV_HUGI_STR-MAX_VOLUME sy-vline
WA_/SCWM/DLV_HUGI_STR-UNIT_GV sy-vline
WA_/SCWM/DLV_HUGI_STR-MAX_CAPA sy-vline
WA_/SCWM/DLV_HUGI_STR-MAX_LENGTH sy-vline
WA_/SCWM/DLV_HUGI_STR-MAX_WIDTH sy-vline
WA_/SCWM/DLV_HUGI_STR-MAX_HEIGHT sy-vline
WA_/SCWM/DLV_HUGI_STR-UNIT_MAX_LWH sy-vline
WA_/SCWM/DLV_HUGI_STR-TOLW sy-vline
WA_/SCWM/DLV_HUGI_STR-TOLV sy-vline
WA_/SCWM/DLV_HUGI_STR-TOLC sy-vline
WA_/SCWM/DLV_HUGI_STR-LOGPOS sy-vline
WA_/SCWM/DLV_HUGI_STR-HUTYP sy-vline
WA_/SCWM/DLV_HUGI_STR-HUHDR_DUMMY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.