ABAP Select data from SAP table /SCMTMS/S_UI_LSO_LOAD_PLAN into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_UI_LSO_LOAD_PLAN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_UI_LSO_LOAD_PLAN. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_UI_LSO_LOAD_PLAN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_UI_LSO_LOAD_PLAN TYPE STANDARD TABLE OF /SCMTMS/S_UI_LSO_LOAD_PLAN,
      WA_/SCMTMS/S_UI_LSO_LOAD_PLAN TYPE /SCMTMS/S_UI_LSO_LOAD_PLAN,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_UI_LSO_LOAD_PLAN> TYPE /SCMTMS/S_UI_LSO_LOAD_PLAN.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_UI_LSO_LOAD_PLAN.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_UI_LSO_LOAD_PLAN
  INTO TABLE IT_/SCMTMS/S_UI_LSO_LOAD_PLAN.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_UI_LSO_LOAD_PLAN
*  INTO TABLE @DATA(IT_/SCMTMS/S_UI_LSO_LOAD_PLAN2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_UI_LSO_LOAD_PLAN INDEX 1 INTO DATA(WA_/SCMTMS/S_UI_LSO_LOAD_PLAN2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_UI_LSO_LOAD_PLAN ASSIGNING </SCMTMS/S_UI_LSO_LOAD_PLAN>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_UI_LSO_LOAD_PLAN>-VEHICLE_ID = 1.
</SCMTMS/S_UI_LSO_LOAD_PLAN>-RES_CLASS = 1.
</SCMTMS/S_UI_LSO_LOAD_PLAN>-KEY = 1.
</SCMTMS/S_UI_LSO_LOAD_PLAN>-PARENT_KEY = 1.
</SCMTMS/S_UI_LSO_LOAD_PLAN>-ROOT_KEY = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_UI_LSO_LOAD_PLAN INTO WA_/SCMTMS/S_UI_LSO_LOAD_PLAN.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-IMAGE_SRC, sy-vline,
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-PLAN_STATUS, sy-vline,
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-ITEM_ID, sy-vline,
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-FU_ROOT_KEY, sy-vline,
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-FU_ROOT_ID, sy-vline,
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-TRQ_ROOT_KEY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_UI_LSO_LOAD_PLAN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_UI_LSO_LOAD_PLAN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_UI_LSO_LOAD_PLAN INTO WA_/SCMTMS/S_UI_LSO_LOAD_PLAN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ITEM_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-ITEM_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-ITEM_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FU_ROOT_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-FU_ROOT_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-FU_ROOT_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRQ_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-TRQ_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-TRQ_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEASUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-MEASUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-MEASUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-GRO_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-GRO_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-GRO_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-GRO_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_VOL_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-GRO_VOL_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-GRO_VOL_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_VOL_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-GRO_VOL_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-GRO_VOL_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MAX_TOP_LOAD_UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-MAX_TOP_LOAD_UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-MAX_TOP_LOAD_UOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PRODUCT_ID CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-PRODUCT_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-PRODUCT_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BASE_BTD_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-BASE_BTD_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-BASE_BTD_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BASE_BTD_ID_DLV CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-BASE_BTD_ID_DLV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-BASE_BTD_ID_DLV.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BASE_BTDITEM_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-BASE_BTDITEM_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_UI_LSO_LOAD_PLAN-BASE_BTDITEM_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR,
VEHICLE_ID TYPE STRING,
RES_CLASS TYPE STRING,
KEY TYPE STRING,
PARENT_KEY TYPE STRING,
ROOT_KEY TYPE STRING,
IMAGE_SRC TYPE STRING,
PLAN_STATUS TYPE STRING,
ITEM_ID TYPE STRING,
FU_ROOT_KEY TYPE STRING,
FU_ROOT_ID TYPE STRING,
TRQ_ROOT_KEY TYPE STRING,
TRQ_ID TYPE STRING,
TRQ_CAT TYPE STRING,
SOURCE_LOCATION TYPE STRING,
DESTINATION_LOCATION TYPE STRING,
ORIENTATION TYPE STRING,
POS_X TYPE STRING,
POS_Y TYPE STRING,
POS_Z TYPE STRING,
POS_ROW TYPE STRING,
POS_STACK TYPE STRING,
POS_LEVEL TYPE STRING,
POS_SPLIT_DECK TYPE STRING,
LOAD_SEQ TYPE STRING,
ORIENTATION_UI TYPE STRING,
POS_SPLIT_DECK_UI TYPE STRING,
LENGTH TYPE STRING,
WIDTH TYPE STRING,
HEIGHT TYPE STRING,
MEASUOM TYPE STRING,
GRO_WEI_VAL TYPE STRING,
GRO_WEI_UNI TYPE STRING,
GRO_VOL_VAL TYPE STRING,
GRO_VOL_UNI TYPE STRING,
MAX_TOP_LOAD TYPE STRING,
MAX_TOP_LOAD_UOM TYPE STRING,
PACKAGE_ID TYPE STRING,
PACKAGE_TCO TYPE STRING,
NON_STACKABLE TYPE STRING,
PRODUCT_ID TYPE STRING,
EXCLUDE TYPE STRING,
IMAGE_LEGEND TYPE STRING,
BASE_BTD_TCO TYPE STRING,
BASE_BTD_TCO_TXT TYPE STRING,
BASE_BTD_ID TYPE STRING,
BASE_BTD_TCO_DLV TYPE STRING,
BASE_BTD_TCO_DLV_TXT TYPE STRING,
BASE_BTD_ID_DLV TYPE STRING,
BASE_BTDITEM_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-VEHICLE_ID sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-RES_CLASS sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-KEY sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-PARENT_KEY sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-ROOT_KEY sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-IMAGE_SRC sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-PLAN_STATUS sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-ITEM_ID sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-FU_ROOT_KEY sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-FU_ROOT_ID sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-TRQ_ROOT_KEY sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-TRQ_ID sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-TRQ_CAT sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-SOURCE_LOCATION sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-DESTINATION_LOCATION sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-ORIENTATION sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-POS_X sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-POS_Y sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-POS_Z sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-POS_ROW sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-POS_STACK sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-POS_LEVEL sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-POS_SPLIT_DECK sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-LOAD_SEQ sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-ORIENTATION_UI sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-POS_SPLIT_DECK_UI sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-LENGTH sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-WIDTH sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-HEIGHT sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-MEASUOM sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-GRO_WEI_VAL sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-GRO_WEI_UNI sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-GRO_VOL_VAL sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-GRO_VOL_UNI sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-MAX_TOP_LOAD sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-MAX_TOP_LOAD_UOM sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-PACKAGE_ID sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-PACKAGE_TCO sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-NON_STACKABLE sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-PRODUCT_ID sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-EXCLUDE sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-IMAGE_LEGEND sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-BASE_BTD_TCO sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-BASE_BTD_TCO_TXT sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-BASE_BTD_ID sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-BASE_BTD_TCO_DLV sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-BASE_BTD_TCO_DLV_TXT sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-BASE_BTD_ID_DLV sy-vline
WA_/SCMTMS/S_UI_LSO_LOAD_PLAN_STR-BASE_BTDITEM_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.