ABAP Select data from SAP table /SCMTMS/S_PLN_EX_FU into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_PLN_EX_FU table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_PLN_EX_FU. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_PLN_EX_FU table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_PLN_EX_FU TYPE STANDARD TABLE OF /SCMTMS/S_PLN_EX_FU,
      WA_/SCMTMS/S_PLN_EX_FU TYPE /SCMTMS/S_PLN_EX_FU,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_PLN_EX_FU> TYPE /SCMTMS/S_PLN_EX_FU.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_PLN_EX_FU.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_PLN_EX_FU
  INTO TABLE IT_/SCMTMS/S_PLN_EX_FU.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_PLN_EX_FU
*  INTO TABLE @DATA(IT_/SCMTMS/S_PLN_EX_FU2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_PLN_EX_FU INDEX 1 INTO DATA(WA_/SCMTMS/S_PLN_EX_FU2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_PLN_EX_FU ASSIGNING </SCMTMS/S_PLN_EX_FU>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_PLN_EX_FU>-FU_UUID = 1.
</SCMTMS/S_PLN_EX_FU>-FU_ID = 1.
</SCMTMS/S_PLN_EX_FU>-START_TIME = 1.
</SCMTMS/S_PLN_EX_FU>-FINISH_TIME = 1.
</SCMTMS/S_PLN_EX_FU>-CAT = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_PLN_EX_FU INTO WA_/SCMTMS/S_PLN_EX_FU.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_PLN_EX_FU-TYPE, sy-vline,
WA_/SCMTMS/S_PLN_EX_FU-NOTPERFCOST, sy-vline,
WA_/SCMTMS/S_PLN_EX_FU-EARLINESS, sy-vline,
WA_/SCMTMS/S_PLN_EX_FU-LATENESS, sy-vline,
WA_/SCMTMS/S_PLN_EX_FU-CONTEXT, sy-vline,
WA_/SCMTMS/S_PLN_EX_FU-RG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_PLN_EX_FU you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_PLN_EX_FU TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_PLN_EX_FU INTO WA_/SCMTMS/S_PLN_EX_FU. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit EXP01, internal->external for field FU_UUID CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-FU_UUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-FU_UUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FU_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-FU_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-FU_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field START_TIME CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-START_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-START_TIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field FINISH_TIME CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-FINISH_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-FINISH_TIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP03, internal->external for field NOTPERFCOST CALL FUNCTION 'CONVERSION_EXIT_EXP03_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-NOTPERFCOST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-NOTPERFCOST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP08, internal->external for field EARLINESS CALL FUNCTION 'CONVERSION_EXIT_EXP08_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-EARLINESS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-EARLINESS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP08, internal->external for field LATENESS CALL FUNCTION 'CONVERSION_EXIT_EXP08_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-LATENESS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-LATENESS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP01, internal->external for field SOURCE_LOC CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-SOURCE_LOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-SOURCE_LOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXP01, internal->external for field TARGET_LOC CALL FUNCTION 'CONVERSION_EXIT_EXP01_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-TARGET_LOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-TARGET_LOC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-GRO_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-GRO_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-GRO_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-GRO_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_VOL_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-GRO_VOL_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-GRO_VOL_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_VOL_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-GRO_VOL_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-GRO_VOL_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field NET_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-NET_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-NET_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NET_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-NET_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-NET_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUA_PCS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-QUA_PCS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-QUA_PCS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-QUA_PCS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-QUA_PCS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUA_PCS2_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-QUA_PCS2_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-QUA_PCS2_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS2_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-QUA_PCS2_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-QUA_PCS2_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field BASE_UOM_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-BASE_UOM_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-BASE_UOM_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASE_UOM_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-BASE_UOM_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-BASE_UOM_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field PKGUN_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-PKGUN_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-PKGUN_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PKGUN_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-PKGUN_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-PKGUN_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CONT_CNT_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-CONT_CNT_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-CONT_CNT_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CONT_CNT_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-CONT_CNT_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-CONT_CNT_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field