ABAP Select data from SAP table /SCMTMS/S_UIH_TCC_BASIC_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_UIH_TCC_BASIC_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_UIH_TCC_BASIC_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_UIH_TCC_BASIC_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_UIH_TCC_BASIC_DATA TYPE STANDARD TABLE OF /SCMTMS/S_UIH_TCC_BASIC_DATA,
      WA_/SCMTMS/S_UIH_TCC_BASIC_DATA TYPE /SCMTMS/S_UIH_TCC_BASIC_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_UIH_TCC_BASIC_DATA> TYPE /SCMTMS/S_UIH_TCC_BASIC_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_UIH_TCC_BASIC_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_UIH_TCC_BASIC_DATA
  INTO TABLE IT_/SCMTMS/S_UIH_TCC_BASIC_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_UIH_TCC_BASIC_DATA
*  INTO TABLE @DATA(IT_/SCMTMS/S_UIH_TCC_BASIC_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_UIH_TCC_BASIC_DATA INDEX 1 INTO DATA(WA_/SCMTMS/S_UIH_TCC_BASIC_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_UIH_TCC_BASIC_DATA ASSIGNING </SCMTMS/S_UIH_TCC_BASIC_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_UIH_TCC_BASIC_DATA>-KEY = 1.
</SCMTMS/S_UIH_TCC_BASIC_DATA>-PARENT_KEY = 1.
</SCMTMS/S_UIH_TCC_BASIC_DATA>-ROOT_KEY = 1.
</SCMTMS/S_UIH_TCC_BASIC_DATA>-TCCALCRESINS040 = 1.
</SCMTMS/S_UIH_TCC_BASIC_DATA>-LINENR = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_UIH_TCC_BASIC_DATA INTO WA_/SCMTMS/S_UIH_TCC_BASIC_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_UIH_TCC_BASIC_DATA-TCET084, sy-vline,
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA-RULE101, sy-vline,
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA-ROUND_RULE, sy-vline,
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA-REFTCCS098, sy-vline,
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA-CALC_REF_LINE_NO, sy-vline,
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA-CLCRESBAS036, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_UIH_TCC_BASIC_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_UIH_TCC_BASIC_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_UIH_TCC_BASIC_DATA INTO WA_/SCMTMS/S_UIH_TCC_BASIC_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LINENR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UIH_TCC_BASIC_DATA-LINENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UIH_TCC_BASIC_DATA-LINENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REFTCCS098 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UIH_TCC_BASIC_DATA-REFTCCS098 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UIH_TCC_BASIC_DATA-REFTCCS098.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CALC_REF_LINE_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UIH_TCC_BASIC_DATA-CALC_REF_LINE_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UIH_TCC_BASIC_DATA-CALC_REF_LINE_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR,
KEY TYPE STRING,
PARENT_KEY TYPE STRING,
ROOT_KEY TYPE STRING,
TCCALCRESINS040 TYPE STRING,
LINENR TYPE STRING,
TCET084 TYPE STRING,
RULE101 TYPE STRING,
ROUND_RULE TYPE STRING,
REFTCCS098 TYPE STRING,
CALC_REF_LINE_NO TYPE STRING,
CLCRESBAS036 TYPE STRING,
CLCRESBAS036_TXT TYPE STRING,
RULE096 TYPE STRING,
RULE113 TYPE STRING,
RULE096_TXT TYPE STRING,
CALC_METH_CODE TYPE STRING,
CALC_METH_NAME TYPE STRING,
ADJUST_PROFILE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-KEY sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-PARENT_KEY sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-ROOT_KEY sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-TCCALCRESINS040 sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-LINENR sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-TCET084 sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-RULE101 sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-ROUND_RULE sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-REFTCCS098 sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-CALC_REF_LINE_NO sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-CLCRESBAS036 sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-CLCRESBAS036_TXT sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-RULE096 sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-RULE113 sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-RULE096_TXT sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-CALC_METH_CODE sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-CALC_METH_NAME sy-vline
WA_/SCMTMS/S_UIH_TCC_BASIC_DATA_STR-ADJUST_PROFILE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.