ABAP Select data from SAP table /SCMTMS/S_TEND_SUBC_TEND_Q_RES into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_TEND_SUBC_TEND_Q_RES table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_TEND_SUBC_TEND_Q_RES. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_TEND_SUBC_TEND_Q_RES table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_TEND_SUBC_TEND_Q_RES TYPE STANDARD TABLE OF /SCMTMS/S_TEND_SUBC_TEND_Q_RES,
      WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES TYPE /SCMTMS/S_TEND_SUBC_TEND_Q_RES,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_TEND_SUBC_TEND_Q_RES> TYPE /SCMTMS/S_TEND_SUBC_TEND_Q_RES.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_TEND_SUBC_TEND_Q_RES.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_TEND_SUBC_TEND_Q_RES
  INTO TABLE IT_/SCMTMS/S_TEND_SUBC_TEND_Q_RES.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_TEND_SUBC_TEND_Q_RES
*  INTO TABLE @DATA(IT_/SCMTMS/S_TEND_SUBC_TEND_Q_RES2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_TEND_SUBC_TEND_Q_RES INDEX 1 INTO DATA(WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_TEND_SUBC_TEND_Q_RES ASSIGNING </SCMTMS/S_TEND_SUBC_TEND_Q_RES>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_TEND_SUBC_TEND_Q_RES>-DB_KEY = 1.
</SCMTMS/S_TEND_SUBC_TEND_Q_RES>-CREATED_ON = 1.
</SCMTMS/S_TEND_SUBC_TEND_Q_RES>-TOR_KEY = 1.
</SCMTMS/S_TEND_SUBC_TEND_Q_RES>-TOR_ID = 1.
</SCMTMS/S_TEND_SUBC_TEND_Q_RES>-TOR_CAT = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_TEND_SUBC_TEND_Q_RES INTO WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-TOR_TYPE, sy-vline,
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-TOR_PURCH_ORG_ID, sy-vline,
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-TOR_PURCH_GRP_ID, sy-vline,
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-TOR_EXEC_ORG_ID, sy-vline,
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-TOR_EXEC_GRP_ID, sy-vline,
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-TRMODCOD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_TEND_SUBC_TEND_Q_RES TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_TEND_SUBC_TEND_Q_RES INTO WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTLC, internal->external for field CREATED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-CREATED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-CREATED_ON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TOR_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-TOR_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-TOR_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit STAMP, internal->external for field START_DATETIME CALL FUNCTION 'CONVERSION_EXIT_STAMP_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-START_DATETIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-START_DATETIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit STAMP, internal->external for field EST_END_DATETIME CALL FUNCTION 'CONVERSION_EXIT_STAMP_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-EST_END_DATETIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-EST_END_DATETIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit STAMP, internal->external for field END_DATETIME CALL FUNCTION 'CONVERSION_EXIT_STAMP_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-END_DATETIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-END_DATETIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TSP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-TSP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-TSP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-GRO_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-GRO_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-GRO_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-GRO_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_VOL_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-GRO_VOL_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-GRO_VOL_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_VOL_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-GRO_VOL_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-GRO_VOL_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field NET_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-NET_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-NET_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NET_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-NET_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-NET_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUA_PCS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-QUA_PCS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-QUA_PCS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-QUA_PCS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-QUA_PCS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUA_PCS2_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-QUA_PCS2_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-QUA_PCS2_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS2_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-QUA_PCS2_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-QUA_PCS2_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field BASE_UOM_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-BASE_UOM_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-BASE_UOM_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASE_UOM_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-BASE_UOM_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-BASE_UOM_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field PKGUN_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-PKGUN_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-PKGUN_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PKGUN_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-PKGUN_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-PKGUN_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CONT_CNT_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-CONT_CNT_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-CONT_CNT_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CONT_CNT_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-CONT_CNT_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-CONT_CNT_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field DG_ADR_PTS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-DG_ADR_PTS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-DG_ADR_PTS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DG_ADR_PTS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-DG_ADR_PTS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-DG_ADR_PTS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ID004, internal->external for field FIRST_STOP_LOC_KEY CALL FUNCTION 'CONVERSION_EXIT_ID004_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-FIRST_STOP_LOC_KEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-FIRST_STOP_LOC_KEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ID004, internal->external for field LAST_STOP_LOC_KEY CALL FUNCTION 'CONVERSION_EXIT_ID004_OUTPUT' EXPORTING input = WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-LAST_STOP_LOC_KEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES-LAST_STOP_LOC_KEY.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR,
