ABAP Select data from SAP table /SCMTMS/S_RES_LAB_ROOT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_RES_LAB_ROOT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_RES_LAB_ROOT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_RES_LAB_ROOT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_RES_LAB_ROOT TYPE STANDARD TABLE OF /SCMTMS/S_RES_LAB_ROOT,
      WA_/SCMTMS/S_RES_LAB_ROOT TYPE /SCMTMS/S_RES_LAB_ROOT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_RES_LAB_ROOT> TYPE /SCMTMS/S_RES_LAB_ROOT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_RES_LAB_ROOT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_RES_LAB_ROOT
  INTO TABLE IT_/SCMTMS/S_RES_LAB_ROOT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_RES_LAB_ROOT
*  INTO TABLE @DATA(IT_/SCMTMS/S_RES_LAB_ROOT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_RES_LAB_ROOT INDEX 1 INTO DATA(WA_/SCMTMS/S_RES_LAB_ROOT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_RES_LAB_ROOT ASSIGNING </SCMTMS/S_RES_LAB_ROOT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_RES_LAB_ROOT>-LABOURRES_ID = 1.
</SCMTMS/S_RES_LAB_ROOT>-LIFECYCLE_STATUS = 1.
</SCMTMS/S_RES_LAB_ROOT>-WORKCAL_CODE = 1.
</SCMTMS/S_RES_LAB_ROOT>-UUID004 = 1.
</SCMTMS/S_RES_LAB_ROOT>-LABOR_FACTOR = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_RES_LAB_ROOT INTO WA_/SCMTMS/S_RES_LAB_ROOT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_RES_LAB_ROOT-VALID_FROM, sy-vline,
WA_/SCMTMS/S_RES_LAB_ROOT-VALID_TO, sy-vline,
WA_/SCMTMS/S_RES_LAB_ROOT-TZONE, sy-vline,
WA_/SCMTMS/S_RES_LAB_ROOT-ACTIVE_VERSION, sy-vline,
WA_/SCMTMS/S_RES_LAB_ROOT-BPEXT, sy-vline,
WA_/SCMTMS/S_RES_LAB_ROOT-NAME_LAST, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_RES_LAB_ROOT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_RES_LAB_ROOT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_RES_LAB_ROOT INTO WA_/SCMTMS/S_RES_LAB_ROOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LABOURRES_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RES_LAB_ROOT-LABOURRES_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RES_LAB_ROOT-LABOURRES_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PERNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_RES_LAB_ROOT-PERNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_RES_LAB_ROOT-PERNO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_RES_LAB_ROOT_STR,
LABOURRES_ID TYPE STRING,
LIFECYCLE_STATUS TYPE STRING,
WORKCAL_CODE TYPE STRING,
UUID004 TYPE STRING,
LABOR_FACTOR TYPE STRING,
VALID_FROM TYPE STRING,
VALID_TO TYPE STRING,
TZONE TYPE STRING,
ACTIVE_VERSION TYPE STRING,
BPEXT TYPE STRING,
NAME_LAST TYPE STRING,
NAME_FIRST TYPE STRING,
BU_SORT1 TYPE STRING,
BU_SORT2 TYPE STRING,
XSEXM TYPE STRING,
XSEXF TYPE STRING,
NATIO TYPE STRING,
XSEXU TYPE STRING,
PERNO TYPE STRING,
DATETIME_CR TYPE STRING,
USER_ID_CR TYPE STRING,
DATETIME_CH TYPE STRING,
USER_ID_CH TYPE STRING,
XUBNAME TYPE STRING,
ADDRESSID TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_RES_LAB_ROOT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-LABOURRES_ID sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-LIFECYCLE_STATUS sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-WORKCAL_CODE sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-UUID004 sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-LABOR_FACTOR sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-VALID_FROM sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-VALID_TO sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-TZONE sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-ACTIVE_VERSION sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-BPEXT sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-NAME_LAST sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-NAME_FIRST sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-BU_SORT1 sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-BU_SORT2 sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-XSEXM sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-XSEXF sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-NATIO sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-XSEXU sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-PERNO sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-DATETIME_CR sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-USER_ID_CR sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-DATETIME_CH sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-USER_ID_CH sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-XUBNAME sy-vline
WA_/SCMTMS/S_RES_LAB_ROOT_STR-ADDRESSID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.