ABAP Select data from SAP table /SCWM/BINMAT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCWM/BINMAT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCWM/BINMAT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCWM/BINMAT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCWM/BINMAT TYPE STANDARD TABLE OF /SCWM/BINMAT,
      WA_/SCWM/BINMAT TYPE /SCWM/BINMAT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCWM/BINMAT> TYPE /SCWM/BINMAT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCWM/BINMAT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCWM/BINMAT
  INTO TABLE IT_/SCWM/BINMAT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCWM/BINMAT
*  INTO TABLE @DATA(IT_/SCWM/BINMAT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCWM/BINMAT INDEX 1 INTO DATA(WA_/SCWM/BINMAT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCWM/BINMAT ASSIGNING </SCWM/BINMAT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCWM/BINMAT>-MANDT = 1.
</SCWM/BINMAT>-LGNUM = 1.
</SCWM/BINMAT>-MATID = 1.
</SCWM/BINMAT>-ENTITLED = 1.
</SCWM/BINMAT>-LGPLA = 1.
ENDLOOP.

LOOP AT IT_/SCWM/BINMAT INTO WA_/SCWM/BINMAT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCWM/BINMAT-LGTYP, sy-vline,
WA_/SCWM/BINMAT-OUTCON, sy-vline,
WA_/SCWM/BINMAT-DATOUT, sy-vline,
WA_/SCWM/BINMAT-MAXQTY, sy-vline,
WA_/SCWM/BINMAT-MAXQTY_UOM_DSP, sy-vline,
WA_/SCWM/BINMAT-MINQTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCWM/BINMAT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCWM/BINMAT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCWM/BINMAT INTO WA_/SCWM/BINMAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MDLPD, internal->external for field MATID CALL FUNCTION 'CONVERSION_EXIT_MDLPD_OUTPUT' EXPORTING input = WA_/SCWM/BINMAT-MATID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/BINMAT-MATID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENTITLED CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCWM/BINMAT-ENTITLED IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/BINMAT-ENTITLED.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MAXQTY_UOM_DSP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/BINMAT-MAXQTY_UOM_DSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/BINMAT-MAXQTY_UOM_DSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MINQTY_UOM_DSP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCWM/BINMAT-MINQTY_UOM_DSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/BINMAT-MINQTY_UOM_DSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCWM/BINMAT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/BINMAT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTWH, internal->external for field CREATED_AT CALL FUNCTION 'CONVERSION_EXIT_TSTWH_OUTPUT' EXPORTING input = WA_/SCWM/BINMAT-CREATED_AT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCWM/BINMAT-CREATED_AT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCWM/BINMAT_STR,
MANDT TYPE STRING,
LGNUM TYPE STRING,
MATID TYPE STRING,
ENTITLED TYPE STRING,
LGPLA TYPE STRING,
LGTYP TYPE STRING,
OUTCON TYPE STRING,
DATOUT TYPE STRING,
MAXQTY TYPE STRING,
MAXQTY_UOM_DSP TYPE STRING,
MINQTY TYPE STRING,
MINQTY_UOM_DSP TYPE STRING,
MATNR TYPE STRING,
RMMQTY_FIX TYPE STRING,
CREATED_AT TYPE STRING,
CREATED_BY TYPE STRING,
IMPROV_FIX TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCWM/BINMAT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCWM/BINMAT_STR-MANDT sy-vline
WA_/SCWM/BINMAT_STR-LGNUM sy-vline
WA_/SCWM/BINMAT_STR-MATID sy-vline
WA_/SCWM/BINMAT_STR-ENTITLED sy-vline
WA_/SCWM/BINMAT_STR-LGPLA sy-vline
WA_/SCWM/BINMAT_STR-LGTYP sy-vline
WA_/SCWM/BINMAT_STR-OUTCON sy-vline
WA_/SCWM/BINMAT_STR-DATOUT sy-vline
WA_/SCWM/BINMAT_STR-MAXQTY sy-vline
WA_/SCWM/BINMAT_STR-MAXQTY_UOM_DSP sy-vline
WA_/SCWM/BINMAT_STR-MINQTY sy-vline
WA_/SCWM/BINMAT_STR-MINQTY_UOM_DSP sy-vline
WA_/SCWM/BINMAT_STR-MATNR sy-vline
WA_/SCWM/BINMAT_STR-RMMQTY_FIX sy-vline
WA_/SCWM/BINMAT_STR-CREATED_AT sy-vline
WA_/SCWM/BINMAT_STR-CREATED_BY sy-vline
WA_/SCWM/BINMAT_STR-IMPROV_FIX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.