ABAP Select data from SAP table /SCMTMS/S_CFIR_BOOK_ITM_PRINT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMTMS/S_CFIR_BOOK_ITM_PRINT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMTMS/S_CFIR_BOOK_ITM_PRINT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMTMS/S_CFIR_BOOK_ITM_PRINT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMTMS/S_CFIR_BOOK_ITM_PRINT TYPE STANDARD TABLE OF /SCMTMS/S_CFIR_BOOK_ITM_PRINT,
      WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT TYPE /SCMTMS/S_CFIR_BOOK_ITM_PRINT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMTMS/S_CFIR_BOOK_ITM_PRINT> TYPE /SCMTMS/S_CFIR_BOOK_ITM_PRINT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMTMS/S_CFIR_BOOK_ITM_PRINT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMTMS/S_CFIR_BOOK_ITM_PRINT
  INTO TABLE IT_/SCMTMS/S_CFIR_BOOK_ITM_PRINT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMTMS/S_CFIR_BOOK_ITM_PRINT
*  INTO TABLE @DATA(IT_/SCMTMS/S_CFIR_BOOK_ITM_PRINT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMTMS/S_CFIR_BOOK_ITM_PRINT INDEX 1 INTO DATA(WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMTMS/S_CFIR_BOOK_ITM_PRINT ASSIGNING </SCMTMS/S_CFIR_BOOK_ITM_PRINT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMTMS/S_CFIR_BOOK_ITM_PRINT>-TURES_ID = 1.
</SCMTMS/S_CFIR_BOOK_ITM_PRINT>-TURES_RCO = 1.
</SCMTMS/S_CFIR_BOOK_ITM_PRINT>-TURES_CAT = 1.
</SCMTMS/S_CFIR_BOOK_ITM_PRINT>-TURES_CAT_DESC = 1.
</SCMTMS/S_CFIR_BOOK_ITM_PRINT>-TYPE_CODE = 1.
ENDLOOP.

LOOP AT IT_/SCMTMS/S_CFIR_BOOK_ITM_PRINT INTO WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-LANGU, sy-vline,
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-DESCRIPTION_S, sy-vline,
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-GRO_WEI_VAL, sy-vline,
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-GRO_WEI_UNI, sy-vline,
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-GRO_VOL_VAL, sy-vline,
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-GRO_VOL_UNI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMTMS/S_CFIR_BOOK_ITM_PRINT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMTMS/S_CFIR_BOOK_ITM_PRINT INTO WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit QTYRN, internal->external for field GRO_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-GRO_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-GRO_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-GRO_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-GRO_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field GRO_VOL_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-GRO_VOL_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-GRO_VOL_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field GRO_VOL_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-GRO_VOL_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-GRO_VOL_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field NET_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-NET_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-NET_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field NET_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-NET_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-NET_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUA_PCS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-QUA_PCS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-QUA_PCS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-QUA_PCS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-QUA_PCS_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field QUA_PCS2_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-QUA_PCS2_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-QUA_PCS2_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field QUA_PCS2_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-QUA_PCS2_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-QUA_PCS2_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field BASE_UOM_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-BASE_UOM_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-BASE_UOM_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASE_UOM_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-BASE_UOM_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-BASE_UOM_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field PKGUN_WEI_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-PKGUN_WEI_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-PKGUN_WEI_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field PKGUN_WEI_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-PKGUN_WEI_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-PKGUN_WEI_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field CONT_CNT_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-CONT_CNT_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-CONT_CNT_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field CONT_CNT_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-CONT_CNT_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-CONT_CNT_UNI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit QTYRN, internal->external for field DG_ADR_PTS_VAL CALL FUNCTION 'CONVERSION_EXIT_QTYRN_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-DG_ADR_PTS_VAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-DG_ADR_PTS_VAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DG_ADR_PTS_UNI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-DG_ADR_PTS_UNI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT-DG_ADR_PTS_UNI.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR,
TURES_ID TYPE STRING,
TURES_RCO TYPE STRING,
TURES_CAT TYPE STRING,
TURES_CAT_DESC TYPE STRING,
TYPE_CODE TYPE STRING,
LANGU TYPE STRING,
DESCRIPTION_S TYPE STRING,
GRO_WEI_VAL TYPE STRING,
GRO_WEI_UNI TYPE STRING,
GRO_VOL_VAL TYPE STRING,
GRO_VOL_UNI TYPE STRING,
NET_WEI_VAL TYPE STRING,
NET_WEI_UNI TYPE STRING,
QUA_PCS_VAL TYPE STRING,
QUA_PCS_UNI TYPE STRING,
QUA_PCS2_VAL TYPE STRING,
QUA_PCS2_UNI TYPE STRING,
BASE_UOM_VAL TYPE STRING,
BASE_UOM_UNI TYPE STRING,
PKGUN_WEI_VAL TYPE STRING,
PKGUN_WEI_UNI TYPE STRING,
CONT_CNT_VAL TYPE STRING,
CONT_CNT_UNI TYPE STRING,
DG_ADR_PTS_VAL TYPE STRING,
DG_ADR_PTS_UNI TYPE STRING,
PLATENUMBER TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-TURES_ID sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-TURES_RCO sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-TURES_CAT sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-TURES_CAT_DESC sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-TYPE_CODE sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-LANGU sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-DESCRIPTION_S sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-GRO_WEI_VAL sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-GRO_WEI_UNI sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-GRO_VOL_VAL sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-GRO_VOL_UNI sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-NET_WEI_VAL sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-NET_WEI_UNI sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-QUA_PCS_VAL sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-QUA_PCS_UNI sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-QUA_PCS2_VAL sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-QUA_PCS2_UNI sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-BASE_UOM_VAL sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-BASE_UOM_UNI sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-PKGUN_WEI_VAL sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-PKGUN_WEI_UNI sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-CONT_CNT_VAL sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-CONT_CNT_UNI sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-DG_ADR_PTS_VAL sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-DG_ADR_PTS_UNI sy-vline
WA_/SCMTMS/S_CFIR_BOOK_ITM_PRINT_STR-PLATENUMBER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.