DG_ADR_PTS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-DG_ADR_PTS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-DG_ADR_PTS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DG_ADR_PTS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-DG_ADR_PTS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-DG_ADR_PTS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field NORMLOADCONSVAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-NORMLOADCONSVAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-NORMLOADCONSVAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NORMLOADCONSUOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-NORMLOADCONSUOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-NORMLOADCONSUOM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field REQ_PU_FR CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-REQ_PU_FR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-REQ_PU_FR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field REQ_PU_TO CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-REQ_PU_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-REQ_PU_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field ACC_PU_FR CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-ACC_PU_FR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-ACC_PU_FR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field ACC_PU_TO CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-ACC_PU_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-ACC_PU_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field REQ_DL_FR CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-REQ_DL_FR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-REQ_DL_FR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field REQ_DL_TO CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-REQ_DL_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-REQ_DL_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field ACC_DL_FR CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-ACC_DL_FR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-ACC_DL_FR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTLC, internal->external for field ACC_DL_TO CALL FUNCTION 'CONVERSION_EXIT_TSTLC_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PLN_EX_FU-ACC_DL_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PLN_EX_FU-ACC_DL_TO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_PLN_EX_FU_STR,
FU_UUID TYPE STRING,
FU_ID TYPE STRING,
START_TIME TYPE STRING,
FINISH_TIME TYPE STRING,
CAT TYPE STRING,
TYPE TYPE STRING,
NOTPERFCOST TYPE STRING,
EARLINESS TYPE STRING,
LATENESS TYPE STRING,
CONTEXT TYPE STRING,
RG TYPE STRING,
DSO TYPE STRING,
SOURCE_LOC TYPE STRING,
TARGET_LOC TYPE STRING,
GRO_WEI_VAL TYPE STRING,
GRO_WEI_UNI TYPE STRING,
GRO_VOL_VAL TYPE STRING,
GRO_VOL_UNI TYPE STRING,
NET_WEI_VAL TYPE STRING,
NET_WEI_UNI TYPE STRING,
QUA_PCS_VAL TYPE STRING,
QUA_PCS_UNI TYPE STRING,
QUA_PCS2_VAL TYPE STRING,
QUA_PCS2_UNI TYPE STRING,
BASE_UOM_VAL TYPE STRING,
BASE_UOM_UNI TYPE STRING,
PKGUN_WEI_VAL TYPE STRING,
PKGUN_WEI_UNI TYPE STRING,
CONT_CNT_VAL TYPE STRING,
CONT_CNT_UNI TYPE STRING,
DG_ADR_PTS_VAL TYPE STRING,
DG_ADR_PTS_UNI TYPE STRING,
NORMLOADCONSVAL TYPE STRING,
NORMLOADCONSUOM TYPE STRING,
REQ_PU_FR TYPE STRING,
REQ_PU_TO TYPE STRING,
ACC_PU_FR TYPE STRING,
ACC_PU_TO TYPE STRING,
REQ_DL_FR TYPE STRING,
REQ_DL_TO TYPE STRING,
ACC_DL_FR TYPE STRING,
ACC_DL_TO TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_PLN_EX_FU_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-FU_UUID sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-FU_ID sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-START_TIME sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-FINISH_TIME sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-CAT sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-TYPE sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-NOTPERFCOST sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-EARLINESS sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-LATENESS sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-CONTEXT sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-RG sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-DSO sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-SOURCE_LOC sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-TARGET_LOC sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-GRO_WEI_VAL sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-GRO_WEI_UNI sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-GRO_VOL_VAL sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-GRO_VOL_UNI sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-NET_WEI_VAL sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-NET_WEI_UNI sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-QUA_PCS_VAL sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-QUA_PCS_UNI sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-QUA_PCS2_VAL sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-QUA_PCS2_UNI sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-BASE_UOM_VAL sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-BASE_UOM_UNI sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-PKGUN_WEI_VAL sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-PKGUN_WEI_UNI sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-CONT_CNT_VAL sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-CONT_CNT_UNI sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-DG_ADR_PTS_VAL sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-DG_ADR_PTS_UNI sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-NORMLOADCONSVAL sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-NORMLOADCONSUOM sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-REQ_PU_FR sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-REQ_PU_TO sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-ACC_PU_FR sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-ACC_PU_TO sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-REQ_DL_FR sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-REQ_DL_TO sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-ACC_DL_FR sy-vline
WA_/SCMTMS/S_PLN_EX_FU_STR-ACC_DL_TO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.