ABAP Select data from SAP table /SCMB/P5561 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP /SCMB/P5561 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to /SCMB/P5561. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the /SCMB/P5561 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_/SCMB/P5561 TYPE STANDARD TABLE OF /SCMB/P5561,
      WA_/SCMB/P5561 TYPE /SCMB/P5561,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: </SCMB/P5561> TYPE /SCMB/P5561.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_/SCMB/P5561.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM /SCMB/P5561
  INTO TABLE IT_/SCMB/P5561.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM /SCMB/P5561
*  INTO TABLE @DATA(IT_/SCMB/P55612).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_/SCMB/P5561 INDEX 1 INTO DATA(WA_/SCMB/P55612).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_/SCMB/P5561 ASSIGNING </SCMB/P5561>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
</SCMB/P5561>-MANDT = 1.
</SCMB/P5561>-PLVAR = 1.
</SCMB/P5561>-OTYPE = 1.
</SCMB/P5561>-OBJID = 1.
</SCMB/P5561>-INFTY = 1.
ENDLOOP.

LOOP AT IT_/SCMB/P5561 INTO WA_/SCMB/P5561.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_/SCMB/P5561-SUBTY, sy-vline,
WA_/SCMB/P5561-ISTAT, sy-vline,
WA_/SCMB/P5561-PRIOX, sy-vline,
WA_/SCMB/P5561-BEGDA, sy-vline,
WA_/SCMB/P5561-ENDDA, sy-vline,
WA_/SCMB/P5561-VARYF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_/SCMB/P5561 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_/SCMB/P5561 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_/SCMB/P5561 INTO WA_/SCMB/P5561. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PARTNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_/SCMB/P5561-PARTNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_/SCMB/P5561-PARTNER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_/SCMB/P5561_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
ISTAT TYPE STRING,
PRIOX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
REASN TYPE STRING,
HISTO TYPE STRING,
ITXNR TYPE STRING,
EXTERNAL_ID TYPE STRING,
LOGQS TYPE STRING,
LOGQS_ID TYPE STRING,
FUNCTION TYPE STRING,
ROLE TYPE STRING,
PARTNER TYPE STRING,
LOCAL_CURR TYPE STRING,
INTRA_SETTLEMENT TYPE STRING,
PROFILE_ID TYPE STRING,
PURCH_CALC_PROF TYPE STRING,
EMBEDDED_LSP TYPE STRING,
REF_EXTERNAL_ID TYPE STRING,
SHORT TYPE STRING,
STEXT TYPE STRING,
GDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_/SCMB/P5561_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_/SCMB/P5561_STR-MANDT sy-vline
WA_/SCMB/P5561_STR-PLVAR sy-vline
WA_/SCMB/P5561_STR-OTYPE sy-vline
WA_/SCMB/P5561_STR-OBJID sy-vline
WA_/SCMB/P5561_STR-INFTY sy-vline
WA_/SCMB/P5561_STR-SUBTY sy-vline
WA_/SCMB/P5561_STR-ISTAT sy-vline
WA_/SCMB/P5561_STR-PRIOX sy-vline
WA_/SCMB/P5561_STR-BEGDA sy-vline
WA_/SCMB/P5561_STR-ENDDA sy-vline
WA_/SCMB/P5561_STR-VARYF sy-vline
WA_/SCMB/P5561_STR-SEQNR sy-vline
WA_/SCMB/P5561_STR-AEDTM sy-vline
WA_/SCMB/P5561_STR-UNAME sy-vline
WA_/SCMB/P5561_STR-REASN sy-vline
WA_/SCMB/P5561_STR-HISTO sy-vline
WA_/SCMB/P5561_STR-ITXNR sy-vline
WA_/SCMB/P5561_STR-EXTERNAL_ID sy-vline
WA_/SCMB/P5561_STR-LOGQS sy-vline
WA_/SCMB/P5561_STR-LOGQS_ID sy-vline
WA_/SCMB/P5561_STR-FUNCTION sy-vline
WA_/SCMB/P5561_STR-ROLE sy-vline
WA_/SCMB/P5561_STR-PARTNER sy-vline
WA_/SCMB/P5561_STR-LOCAL_CURR sy-vline
WA_/SCMB/P5561_STR-INTRA_SETTLEMENT sy-vline
WA_/SCMB/P5561_STR-PROFILE_ID sy-vline
WA_/SCMB/P5561_STR-PURCH_CALC_PROF sy-vline
WA_/SCMB/P5561_STR-EMBEDDED_LSP sy-vline
WA_/SCMB/P5561_STR-REF_EXTERNAL_ID sy-vline
WA_/SCMB/P5561_STR-SHORT sy-vline
WA_/SCMB/P5561_STR-STEXT sy-vline
WA_/SCMB/P5561_STR-GDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.