DB_KEY TYPE STRING,
CREATED_ON TYPE STRING,
TOR_KEY TYPE STRING,
TOR_ID TYPE STRING,
TOR_CAT TYPE STRING,
TOR_TYPE TYPE STRING,
TOR_PURCH_ORG_ID TYPE STRING,
TOR_PURCH_GRP_ID TYPE STRING,
TOR_EXEC_ORG_ID TYPE STRING,
TOR_EXEC_GRP_ID TYPE STRING,
TRMODCOD TYPE STRING,
RESP_PERSON TYPE STRING,
CONFIRMATION TYPE STRING,
SUBCONTRACTING TYPE STRING,
SUBM_PRICE_AMOUNT_SUBM_C TYPE STRING,
SUBM_PRICE_CURR_SUBM TYPE STRING,
SUBM_PRICE_SETBY TYPE STRING,
TEND_SEQ_NR TYPE STRING,
TEND_MANAGER TYPE STRING,
START_DATETIME TYPE STRING,
EST_END_DATETIME TYPE STRING,
END_DATETIME TYPE STRING,
TEND_PROCESS_RES TYPE STRING,
LIFECYCLE TYPE STRING,
STEP_SEQ_NR TYPE STRING,
TEND_TYPE TYPE STRING,
TSP TYPE STRING,
TSP_SET_BY TYPE STRING,
SENT_TEND_REQS TYPE STRING,
OPEN_TEND_REQS TYPE STRING,
ACC_TEND_RESPS TYPE STRING,
NACC_TEND_RESPS TYPE STRING,
REQ_RESP_STATUS TYPE STRING,
FIRST_STOP TYPE STRING,
LAST_STOP TYPE STRING,
MTR TYPE STRING,
FIRST_STOP_ACC_START TYPE STRING,
LAST_STOP_ACC_END TYPE STRING,
GRO_WEI_VAL TYPE STRING,
GRO_WEI_UNI TYPE STRING,
GRO_VOL_VAL TYPE STRING,
GRO_VOL_UNI TYPE STRING,
NET_WEI_VAL TYPE STRING,
NET_WEI_UNI TYPE STRING,
QUA_PCS_VAL TYPE STRING,
QUA_PCS_UNI TYPE STRING,
QUA_PCS2_VAL TYPE STRING,
QUA_PCS2_UNI TYPE STRING,
BASE_UOM_VAL TYPE STRING,
BASE_UOM_UNI TYPE STRING,
PKGUN_WEI_VAL TYPE STRING,
PKGUN_WEI_UNI TYPE STRING,
CONT_CNT_VAL TYPE STRING,
CONT_CNT_UNI TYPE STRING,
DG_ADR_PTS_VAL TYPE STRING,
DG_ADR_PTS_UNI TYPE STRING,
DUMMY TYPE STRING,
LABELTXT TYPE STRING,
FIRST_STOP_LOC_KEY TYPE STRING,
LAST_STOP_LOC_KEY TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-DB_KEY sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-CREATED_ON sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TOR_KEY sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TOR_ID sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TOR_CAT sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TOR_TYPE sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TOR_PURCH_ORG_ID sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TOR_PURCH_GRP_ID sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TOR_EXEC_ORG_ID sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TOR_EXEC_GRP_ID sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TRMODCOD sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-RESP_PERSON sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-CONFIRMATION sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-SUBCONTRACTING sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-SUBM_PRICE_AMOUNT_SUBM_C sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-SUBM_PRICE_CURR_SUBM sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-SUBM_PRICE_SETBY sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TEND_SEQ_NR sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TEND_MANAGER sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-START_DATETIME sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-EST_END_DATETIME sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-END_DATETIME sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TEND_PROCESS_RES sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-LIFECYCLE sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-STEP_SEQ_NR sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TEND_TYPE sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TSP sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-TSP_SET_BY sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-SENT_TEND_REQS sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-OPEN_TEND_REQS sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-ACC_TEND_RESPS sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-NACC_TEND_RESPS sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-REQ_RESP_STATUS sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-FIRST_STOP sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-LAST_STOP sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-MTR sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-FIRST_STOP_ACC_START sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-LAST_STOP_ACC_END sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-GRO_WEI_VAL sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-GRO_WEI_UNI sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-GRO_VOL_VAL sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-GRO_VOL_UNI sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-NET_WEI_VAL sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-NET_WEI_UNI sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-QUA_PCS_VAL sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-QUA_PCS_UNI sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-QUA_PCS2_VAL sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-QUA_PCS2_UNI sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-BASE_UOM_VAL sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-BASE_UOM_UNI sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-PKGUN_WEI_VAL sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-PKGUN_WEI_UNI sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-CONT_CNT_VAL sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-CONT_CNT_UNI sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-DG_ADR_PTS_VAL sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-DG_ADR_PTS_UNI sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-DUMMY sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-LABELTXT sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-FIRST_STOP_LOC_KEY sy-vline
WA_/SCMTMS/S_TEND_SUBC_TEND_Q_RES_STR-LAST_STOP_LOC_KEY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.