ABAP Select data from SAP table /SCMTMS/S_PL_SET_UPD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_PL_SET_UPD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_PL_SET_UPD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_PL_SET_UPD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_PL_SET_UPD TYPE STANDARD TABLE OF /SCMTMS/S_PL_SET_UPD,
      WA_/SCMTMS/S_PL_SET_UPD TYPE /SCMTMS/S_PL_SET_UPD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_PL_SET_UPD> TYPE /SCMTMS/S_PL_SET_UPD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_PL_SET_UPD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_PL_SET_UPD
  INTO TABLE IT_/SCMTMS/S_PL_SET_UPD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_PL_SET_UPD
*  INTO TABLE @DATA(IT_/SCMTMS/S_PL_SET_UPD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_PL_SET_UPD INDEX 1 INTO DATA(WA_/SCMTMS/S_PL_SET_UPD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_PL_SET_UPD ASSIGNING </SCMTMS/S_PL_SET_UPD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_PL_SET_UPD>-MANDT = 1.
</SCMTMS/S_PL_SET_UPD>-SETID = 1.
</SCMTMS/S_PL_SET_UPD>-CONTEXT = 1.
</SCMTMS/S_PL_SET_UPD>-USERID = 1.
</SCMTMS/S_PL_SET_UPD>-DESCRIPTION = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_PL_SET_UPD INTO WA_/SCMTMS/S_PL_SET_UPD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_PL_SET_UPD-REQ_PROFILE, sy-vline,
WA_/SCMTMS/S_PL_SET_UPD-TU_PROFILE, sy-vline,
WA_/SCMTMS/S_PL_SET_UPD-PLN_PROFILE, sy-vline,
WA_/SCMTMS/S_PL_SET_UPD-CAPA_PROFILE, sy-vline,
WA_/SCMTMS/S_PL_SET_UPD-TOR_PROFILE, sy-vline,
WA_/SCMTMS/S_PL_SET_UPD-FB_PROFILE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_PL_SET_UPD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_PL_SET_UPD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_PL_SET_UPD INTO WA_/SCMTMS/S_PL_SET_UPD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field REQ_PROFILE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PL_SET_UPD-REQ_PROFILE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PL_SET_UPD-REQ_PROFILE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TU_PROFILE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PL_SET_UPD-TU_PROFILE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PL_SET_UPD-TU_PROFILE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLN_PROFILE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PL_SET_UPD-PLN_PROFILE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PL_SET_UPD-PLN_PROFILE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CAPA_PROFILE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PL_SET_UPD-CAPA_PROFILE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PL_SET_UPD-CAPA_PROFILE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TOR_PROFILE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PL_SET_UPD-TOR_PROFILE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PL_SET_UPD-TOR_PROFILE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FB_PROFILE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PL_SET_UPD-FB_PROFILE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PL_SET_UPD-FB_PROFILE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INC_PROFILE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PL_SET_UPD-INC_PROFILE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PL_SET_UPD-INC_PROFILE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TSPS_SETTING CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PL_SET_UPD-TSPS_SETTING IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PL_SET_UPD-TSPS_SETTING.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DLV_PROFILE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMTMS/S_PL_SET_UPD-DLV_PROFILE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_PL_SET_UPD-DLV_PROFILE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_PL_SET_UPD_STR,
MANDT TYPE STRING,
SETID TYPE STRING,
CONTEXT TYPE STRING,
USERID TYPE STRING,
DESCRIPTION TYPE STRING,
REQ_PROFILE TYPE STRING,
TU_PROFILE TYPE STRING,
PLN_PROFILE TYPE STRING,
CAPA_PROFILE TYPE STRING,
TOR_PROFILE TYPE STRING,
FB_PROFILE TYPE STRING,
INC_PROFILE TYPE STRING,
TSPS_SETTING TYPE STRING,
DLV_PROFILE TYPE STRING,
PC_LAYOUT TYPE STRING,
RESULT_LAYOUT TYPE STRING,
LAST_USAGE TYPE STRING,
COUNTER TYPE STRING,
REQ_COUNTER TYPE STRING,
DEFAULT_SET TYPE STRING,
JOB_NUMBER TYPE STRING,
JOB_NAME TYPE STRING,
JOB_STATUS TYPE STRING,
UPDATE_IND TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_PL_SET_UPD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-MANDT sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-SETID sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-CONTEXT sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-USERID sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-DESCRIPTION sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-REQ_PROFILE sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-TU_PROFILE sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-PLN_PROFILE sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-CAPA_PROFILE sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-TOR_PROFILE sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-FB_PROFILE sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-INC_PROFILE sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-TSPS_SETTING sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-DLV_PROFILE sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-PC_LAYOUT sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-RESULT_LAYOUT sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-LAST_USAGE sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-COUNTER sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-REQ_COUNTER sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-DEFAULT_SET sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-JOB_NUMBER sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-JOB_NAME sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-JOB_STATUS sy-vline
WA_/SCMTMS/S_PL_SET_UPD_STR-UPDATE_IND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.